Honeywell Pro 3000 Series Non-Programmable Digital Thermostat Installation Manual

Honeywell Pro 3000 Series Non-Programmable Digital Thermostat Installation Manual

Download Honeywell Pro 3000 Series Installation Manual (PDF)

Table of Contents

What the Manual Covers

Page 1 labels the product a “Non-Programmable Digital Thermostat” from the “PRO 3000 Series” and lists two models: “TH3110D1008” and “TH3210D1004”. To find yours, “Turn thermostat over to find model number and date code.”

Page 8 carries the colophon: “© 2020 Resideo Technologies, Inc. All rights reserved.” It also adds, “The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.”

The English text runs pages 1–8 of a 24-page trilingual PDF; French (pages 9–16) and Spanish (pages 17–24) mirror the same layout. Nothing here programs a schedule.

Wallplate Mounting

Page 1 opens with, “Remove the wallplate from the thermostat by pulling from the bottom, then follow directions below for mounting.” The four steps are literal:

  • “Pull wires through wire hole.”
  • “Position wallplate on wall, level and mark hole positions with pencil.”
  • “Drill holes at marked positions as shown below, then tap in supplied wall anchors.”
  • “Place wallplate over anchors, insert and tighten mounting screws.”

Two drill bit sizes decide the job: 3/16-inch for drywall, 7/32-inch for plaster. The manual also asks you to tap the supplied anchors into the drilled holes before setting the wallplate back over them.

Pro 3000 Series Terminal Designations

Page 2 lists terminals per model. Read them once; every wiring row on page 3 references them by letter.

TH3110D terminals (page 2)
TerminalManual definition
Rc“24 Vac power from cooling transformer”
R“24 Vac power from heating transformer”
C“24 Vac common. For 2 transformer systems, use common wire from cooling transformer.”
W“Heat relay”
Y“Compressor contactor”
G“Fan relay”
O“Changeover valve energized in cooling”
B“Changeover valve energized in heating”

The TH3210D list on the same page keeps C, O, B, G, Y as printed, drops W, splits R into a single “24 Vac power” source (no Rc), and adds three posts unique to that board: Aux “Auxiliary heat relay”, E “Emergency heat relay”, and L “Sends output when set to Em. Heat”. TH3110D installation covers every conventional row; TH3210D is the two-stage heat-pump variant with auxiliary and emergency heat.

Wiring for Conventional Systems

Page 3 lays out seven configurations for Pro 3000 thermostat wiring; five are conventional systems on the TH3110D board. The bracketed numbers in the tables below refer to the nine notes collected in the Wiring Notes section. TH3110D installation covers all five conventional rows.

Conventional system configurations (page 3)
ConfigurationTerminals usedNotes
1H/1C System (1 transformer), TH3110DRc · R · W · Y · G · CR [R+Rc joined by jumper]; [1, 3]
1H/1C System (2 transformers), TH3110DRc · R · W · Y · G · C[1, 2, 3, 4]
Heat Only System, TH3110DRc · R · W · CR [R+Rc joined by jumper]; [1, 3]
Heat Only System with Fan, TH3110DRc · R · W · G · CR [R+Rc joined by jumper]; [1, 3]
Cool Only System, TH3110DRc · R · Y · G · CR [R+Rc joined by jumper]; [1, 3]

Wire gauge comes before the diagrams: “Wire specifications: Use 18- to 22-gauge thermostat wire. Shielded cable is not required.”

TH3210D Heat Pump Wiring

Page 3 also covers two heat pump configurations. The TH3110D handles 1H/1C heat pumps; TH3210D heat pump wiring is required for two-stage auxiliary heat.

Heat pump configurations (page 3)
ConfigurationTerminals usedNotes
1H/1C Heat Pump, TH3110DRc · R · W · Y · G · C · O · BR [R+Rc joined by jumper]; W [W+Y joined by jumper]; [1, 3, 5, 6, 7]
2H/1C Heat Pump, TH3210DR · Y · Aux · E · G · C · O · B · L[1, 3, 5, 8, 9]

On the 1H/1C row, W is not wired on its own — the manual prints it as a field jumper to Y. Pro 3000 Series terminal designations matter here: misreading W for Y2, or O for B, is the most common miswire.

Wiring Notes

Page 3 closes with nine numbered notes keyed to the diagrams:

  1. “Power supply. Provide disconnect means and overload protection as required.”
  2. “Remove jumper for 2-transformer systems.”
  3. “Optional 24 Vac common connection.”
  4. “Common connection must come from cooling transformer.”
  5. “Use either O or B terminals for changeover valve.”
  6. “Use a small piece of wire (not supplied) to connect W and Y terminals.”
  7. “Set fan operation switch to Heat Pump (see page 5) and configure system type for heat pump (see page 6).”
  8. “L terminal sends a continuous output when thermostat is set to Em. Heat. Connect to Honeywell Home zoning panels to switch the panel to Emergency Heat.”
  9. “Install field jumper between Aux and E if there is no emergency heat relay.”

Thermostat Mounting and the Fan Operation Switch

Page 4 walks you back onto the wallplate: “Align the 4 tabs on the wallplate with corresponding slots on the back of the thermostat.” then “Push gently until the thermostat snaps in place.” and finally “Plug wall opening with non- flammable insulation.”

The same page then sets the fan operation switch on the TH3110D board. Gas or oil installs leave it in the factory position: “For gas or oil heating systems, leave the fan operation switch in this factory-set position.” Heat pump or electric heat flips it: “Change the switch to this setting for heat pump or electric heat systems.”

Installer Setup

Page 5 lists seven Pro 3000 installer setup functions on the non-programmable board. To enter setup, press and hold both arrow keys until the display changes; the up key advances the function, the down key changes the setting, and both together exit and save.

Installer setup functions (page 5)
Func.SettingOptions
1System type (TH3110D only)0 Gas, oil or electric heat with air conditioning · 1 Heat pump (5 minute compressor off time in heating and cooling)
5Heating cycle rate (CPH), TH3110D only5 gas or oil under 90% · 1 steam or gravity · 3 hot water or 90%+ · 9 electric · others 2, 4, 6, 7, 8, 10, 11, 12
6Auxiliary heat cycle rate (CPH), TH3210D onlySame option list as function 5
8Emergency heat cycle rate (CPH), TH3210D only9 electric emergency · 1 steam or gravity · 3 hot water or 90%+ · 5 gas or oil under 90% · others 2, 4, 6, 7, 8, 10, 11, 12
9Compressor cycle rate (CPH)3 Recommended for most compressors · other options 1, 2, 4, 5, 6
14Temperature display0 Fahrenheit · 1 Celsius
15Compressor protection5 Five-minute compressor off time · other options 0, 1, 2, 3, 4

Function 15 has a plain-language description on the same page: “Forces the compressor to wait a few minutes before restarting, to prevent damage. During the wait time, the message Cool On or Heat On (heat pumps only) will flash on the display.”

Because the PDF’s text layer drops bold, every option above is listed unmarked. The printed manual marks factory settings in bold on page 5; consult the paper copy before changing anything.

Installer System Test

Page 6 walks the installer through a four-number system test. To start, “Set SYSTEM switch to Heat.” and press the down arrow to bring each system online against the table below; press again until systems turn off. The TH3210D adds one more pass: “Set SYSTEM switch to Em Heat and repeat steps 2-3 above (TH3210D only).” Cool repeats the same cycle. Holding both arrow keys together ends the test at any time.

System test numbers and status codes (page 6)
TestSystemStatus codes
10Heating system0 Heat and fan off · 1 Heat turns on · 2 Auxiliary heat turns on (TH3210D only)
20Emergency heat0 Heat and fan off · 1 Heat and fan turn on · 2 Auxiliary heat turns on
30Cooling system0 Compressor and fan off · 1 Compressor and fan turn on
70Thermostat information (for reference only)71–72 software revision major / minor · 73–74 configuration identification major / minor · 75–76 production date code week / year

Page 8 pairs the test with a warning: “CAUTION: EQUIPMENT DAMAGE HAZARD Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.”

Troubleshooting

Page 7 is a six-symptom checklist. “Most problems can be corrected quickly and easily.”

  • Blank display — check the circuit breaker, the power switch at the heating and cooling system, the furnace door, and that “fresh AA alkaline batteries are correctly installed (see page 2)”.
  • Heat or cool does not respond — set SYSTEM to the matching mode, verify the setpoint is above (heat) or below (cool) the indoor temperature, then “Wait 5 minutes for the system to respond.”
  • Setpoint does not change — the manual prints the accepted range as Heat “40° to 90°F (4.5° to 32°C)” and Cool “50° to 99°F (10° to 37°C)”.
  • Cool On or Heat On flashes — “Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor.”
  • Cool On absent — set the System switch to Cool, set the temperature below current room temperature.
  • Heat On absent — set the System switch to Heat, set the temperature above current room temperature.

Specifications

Page 7’s specifications block prints these ratings:

  • Temperature ranges: Heat 40° to 90°F (4.5° to 32°C); Cool 50° to 99°F (10° to 37°C)
  • Operating ambient: 32° to 120°F (0° to 48.9°C)
  • Shipping: -20° to 120°F (-28.9° to 48.9°C)
  • Humidity: 5% to 90% (non-condensing)
  • Dimensions: 3-13/16 in. H x 5-3/8 in. W x 1-1/4 in. D (97 mm H x 137 mm W x 32 mm D)
  • Input: 24 V~ @ 60 Hz, 1.0 A
Electrical ratings (page 7)
SystemVoltage (50/60 Hz)Running current
Heat (1st stage)20-30 Vac0.02-1.0 A
(Powerpile)750 mV DC100 mA DC
Emergency heat20-30 Vac0.02-1.0 A
Auxiliary heat20-30 Vac0.02-1.0 A
Cooling20-30 Vac0.02-1.0 A

Safety Notices

Page 8 stacks four cautions at the foot of the guide. “CAUTION: ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation.” The equipment-damage caution quoted above appears again here, alongside the mercury and e-waste notices that follow.

Two more notices round out the safety page: “If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash.” — the mercury notice — and “The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers.” — the electronic waste notice.

Support contact on the same page: “For assistance with this product, please visit customer.resideo.com. Or call Customer Care toll-free at 1-800-468-1502.”

FAQ

Which Pro 3000 model is right for my system?

TH3110D1008 covers conventional 1H/1C and 2H/2C installations plus 1H/1C heat pumps using its W and Y terminals. TH3210D1004 adds a dedicated Aux relay and E (emergency heat) terminal for 2H/1C heat pumps with a backup heat source.

Do I need a C wire on the Pro 3000?

The manual describes C as “Optional 24 Vac common connection”, with two-transformer systems using the cooling side: “For 2 transformer systems, use common wire from cooling transformer.” Batteries provide primary or backup power if C is not run.

What does the L terminal do on the TH3210D?

Per wiring note [8], the L post is used for Honeywell Home zoning panels: it sends a continuous output when the thermostat is set to Em Heat, which lets the panel switch to emergency-heat operation.

How do I set up a heat pump on the Pro 3000?

Two switches cooperate. First, set the physical fan operation switch on the TH3110D board to Heat Pump (page 4). Then, in Pro 3000 installer setup, set function 1 to 1 so the thermostat knows to run 5-minute compressor off time in both heating and cooling.

Why won’t my thermostat turn on?

Work through the page 7 checklist. “Display is blank” starts with the circuit breaker and the “power switch at heating & cooling system”. Confirm the furnace door is shut, then check that “fresh AA alkaline batteries are correctly installed”.

What temperature range can the Pro 3000 be set to?

Heat settings run 40° to 90°F (4.5° to 32°C). Cool settings run 50° to 99°F (10° to 37°C). Setpoints outside these bounds simply won’t accept a change.

Honeywell CT2800 Programmable Thermostat installation instructions

Honeywell CT2800 Programmable Thermostat installation instructions 

These notes follow the official Honeywell CT2800 Programmable Thermostat installation instructions (document 69-1638) so you can install, wire and program this weekday/weekend thermostat without guessing. The CT2800 is a 5-2 day, single-stage model, so the compatibility check and the DIP-switch setup matter. Every step below is taken from the printed document and labeled with its step number, and the PDF is linked here. Work with the power off and confirm the manual against your own system.

Download the official Honeywell CT2800 Installation Instructions (PDF)

Table of Contents

What the CT2800 Is

The CT2800 is a digital, wall-mounted programmable thermostat for a low-voltage (20 to 30 VAC) central heating and/or cooling system. Its key traits, straight from the document:

  • Weekday/Weekend (5-2 day) programming. One schedule for Monday to Friday, a separate one for Saturday and Sunday.
  • Up to four periods a day. Wake, Leave, Return and Sleep on weekdays; Wake and Sleep on weekends.
  • Single-stage heat and/or cool. It controls one stage of heating and one stage of cooling.
  • Two AA alkaline batteries. They power the clock and program.

Step 0: Check Compatibility First

The instructions open with a compatibility chart, because the CT2800 only fits certain systems. If yours is not listed as compatible, the chart names an alternate Honeywell model instead (Step “Verify You Have Correct Thermostat”).

Heating/Cooling systemCompatible?Alternate model
Conventional: single-stage warm-air furnace or hot waterYes—
Electric baseboard heat (120 to 240V)NoCT1950 (240V)
Steam boiler with radiatorsNoCT3600
Heat pump (no auxiliary/backup heat)NoCT3600
Multistage heat pump (with auxiliary/backup heat)NoCT3611
Multistage conventional (more than one stage)NoSee a contractor

Read this carefully: the CT2800 is not for heat pumps, steam, line-voltage electric baseboard, or multistage systems. If a label such as O, B, W2, H2 or Y2 is on your old thermostat, the instructions stop the installation and point you to an alternate model.

Before You Start

  • You need two AA alkaline batteries (Honeywell recommends Energizer), a screwdriver, a drill with a 3/16-inch or 7/32-inch bit, a pencil, a level, wire cutter/stripper, and electrical tape.
  • Confirm your heating and cooling equipment works first. A pre-existing problem can outlive the new thermostat.
  • Do not run cooling when the outdoor temperature is below 50°F (10°C), which can damage the compressor.
  • If your old thermostat contains mercury in a sealed tube, the document’s Mercury Notice requires you to recycle it, not bin it.

Installing the Thermostat

The document walks through numbered steps. In order:

  1. Step 2, remove the old thermostat. Turn off power at the furnace or the fuse/circuit-breaker panel. Take off the old cover and mounting plate without disconnecting the wires, then label each wire with the terminal letter (not the color). If the old unit has a C/C1 clock wire, six or more wires, only three wires, five wires, or unused extra wires, jump to the special-wiring notes first.
  2. Step 3, mount the plate. Separate the plate from the body with a coin, level it, mark the holes, and drill (3/16-inch for drywall, 7/32-inch for plaster or wood). Tap in the anchors for drywall, feed the wires through, and tighten the screws.
  3. Step 4, set it for your heating type. Use the FUEL switch on the back for F (gas/oil) or E (electric), then set DIP switches 1 and 2 per the heating-system table (default 1-On/2-On is for a standard warm-air gas/oil furnace; 1-Off/2-On for high-efficiency or hot water; 1-On/2-Off for electric). Turn DIP switch 3 to Off if you want Celsius instead of Fahrenheit.
  4. Step 6, mount. Line up the top tabs and snap the bottom in.
  5. Step 7, batteries. With the System switch Off, insert two AA alkaline batteries with correct polarity. The display lights up with a flashing time, meaning it is ready to program.

Wiring the CT2800

Step 5 matches each labeled wire to the terminal with the same letter on the back of the thermostat. The CT2800 uses five terminals.

TerminalWhat it does
RPower (heating transformer)
RcPower for cooling
WHeat call
YCooling call
GFan

The instructions also state:

  • No C wire. The CT2800 does not use the C terminal. Tape off any unused or clock (C/C1) wires so they cannot touch.
  • R / Rc jumper. A metal jumper sits between R and Rc out of the box. Leave it for a single-transformer system; remove it only for a five-wire system, then run each power wire to its own terminal.
  • Old labels that differ. The cross-reference table maps old terminals such as R, RH, 4 or V to the new R; Rc or R to Rc; W, W1 or H to W; Y or Y1 to Y; and G or F to G. A wire on O or B, or on W2, H2 or Y2, means stop and use another model.

Programming the Weekday/Weekend Schedule

Heating and cooling are programmed separately. Set the System switch to Heat for the heating schedule, then to Cool for the cooling schedule. To start, press SCHEDULE; use the Time buttons to set a period’s time and the Temp buttons to set its temperature, then advance to the next period. Set the weekday periods (Wake, Leave, Return, Sleep), then the weekend (Wake, Sleep), and press RUN to finish.

The document supplies suggested values. For heating: Wake 6:00 AM 70°F (21°C), Leave 8:00 AM 62°F (16.5°C), Return 6:00 PM 70°F, Sleep 10:00 PM 62°F. For cooling: Wake 6:00 AM 78°F (25.5°C), Leave 8:00 AM 85°F (29.5°C), Return 6:00 PM 78°F, Sleep 10:00 PM 82°F (28°C).

A few rules from the text: setpoints cannot go below 45°F (7°C) or above 88°F (31°C); if you skip programming it, the thermostat runs heating at 68°F (20°C) and cooling at 78°F (26°C) around the clock; and an unprogrammed weekend keeps the weekday Sleep temperature until Monday’s Wake.

Controls and Overrides

  • System switch. Cool, Off or Heat.
  • Fan switch. Auto runs the fan only during heating or cooling; On runs it continuously.
  • Temporary override. Press Temp warmer or cooler; a TEMPORARY arrow shows and the change lasts until the next period.
  • Permanent hold. Press HOLD; “HLd” appears and the temperature is held until you cancel with RUN. Use it for a vacation.
  • Check programs. Press SCHEDULE repeatedly to review times and temperatures; press RUN to resume.

The display shows a SYSTEM ON arrow whenever the thermostat is calling for heating or cooling.

In Case of Difficulty

This is the document’s own “If… Then…” list. It is short and specific, so read it before deciding the thermostat is defective.

IfThen (what the manual says)
Display does not come onConfirm fresh batteries are installed correctly; if not, set System to Off, insert the batteries backward for 5 to 10 seconds, then reinstall them the right way.
Flashing “bAt Lo”Batteries are low. Replace them; if it continues, repeat the backward-insert reset.
Setpoint stops at 45°F or 88°FYou hit the programming limit; the range is 45°F to 88°F (7–31°C).
Temperature changes at the wrong timeRecheck that period’s AM/PM, and the current day and time.
Heat or cool will not startSet the System switch correctly, check the fuse/breaker and connections, replace batteries if blank, and allow the built-in cooling delay (about 5 to 10 minutes) before the compressor starts.
Furnace short-cyclesAdjust the anticipator screws on the back of the thermostat.
Displayed room temperature looks off by about 1°Seal the wall hole to stop drafts; small differences are normal and can last up to 30 minutes during recovery.

Specifications

  • Programming: Weekday/Weekend (5-2 day); up to four weekday periods and two weekend periods.
  • System control: Single-stage heat and/or cool.
  • Voltage: 20 to 30 VAC low-voltage systems.
  • Setpoint range while programming: 45°F to 88°F (7°C to 31°C).
  • Unprogrammed default: heat 68°F (20°C), cool 78°F (26°C).
  • Cooling delay: built-in, about 5 to 10 minutes.
  • Power: two AA alkaline batteries.
  • Terminals: R, Rc, W, Y, G; C is not used.
  • Not compatible with: heat pumps, steam, multistage systems, and 120/240V electric baseboard.
  • Warranty: 1-year limited (excludes battery); Honeywell Customer Care 1-800-468-1502.

FAQ

How long is the CT2800 installation?

The document lists seven steps: prepare, remove the old unit, mount the plate, set the fuel and DIP switches, wire, mount the body, and install the batteries, then program the schedule.

Which terminals does the CT2800 use?

R, Rc, W, Y and G. It does not use a C wire, and a pre-installed jumper links R and Rc unless you have a five-wire system.

Can I install the CT2800 on a heat pump?

No. Its compatibility chart lists heat pumps, steam, multistage systems and 120/240V electric baseboard as not compatible, and points to models such as the CT3600 instead.

What do the DIP switches do?

DIP switches 1 and 2 set the heating-system type and the FUEL switch sets gas/oil (F) or electric (E). DIP switch 3 changes the display between Fahrenheit and Celsius.

What happens if I never program it?

It runs a fixed default: heating at 68°F (20°C) and cooling at 78°F (26°C) all day, per the instructions.

Honeywell FocusPRO TH5000 Series Installation Manual

Honeywell FocusPRO TH5000 Series Installation Manual

This Honeywell FocusPRO TH5000 Series Installation Manual guide is for the technician with a non-programmable FocusPRO on the bench and a cable of unknown parentage coming out of the wall. Every terminal list, wiring note, setup function and rating below is quoted from the guide, with the page number attached.

It is eight English pages long and assumes you already know what a transformer does. What you get is a model-to-system map, fourteen wiring configurations, twelve numbered notes and an installer setup table. Read it as a lookup sheet, not a tutorial.

Download Honeywell FocusPRO TH5000 Series Installation Manual (PDF)

Table of Contents

Models and System Types

Page 1 labels the product a “Non-Programmable Digital Thermostat” and names its audience: “Must be installed by a trained, experienced technician”. The warning that follows is why you read the pages — “Failure to follow these instructions can damage the product or cause a hazardous condition.”

The footer document id is 69-1922EFS—03, and page 8 carries “© 2020 Resideo Technologies, Inc. All rights reserved.” — the series is sold through Resideo.

“This manual covers the following models”, and the split is by staging capacity rather than features:

  • “TH5110D: For 1 Heat/1 Cool systems”
  • “TH5220D: For up to 2 Heat/2 Cool systems”
  • “TH5320U: For up to 3 Heat/2 Cool systems (Remove battery holder to find model number)”

Shaded areas in the wiring pages “apply only to TH5320U/TH5220D or as otherwise noted”, so the model decides which rows are live. For FocusPRO TH5110D installation the board carries only Rc, Y, W, G, R and C.

Six system types are in scope: “Gas, oil, or electric heat with air conditioning”, “Warm air, hot water, high-efficiency furnaces, heat pumps, steam, gravity”, “Heat only — two-wire systems, three-wire zone valves (Series 20), and normally open zone valves”, then “Heat only with fan”, “Cool only” and “750 mV heating systems”.

Before You Install

Page 2 leads with a “CAUTION: ELECTRICAL HAZARD” that “Can cause electrical shock or equipment damage. Disconnect power before beginning installation.” The mercury notice covers whatever you just removed: “If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash.”

Wallplate work is “Separate wallplate from thermostat.”, then “Mount wallplate as shown below.”, with hole sizes that depend on the wall: “Drill 3/16” holes for drywall. Drill 7/32” holes for plaster.”

Power options come from page 3: “Connect C for primary AC power (optional if batteries are installed).”, “Insert batteries for primary or backup power.” and “Remove factory-installed jumper only for two-transformer systems.” Page 5 closes the mechanical job — align the four wallplate tabs, “push gently until the thermostat snaps in place.”, then “Plug wall opening with non-flammable insulation.”

Terminal Designations

Page 3 defines the terminals twice: conventional, then heat pump.

Conventional terminals (page 3)
TerminalManual definition
Rc“24VAC power from cooling transformer”
R“24VAC power from heating transformer”
W / W2“Heat relay (stage 1)” / “Heat relay (stage 2)”
Y / Y2“Compressor contactor (stage 1)” / “Compressor contactor (stage 2)”
G“Fan relay”
C“24VAC common. For 2 transformer systems, use common wire from cooling transformer.”

The heat pump list keeps those Rc, R, G and C definitions, calls Y simply “Compressor contactor”, and replaces the heat relays with O/B “Changeover valve” plus Aux “Auxiliary heat relay*”, E “Emergency heat relay*” and L “Sends output when set to Em. Heat”. The asterisk reads “*Aux and E terminals combined on TH5320U only.”

Conventional Wiring Diagrams

Page 4 is the TH5000 series wiring diagram for conventional equipment: nine configurations. Wire gauge comes first — “Use 18- to 22-gauge thermostat wire. Shielded cable is not required.” Every single-transformer row prints Rc “Power [1]” with R “[R+Rc joined by jumper]”; the two-transformer rows print Rc “Power (cooling transformer) [1, 2]” with R “Power (heating transformer) [1, 2]”. W, W2, Y, Y2 and G take their page 3 definitions, C is “24VAC common” plus its note, and exceptions go in the last column.

Conventional system configurations (page 4)
ConfigurationTerminalsCommon note and exceptions
1H/1C System (1 transformer)Rc R Y C W GC [3]
1H/1C System (2 transformers)Rc R Y C W GC [3, 4]
2H/2C System (1 transformer) [6]Rc R Y C W G W2 Y2C [3]
2H/2C System (2 transformers) [6]Rc R Y C W G W2 Y2C [3, 4]
Heat-only SystemRc R C WC [3]
Heat-only System with FanRc R C W GC [3]
Heat-only System (Series 20) [5]Rc R Y C WR “Series 20 valve terminal “R” [1]”; Y “Series 20 valve terminal “W””; W “Series 20 valve terminal “B””
Heat-only System (normally open zone valve) [5]Rc R Y CR “Power [1]”; Y “Normally open zone valve”
Cool-only SystemRc R Y C GY “Compressor contactor”

Notes [2] to [7], [11] and [12] sit at the foot of page 4 and read as instructions.

Wiring notes (page 4)
NoteText
[2]“Remove jumper for 2-transformer systems.”
[3]“Optional 24VAC common connection.”
[4]“Common connection must come from cooling transformer.”
[5]“In Installer Setup, set system type to Heat Only.”
[6]“In Installer Setup, set system type to 2Heat/2Cool Conventional.”
[7]“In Installer Setup, set changeover valve to O or B.”
[11]“L terminal sends a continuous output when thermostat is set to Em. Heat. Connect to zoning panels to switch the panel to Emergency Heat.”
[12]“Install field jumper between Aux and E if there is no emergency heat relay.”

Notes [8] to [10] are the heat pump equivalents, each starting “In Installer Setup, set system type to” followed by 2Heat/1Cool, 2Heat/2Cool or 3Heat/2Cool Heat Pump. On a TH5220D 2 heat/2 cool wiring job note [6] is not optional; the system type is what picks the output logic.

Heat Pump Wiring Diagrams

Page 5 says “See [notes] on page 4.” Its five configurations use O/B for the changeover valve, which is why note [7] exists, and all keep the same Rc “Power [1]”, R “[R+Rc joined by jumper]”, Y “Compressor contactor”, C “24VAC common [3]”, O/B “Changeover valve [7]” and G “Fan relay” lines. L always “Sends output when set to Em. Heat [11]”, and the table lists only what each row adds. This is the TH5320U heat pump wiring page for three-stage jobs.

Heat pump configurations (page 5)
ConfigurationTerminals added to the shared sixTheir connections
1H/1C Heat Pump Systemnone—
2H/1C Heat Pump System (TH5220D only) [8]Aux, E, LAux “Auxiliary heat relay [12]”; E “Emergency heat relay [12]”
2H/1C Heat Pump System (TH5320U only) [8]Aux/E, LAux/E “Auxiliary/Emergency heat relay”
2H/2C Heat Pump System (TH5320U only) [9]Y2, LY2 “Compressor contactor (stage 2)”
3H/2C Heat Pump System (TH5320U only) [10]Aux/E, Y2, LAux/E “Auxiliary/Emergency heat relay”; Y2 “Compressor contactor (stage 2)”

Installer Setup Functions

Installer setup is how the FocusPRO TH5000 installer setup list matches the board to the equipment you wired. Page 6 starts it by holding the down arrow key with FAN “until the display changes.” Inside the menu, “Press NEXT to advance to the next function. Press DONE to exit and save settings.” Its own purpose line covers preference too: “customize feature operation as desired.”

The header reads “Settings & options (factory default in bold)”. Bold does not survive text extraction, so options below are listed in print order and left unmarked; check your paper copy. Function 1, system type, comes first.

Setup function 1 — system type (page 6)
ValueOption text
0“1 heat/1 cool conventional”
1“1 heat/1 cool heat pump (no aux. heat)”
2“Heat only — 2-wire systems, 3-wire zone valves (Series 20), and normally open zone valves”
3“Heat only with fan”
4“Cool only”
5“2 heat/1 cool heat pump (with aux. heat)”
6“2 heat/2 cool conventional”
7“2 heat/1 cool conventional”
8“1 heat/2 cool conventional”
9“2 heat/2 cool heat pump (no aux. heat) – TH5320U only”
10“3 heat/2 cool heat pump (with aux. heat) – TH5320U only”

Functions 2, 3 and 12 set changeover and fan behaviour. Function 2 offers “Changeover valve (O/B terminal energized in cooling)” and “Changeover valve (O/B terminal energized in heating)”, which is note [7] in the flesh. Function 3 offers “Gas or oil furnace — equipment controls fan in heating” and “Electric furnace — thermostat controls fan in heating”. Function 12 offers “Manual changeover (Heat/Cool/Off)”, auto changeover, or “Auto changeover only (Auto)”.

Functions 5 to 8 set heating cycle rates: stage 1 heat, “Stage 2 heat cycle rate/Auxiliary heat cycle rate (CPH)”, auxiliary heat (marked “Only TH5320U for 3H/2C Heat Pumps”) and emergency heat. Functions 5 to 7 share these option texts: “For gas or oil furnaces of less than 90% efficiency”, “For steam or gravity systems”, “For hot water systems & furnaces of over 90% efficiency” and “For electric furnaces”; function 8 swaps the last for “For electric emergency heat”.

Functions 9 and 10, the compressor rates, offer “Recommended for most compressors”, and the footnotes allow “Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH”.

The rest are display and limits: 14 selects “Fahrenheit” or “Celsius”; 15 sets the “Five-minute compressor off time”; 26 is auxiliary heat control; 27 and 28 are the range stops, “Max. heat temperature setting is 90 °F (32 °C)” and “Min. cool temperature setting is 50 °F (10 °C)”. Page 8 expands function 26: Comfort means “The thermostat will prioritize comfort over economy”, while Economy means “The thermostat will attempt to reach the temperature setting without activating the auxiliary heat.”

Installer System Test

The test runs from page 7, where “Press NEXT to advance to next test. Press DONE to terminate system test.” The caution is why you do not run it casually: “Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly”.

Tests are 10 heating, 20 emergency heat, 30 cooling and 40 fan; status 0 turns each off, status 1 runs “Stage 1 heat turns on. Fan turns on if Setup Function 1 is set to 1, 5, 9 or 10 OR Setup Function 3 is set to 1”, and the top stage on a heat pump is “Stage 3 heat turns on – TH5320U only”.

Specifications and Parts

The TH5000 series specifications sit on page 8 with the part list, prefaced by “Please contact your distributor to order replacement parts.” Cover plates are for the wall you uncovered — “Use to cover marks left by old thermostats.”

Battery holders are 50000951-001 (TH5110D) and 50007072-001 (TH5320U/TH5220D); cover plate assemblies are 50001137-001 and 50002883-001, also sold in 12-packs as 50007297-001 and 50007298-001.

Specifications (page 8)
ItemValue
Temperature rangesHeat: “40° to 90°F (4.5° to 32°C)”; Cool: “50° to 99°F (10° to 37°C)”
Operating ambient temperature“32° to 120°F (0° to 48.9°C)”
Shipping / humidity“-20° to 120°F”; “5% to 90% (non-condensing)”
DimensionsTH5220D “91 mm H x 147 mm W x 38 mm D”; TH5110D “86 mm H x 114 mm W x 33 mm D”
Electrical ratings, WHeating, “20-30 Vac”, “0.02-1.0 A (Powerpile)”; “750 mV DC”, “100 mA DC”
Electrical ratings, W2“(Aux) Heating”, “20-30 Vac”, “0.02-0.5 A”
Electrical ratings, Y and Y2Cooling, “20-30 Vac”, “0.02-1.0 A”
Electrical ratings, G, O/B, LFan / changeover / output, “20-30 Vac”, “0.02-0.5 A”
Electrical ratings, EEmergency heat, “20-30 Vac”, “0.02-1.0 A”

Page 8 closes with an electronic waste notice: “The product should not be disposed of with other household waste.” It gives no dimensions for the TH5320U, and it never mentions Wi-Fi or a program schedule in these eight pages.

FAQ

Which FocusPRO model do I need for two heating and two cooling stages?

Either larger board — “TH5220D: For up to 2 Heat/2 Cool systems”, or the TH5320U for three heat stages. The TH5110D has no W2 or Y2.

Do I have to connect a C wire?

No. “Connect C for primary AC power (optional if batteries are installed).”, and note [3] calls it an “Optional 24VAC common connection.”

When does the factory jumper between R and Rc come off?

Only on two-transformer jobs: “Remove jumper for 2-transformer systems.” There note [4] makes the common mandatory — “Common connection must come from cooling transformer.”

How is a Series 20 zone valve wired?

R, Y and W go to the valve’s R, W and B terminals, jumper left in place. Note [5]: “In Installer Setup, set system type to Heat Only.”

My heat pump’s auxiliary and emergency heat share one relay. Now what?

Note [12]: “Install field jumper between Aux and E if there is no emergency heat relay.” On the TH5320U they are already one terminal.

Honeywell CT3200 programmable thermostat Owner's Manual

Honeywell CT3200 programmable thermostat Owner’s Manual

This page summarizes the Honeywell CT3200 programmable thermostat Owner’s Manual (Owner’s Guide 69-1631) so you can install, program and fix this weekday/weekend thermostat without hunting through the PDF. The CT3200 is a 5-2 day programmable model for a single-stage heating and/or cooling system, and it is not the same as a 7-day thermostat. Every step below is drawn from the official document and noted with its section, and the manual PDF is linked here. Check it against your own system before you touch any wiring.

Download Honeywell CT3200 Owner’s Manual (PDF)

Table of Contents

What the CT3200 Is

The CT3200 is a digital, wall-mounted, low-voltage (20 to 30 VAC) programmable thermostat for a home’s heating and/or cooling system. Honeywell’s own description of it:

  • Weekday/Weekend (5-2 day) programming. One schedule for Monday to Friday and a separate one for Saturday and Sunday.
  • Four periods per day. Wake, Leave, Return and Sleep, each with its own temperature.
  • Heat and/or Cool control. It runs a single stage of heating and a single stage of cooling.
  • Two AA alkaline batteries. They back up the clock and program; the unit is powered by your low-voltage system.

Because it is a single-stage thermostat, it is not for multistage or variable-speed systems. Honeywell’s compatibility table lists alternate models if yours does not fit.

Is the CT3200 Right for Your System?

The Owner’s Guide starts with a compatibility check, because a programmable thermostat only works on the systems it is designed for (Step 1: Identify your system). It suits conventional 24-volt systems, including:

  • Single-stage warm-air furnace, with or without central air conditioning.
  • Hot-water or steam heat with a single stage.
  • Central cooling on a matching 24V system.
  • Heat pumps with single-stage heating and no electric auxiliary heat.

The guide then calls out cases that need attention before you install (Special wiring): a three-wire heating-only system, five-wire systems, and leftover wires not connected to the old thermostat. If your setup matches one of those, follow the guide’s special instructions or call a heating contractor; do not guess at the terminals.

To confirm the CT3200 is a fit, use the manual’s compatibility table. If the table points to a different model for your system, do not install this one.

Before You Install

The manual’s installation sequence begins with safety. Follow it in order (Step 1 and Step 2):

  1. Turn off power to the heating/cooling system at the furnace switch or the fuse/circuit-breaker panel.
  2. Remove the old thermostat’s cover and mounting plate without disconnecting the wires.
  3. Inspect the wiring. If the old thermostat has a C or C1 terminal wire, six or more wires, exactly three wires, five wires, or loose unused wires, stop and use the guide’s special-wiring instructions.
  4. Label each wire with the letter of the terminal it connects to on the old thermostat, using the enclosed labels. Label by terminal letter, not by wire color.

If your old thermostat contains mercury, the guide requires you to recycle it rather than place it in household trash (Mercury Notice).

Wiring the CT3200

The CT3200 has five terminals and does not use C. The table matches the manual’s wiring diagram (Step 7). Connect each labeled wire to the terminal with the same letter.

Terminal What it does
R 24V power for heating
Rc 24V power for cooling
W Heat call
Y Cool call
G Fan

The guide also notes:

  • C terminal. This thermostat does not use the C wiring terminal. If a C or C1 wire is present, tape it off and keep it clear of the new unit.
  • R/Rc jumper. A metal jumper is pre-installed between R and Rc. On a single-transformer system leave it; on a five-wire system (separate heating and cooling power), remove the jumper and run each power wire to its own terminal.
  • Old terminals that do not match. The guide includes a cross-reference table so wires from old terminals such as R, Rh, 4 or V map correctly to the new R and Rc. Use that table instead of assuming.

Programming the Weekday/Weekend Schedule

The CT3200 stores two schedules: a weekday set (Monday to Friday) and a weekend set (Saturday and Sunday), each with four periods. Heating and cooling are programmed separately, so set the System switch to Heat for the heating program and Cool for the cooling program. The general flow from the guide is:

  1. Press PROGRAM to start, then advance to the period you want (Wake, then Leave, Return and Sleep).
  2. Set the period’s time, then set its temperature.
  3. Repeat for each period. When a period is left blank, the thermostat uses the previous period’s temperature.
  4. Move between the weekday and weekend schedules. Once the first schedule is set, the guide lets you copy it to the next day or period to save time.
  5. Press RUN to save and return to normal operation.

The guide prints suggested start times and temperatures. For cooling they are Wake 6:00 AM 78°F (25.5°C), Leave 8:00 AM 85°F (29.5°C), Return 6:00 PM 78°F (25.5°C) and Sleep 10:00 PM 82°F (28°C); a parallel table gives the heating suggestions. Shift the numbers to your own day.

Controls You Use Every Day

  • System switch. Set to Heat, Cool or Off.
  • Fan switch. Set to Auto (fan runs only during heating or cooling) or On (fan runs continuously).
  • Raised or lowered temperature. Press the up/down arrows to change the current setting; this places the thermostat in a temporary hold until the next scheduled period, then the program resumes.
  • Permanent hold. To keep a temperature indefinitely, press and hold as the guide describes; press RUN to return to the schedule.
  • Check programs. Press PROGRAM repeatedly to review the times and temperatures you set; press RUN when done.

When the thermostat is actively calling for heating or cooling, the display shows a SYSTEM ON arrow.

Resetting the Thermostat

For a blank or confused display, the guide’s FAQ gives a reset rather than a button combination: set the System switch to Off, remove the batteries, then insert them backward (reversed polarity) for five to ten seconds and reinstall them the correct way. The display should come back on and you will need to set the time, day and schedule again. This is the manual’s stated reset method for this model.

Troubleshooting (From the Manual)

This is the “If… Then…” list from the guide’s Frequently Asked Questions (pp.22–23). Run through it before assuming the thermostat is bad.

Problem What the manual says to do
Display does not come on Make sure the batteries are fresh and installed correctly; if not, use the reversed-battery reset.
“bAt Lo” flashes Batteries are low. Replace them; if it still appears, do the reversed-battery reset.
Setpoint will not go below 45°F (7°C) or above 88°F (31°C) You have reached the programming limit; the range is 45°F to 88°F.
Temperature changes at the wrong times Check the AM/PM and the day/time for that period and reprogram if needed.
Heat does not come on Set System to Heat; check the fuse/breaker and connections; if blank or “bAt Lo”, replace batteries; allow time for the furnace to start.
Cool does not come on Set System to Cool; check fuse/breaker and connections; the thermostat has a built-in delay, so allow 5 to 10 minutes before the AC starts.
House too warm or too cool Press RUN/PROGRAM to check the current setpoint and change it if needed.
Furnace short-cycles Adjust the anticipator screws on the back of the thermostat (heat anticipator per the guide).
Display differs from setting by more than about 1° Seal the wall wire hole to stop drafts; some difference is normal, and during recovery setting and room temperature can differ for up to 30 minutes.

Specifications

  • Programming: Weekday/Weekend (5-2 day), four periods per day (Wake, Leave, Return, Sleep).
  • System control: Single-stage heat and/or cool; 24V low-voltage systems (20 to 30 VAC).
  • Setpoint range while programming: 45°F to 88°F (7°C to 31°C).
  • Cooling delay: built-in compressor protection of about 5 to 10 minutes.
  • Power: System-powered; two AA alkaline batteries back up clock and program.
  • Terminals: R, Rc, W, Y, G; C is not used.
  • Not compatible with: multistage or variable-speed systems, and millivolt (750 mV) gas-fire systems unless the compatibility table says otherwise.
  • Warranty: 1-year limited (excludes battery). Honeywell Customer Care 1-800-468-1502.

For exact dimensions and mounting, use the manual; they are not printed as a spec in the Owner’s Guide.

FAQ

Is the CT3200 a 7-day programmable thermostat?

No. It is a weekday/weekend (5-2 day) model: one schedule for Monday to Friday and a separate one for the weekend, with four periods each day.

Does the CT3200 need a C wire?

No. The guide states this thermostat does not use the C terminal. If a C or C1 wire is present, tape it off.

How many batteries does it use?

Two AA alkaline batteries. They preserve the clock and program. A flashing “bAt Lo” means they are low.

How do I reset a CT3200 with a blank display?

Set the System switch to Off, take out the batteries, insert them backward for five to ten seconds, then reinstall them the correct way and reset the time, day and schedule.

Why is the air conditioner slow to start?

The CT3200 has a built-in compressor delay; the manual tells you to allow 5 to 10 minutes after changing the setting before the cooling starts.

What temperature range can I set while programming?

Between 45°F (7°C) and 88°F (31°C); the display will not go beyond those limits during setup.

Honeywell TH8321WF1001 Wi-Fi VisionPRO thermostat User Guide

Honeywell TH8321WF1001 Wi-Fi VisionPRO thermostat User Guide

This Honeywell TH8321WF1001 Wi-Fi VisionPRO Thermostat User Guide is for the owner with the touchscreen already on the wall and a router it has never met. Every step, screen message and menu list below is quoted from the guide itself, with its page number attached.

The cover calls it the “Wi-Fi VisionPRO” 8000 User Guide, footer id 33-00066EFS—01. The file runs 156 pages because it is trilingual; the English section is pages 1 to 52. If you came looking for how to connect Honeywell VisionPro thermostat to Wi-Fi, that procedure starts on guide page 5.

Download Honeywell TH8321WF1001 Wi-Fi VisionPRO Thermostat User Guide (PDF)

Table of Contents

What the Thermostat Is For

Page 1 opens with six capabilities. You can “Connect to the Internet to monitor and control your heating/cooling system”, “View and change your heating/cooling system settings”, “View and set temperature and schedules”, “Receive alerts via email and get automatic upgrades”, “View outdoor temperature and humidity”, and “Download the free Total Connect Comfort app”.

Remote control is the payoff: “Once connected to Wi-Fi and registered to Total Connect Comfort, you can control your thermostat from anywhere through your laptop, tablet, or smartphone with the Total Connect Comfort app.” Help is listed twice in the guide — “For assistance please visit http://yourhome.honeywell.com , or call toll-free: 1-855-733-5465”.

The Four Buttons

Pages 3 and 4 are quick-reference panels, one for residential and one for commercial use. The four keys are defined identically on both: “HOME. Touch to display Home screen.”, “FAN. Select fan mode.”, “SYSTEM. Select system mode (Heat/Cool).” and “MENU. Touch to display options.”

The rest of the panel labels the touchscreen: “Start here to set a program schedule”, and “Touch an arrow to change temperature setting and select a Temporary or Permanent Hold”.

The Alert Light is “On when alert message is active or system is set to EmHeat.”, and it “Flashes for battery-only power; on continuous if system powered.” Backlighting varies: “It stays lit for 7 seconds after you complete changes.”, yet “Depending on how your thermostat was installed, the screen light may always be on.”

TH8321WF1001 Wi-Fi Setup

Pages 5 to 7 walk through steps 1.1 to 1.8. Touch MENU, then “Select Wi-Fi Setup”, and “The thermostat will scan for available Wi-Fi networks.” The screen shows “Finding Networks Please Wait” “after which it displays a list of all Wi-Fi networks it can find.”

Pick your network: “Find the name of the network you want to use by pressing the arrow buttons to scroll up/down or left/right. Press the Wi-Fi network name, then press Select.” Then “When prompted, press the screen to edit the password (if necessary).” The arrow keys change characters and letter case; “Press Done when complete.”

“The screen will let you know when the connection is successful.” If it fails, “the screen will explain why not”, and the guide adds: “Press the” up arrow “for other tips about this failed connection.”

Two extras sit nearby. Hidden networks: “If the Wi-Fi network name is hidden, see “Connecting to a hidden Wi-Fi network” on page 44.” Signal strength: “You can check signal strength at any time after the thermostat is connected to the Wi-Fi network by pressing MENU then Wi-Fi Setup.”

Later changes are covered too. To move to a new router, MENU then Wi-Fi Setup leads to “Disconnect Wi-Fi Network”; the screen “will show “Wi-Fi Disconnected Successfully.” Touch Done.” Reconnecting repeats the network list, then “The thermostat displays “Connecting Please Wait” then a “Connection Successful” screen.”

Registering With Total Connect Comfort

Wi-Fi alone is not remote access: “If you want remote access to the thermostat, you must set up an account at mytotalconnectcomfort.com and add the thermostat to the account.”

The identifiers are the fiddly part. “You will need the thermostat MAC and CRC IDs to add the thermostat. They are on the screen under Menu, Wi-Fi Setup and on the Thermostat ID Card packed with the thermostat.”

On the site, “After adding your thermostat location, you must enter the thermostat’s unique identifiers”, listed as “MAC ID” and “MAC CRC”. The TH8321WF1001 MAC and CRC IDs “are not case sensitive”, and appear on the Register Online screen or the printed card.

New accounts must be activated: “Check your email for an activation message from My Total Connect Comfort.” If nothing arrives, “check your junk mailbox or use an alternate e-mail address.” Then “the Total Connect Comfort registration screen will display a SUCCESS message.”

One caution about the printed card. The sample card reproduced on page 10 reads “HONEYWELL MODEL: RTH8580WF”, so the artwork in this VisionPRO 8000 user guide PDF shows a sibling model, not the TH8321WF1001. The registration steps are the same; use the card and screen from your own unit.

Clock, Fan and System Mode

Setting the clock is four touches, and registration changes it: “When registered to Total Connect Comfort, the thermostat automatically sets the time and adjusts for Daylight Saving Time.”

Fan modes, from page 13, are defined as: “On: Fan is always on.”, “Auto: Fan runs only when the heating or cooling system is on.”, “Circ: Fan runs randomly about 35% of the time (residential use only).” and “Follow Schedule: Fan controlled by program”.

System modes, from page 14: “Heat: Controls only the heating system.”, “Cool: Controls only the cooling system.”, “Off: Heating/cooling systems are off.”, “Auto: Selects heating or cooling depending on the indoor temperature.” and “Em Heat (heat pumps with aux. heat): Controls auxiliary/emergency heat. Compressor is locked out.” Not everyone sees all five: “The Auto and Em Heat system settings may not appear, depending on how your thermostat was installed.”

Schedules and Holds

Page 15 prints the defaults: “This thermostat uses default Energy Saver settings that can reduce your heating/cooling expenses.” The residential rows are the ones most owners touch.

Preset energy-saving schedules, residential use (page 15)
PeriodStart timeHeatCool
Wake6:00 am70°78°
Leave8:00 am62°85°
Return6:00 pm70°78°
Sleep10:00 pm62°82°

The commercial table below carries a fan column, and about its starred rows the guide states: “Period 2 is cancelled by default. If you activate it, the values shown above are default settings.”

Preset schedules, commercial use (page 15)
PeriodStart timeHeatCoolFan
Occupied 18:00 am70°75°On
Unoccupied 110:00 pm55°85°Auto
Occupied 2*12:00 am70°75°On
Unoccupied 2*12:00 am55°85°Auto

To change any of it, “Select Edit Schedule to display Use Scheduling Assistant?” — “Touch Yes to create a schedule by answering simple questions.” or “Touch No to manually create a program schedule.”

Manual editing runs “Select the days to schedule”, then sets the Wake time and its Heat and Cool temperatures, then “Touch other time periods (Leave, Return, Sleep) to set time and temperatures for each.” “Touch Cancel Period to eliminate any unwanted time period.”, and “Touch Fan Setting to customize fan settings for any time period.”

Holds differ by use. Residential: “The schedule will resume when the Hold Until time expires.”, or “Select Permanent Hold to keep the same temperature until you change it or resume the program schedule.” Commercial: the adjusted temperature “will be maintained for 1 hour and can be adjusted up to the maximum time set by the installer.” Both share “Touch Cancel Hold at any time to resume the program schedule.”

Vacation hold, residential, “helps you save energy while you are away, and restores comfortable settings just before you return home.” Commercial sites get holiday scheduling instead: “Custom Events lets you set up other days for special schedules.”, and “US and Canadian Holiday options let you select from a list of holidays commonly observed in each country.”

Humidity lives under MENU. Dehumidification “can control a dehumidifier or use your air conditioner to reduce humidity”, with a trade-off the guide states plainly: “the temperature may drop up to 3° F below your temperature setting until humidity reaches the desired level.”

For winter, “If frost or condensation appears on the windows, touch MENU, then select Window Protection.”, where you “Use a lower number to prevent frost or condensation.” Two limits apply: “Window Protection is available only if an outdoor air sensor is installed.” and “the thermostat may maintain a 15% separation between humidification and dehumidification settings.”

Ventilation has three modes: “Auto: Ventilation runs as programmed by the installer.”, “Off: Ventilation remains off unless turned on using the timer.” and “On: Ventilation is always on.”, plus Temporary Boost and a Lockout that “prevent ventilation from running during the Sleep or Unoccupied (commercial) program periods or when outdoor conditions exceed values set by the installer.”

Preferences “let you select how the thermostat displays information or responds to certain situations”: filter reminders, Fahrenheit/Celsius, clock format, backlighting, alert light, scheduling, adaptive recovery, default schedule and daylight saving time.

Two housekeeping menus. “When you select the Clean Screen option, the screen is locked so you don’t accidentally change settings while you clean.” — and “Do NOT spray any liquid directly on the thermostat.” Security “can adjust security options to prevent unauthorized changes”: “Unlocked: Full access allowed.”, “Partially locked: Only temperature can be changed.”, “Fully locked: No access allowed.”

Advanced features, page 37, explain the odd behaviour owners report. Recovery: “The thermostat displays “In Recovery” when it turns the system on early.” Installer options “require a password and should only be changed by a qualified technician.”

TH8321WF1001 Troubleshooting

Wi-Fi failures get three named causes on pages 42 and 43, and the guide prints one screen each.

Connection Failed causes (pages 42-43)
ScreenWhat the guide says
Invalid Password“The password you entered is invalid. Check that you have the right password and try again.”
No IP Address“The thermostat was unable to obtain an IP address from the router. Verify the router is correctly set up to automatically assign IP addresses.” If it still fails, “remove the thermostat from the wallplate for 10 seconds, then snap it back into place.”
No Internet Link“The thermostat connected to the Wi-Fi network but was unable to establish a connection to the internet. Check the router settings and try again.”

Page 47 covers the rest under four headings. “Screen is blank”: “Check circuit breaker and reset if necessary.”, “Make sure power switch at heating and cooling system is on.”, “Make sure furnace door is closed securely.”

If the unit runs on cells, “make sure fresh AA alkaline batteries are installed correctly.”

“Screen is difficult to read”: “Change screen brightness using Preferences menu (see page 33).” “Red light is on”: “If thermostat is in Emergency Heat mode, the red light is normal.”, otherwise “an alert is active. Check message on the thermostat screen.”

“Heating or cooling system does not respond”: set SYSTEM to Heat and “Make sure the temperature is set higher than the Inside temperature”, or to Cool and “Make sure the temperature is set lower than the Inside temperature”. Then check breaker, power switch and furnace door.

If the screen says Wait: “If “Wait” is displayed, the compressor protection timer is on. Wait 5 minutes for the system to restart safely, without damaging the compressor.”

Warranty and Fine Print

Page 48 is headed “Up to 5-year limited warranty”, but its own sentence is narrower: “Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer.”

It also warns that “This warranty does not cover removal or reinstallation costs.” Customer Care is the same 1-855-733-5465 number, and the last English page adds “This thermostat contains a Lithium battery which may contain Perchlorate material.”

FAQ

Do I need Total Connect Comfort to use the thermostat?

No. Wi-Fi setup is local. The account is only for remote access, since you “must set up an account at mytotalconnectcomfort.com and add the thermostat to the account.”

Where do I find the MAC and CRC numbers?

Two places, per the guide: “They are on the screen under Menu, Wi-Fi Setup and on the Thermostat ID Card packed with the thermostat.” They are not case sensitive.

Why does my screen say Wait and nothing happens?

Compressor protection. “If “Wait” is displayed, the compressor protection timer is on. Wait 5 minutes for the system to restart safely, without damaging the compressor.”

Why is Circ missing from my fan menu?

The guide defines it as residential-only — “Circ: Fan runs randomly about 35% of the time (residential use only).” In commercial use, “touch Auto or On to temporarily override the programmed fan schedule.”

How long does a commercial hold last?

“The new temperature will be maintained for 1 hour and can be adjusted up to the maximum time set by the installer.”

Honeywell RM7895A1014 Installation Manual

Honeywell RM7895A1014 Installation Manual

This Honeywell RM7895A1014 Installation Manual guide follows the 28-page document honeywellmanual.com lists under that name: form 65-0205, marked “PRODUCT DATA”, “Copyright © 1996 Honeywell Inc.” and titled “7800 SERIES EC7895A, RM7895A RELAY MODULE”. Installation begins on page 9; troubleshooting starts on page 26.

One naming point first. The body text never prints RM7895A1014. It says RM7895A, while the only “1014” in the document belongs to the Q7700A1014 network interface unit. Treat the listing title as the catalog name and look for RM7895A on the label.

The manual calls the product “a microprocessor based integrated burner control for automatically fired gas, oil, or combination fuel single burner applications”, and assembles it from four parts: “The RM7895 consists of the Relay Module. Subbase, Amplifier and Purge Card.”

Download Honeywell RM7895A1014 Installation Manual (PDF)

Table of Contents

What the Manual Covers

The contents page runs General, Features, Specifications, Ordering Information, Principal Technical Features, Safety Provisions, Installation (page 9), Wiring (11), Assembly (14), Operation (17), Checkout (20) and Troubleshooting (26). The EC7895A shares every chapter; it is the 200 Vac version and carries its own terminal table, Table 1B.

The feature list opens with safety: airflow switch check, closed loop logic test, dynamic AMPLI-CHECK, dynamic input check, dynamic safety relay test, dynamic self-check logic, internal hardware status monitoring, and tamper resistant timing and logic. Five LEDs report the sequence: “POWER, PILOT, FLAME, MAIN and ALARM.” Nonvolatile memory retains “history files and sequencing status after loss of power.”

The optional Keyboard Display Module adds a “2 row by 20 column Vacuum Fluorescent Display (VFD)” for first-out annunciation. The system “distinguishes 43 modes of failure and detects and annunciates difficult-to-find intermittent failures.”

Electrical and Environmental Ratings

The RM7895A supply is “100 Vac (+10/-15%), 50 or 60 Hz (+/- 10%).” Power dissipation is “10W maximum”, the load ceiling is “2000 VA maximum connected load to 7895 Assembly.”, and fusing is “20A maximum, type FRN or equivalent”. The EC7895A takes 200 Vac; Table 1B covers its terminals.

The environmental block gives operating −40 °F to 140 °F and storage −60 °F to 150 °F, plus “85% RH continuous, noncondensing” and a “0.5G environment.” With its dust cover the module weighs “1 pound 15 ounces, unpacked.”

Approvals are split by model: “RM7895A: Underwriters Laboratories Inc. listed: File no. MP268, Guide no. MCCZ. Factory Mutual approved.” The EC7895A entry lists Factory Mutual only. Dimensions sit in Fig. 1 and Fig. 2 rather than in the text.

RM7895A Terminal Ratings

Table 1A is headed “RM7895A Terminal Ratings.” It runs from the two ground entries through terminal 22; terminals 12 to 21 print “Unused” on every row and are omitted here, with the warning repeated below.

Table 1A: RM7895A terminal ratings (page 2)
TerminalDescriptionRating
G“Flame Sensor Ground Earth”—
G“Earth Ground”—
2“L2(N)”, “Line Voltage Common”—
3Alarm“100 Vac, 1A pilot duty.”
4Burner Motor“100 Vac, 9.8 AFL, 58.8 ALR (inrush).”
5Line Voltage Supply (L1)“100 Vac (+10/-15%), 50 or 60 Hz (+/- 10%).”
6Burner Controller and Limits“100 Vac, 1 mA.”
7Airflow Interlock“100 Vac, 9A.”
8Pilot Valve/Ignition“100 Vac, 4.5A ignition and 50VA pilot duty.”
9Main Fuel Valve“100 Vac, 2A pilot duty.”
10Ignition“100 Vac, 4.5A ignition.”
F(11)Flame Sensor“60 to 220 Vac, current limited.”
22Shutter“100 Vac, 0.5A”

Terminals 12 to 21 are “Unused”, and the wiring figures warn “DO NOT CONNECT ANY WIRES TO UNUSED TERMINALS.”

What a Complete Installation Needs

Three items are required besides the RM7895A relay module: “Plug-in Flame Signal Amplifier, see Table 2. Plug-in Purge Timer Cards: Selectable ST7800A, two seconds to 30 minutes. Q7800A or Q7800B.”

Table 2 sorts amplifiers by detection method and colour: rectification (green) R7847A, AMPLI-CHECK R7847B and self-check R7847C; infrared (red) R7848A and R7848B; ultraviolet (purple) R7849A and R7849B, plus the self-checking R7861A and R7886A. “Make sure the correct combination of amplifier and flame detector(s) is used.”

One footnote matters on continuously firing equipment: “The C7012A,C, C7027, C7035 and C7044 Flame Detectors should be used only on burners that cycle on-off at least once every twenty-four hours.” The subbase choice is “Q7800A for panel mount or Q7800B for wall or burner mount”, and “PURGE is determined by the ST7800A Purge Card selected.”

Mounting the Q7800A Subbase

Mount the subbase in any position except horizontally with the bifurcated contacts pointing down. The standard vertical position is recommended; any other position decreases the maximum ambient temperature rating.

Choose a wall, burner or panel location; the Q7800 can sit in the control cabinet. Leave service clearance for the module, cover, amplifier and probes, then use the back of the subbase as a template for four no. 6 screws.

Mount the module vertically, or horizontally with the knife blade terminals pointing downward. On a Q7800A it must be inside an electrical enclosure. Tuck wiring against the back of the subbase, align the four L-shaped corner guides, and use “a plug-in motion rather than a hinge action.”

Site limits are strict: “The EC7895 or RM7895 is not designed to be weather tight.” Outdoors it needs an approved weather-tight enclosure. Condensing moisture can cause a safety shutdown, and vibration must not exceed 0.5G continuous.

Wiring Rules and Limits

Start with the disconnect: “Disconnect the power supply before beginning installation to prevent electrical shock and equipment damage.” More than one power disconnect may be involved. Use “no. 14, 16, or 18 copper conductor (TTW60C or THW75C or THHN90C) 600 volt insulation wire for all Line Voltage terminals.”

Grounding gets its own paragraph: the earth wire must be able to blow the 20A fuse in an internal short, the path must be low impedance, and wide straps or brackets are preferred over leadwires.

For flame detector wiring, “Do not run high voltage ignition transformer wires in the same conduit with the flame detection wiring.” Keep sensor leads short, because “The maximum permissible leadwire length depends on the type of flame detector, leadwire and conduit.” Control and airflow interlock leads top out at 300 feet.

One discrepancy deserves a meter. Fig. 7 labels the supply “120V, 50/60 Hz POWER SUPPLY.” while page 2 rates the module at “100 Vac (+10/-15%)”, which tops out at 110 Vac. Check the panel against Table 1A first.

Complete the static checkout with the module off the subbase: “After checking all wiring, perform this checkout before installing the EC7895 or RM7895 on the subbase.”

Purge Card, Cover and Amplifier

The ST7800A purge card goes in after the dust cover or display module comes off. Pull upward on the plastic support cover to release the old card, confirm the replacement has the desired timing, insert it into the opening, refit the cover, restore power, and run at least one complete cycle.

For the amplifier, disconnect power, align the circuit board edge connector with the keyed receptacle, “Ensure the amplifier nameplate faces away from the Relay Module”, push until fully inserted, then seat it toward the retaining clasp. The dust cover aligns by its two interlocking ears and slots. “Perform all required checkout tests.”

Flame detector installation defers to the detector instructions, with one rule repeated here: “Keep the flame signal leadwires as short as possible from the flame detector to the wiring subbase.”

Sequence, Jumpers and the LEDs

Power-up starts a ten-second INITIATE period. If line voltage or frequency falls outside +10/−15% or ±10%, the module holds, and “If the condition is not corrected and the hold condition exists for four minutes, the RM7895 locks out.”

STANDBY waits for a call for heat and the correct state on the burner switch, limits and monitored circuits. PREPURGE is selectable from two seconds to 30 minutes, with the blower motor output on terminal 4. The airflow interlock must close ten seconds into PREPURGE or within the purge card timing.

During the pilot trial, terminals 8 and 10 energize. Flame must prove within the 4 or 10 second PFEP; then ignition drops out and terminal 9 powers the main fuel valve. A flameout brings lockout or recycle “within .8 or 3 seconds, depending on the Flame Failure Response Time (FFRT) of the amplifier.”

Sequence timing for normal operation (page 5)
DeviceInitiateStandbyPurgePilotMain
EC7895A/RM7895A10 sec.***4 or 10 sec.No

* STANDBY and RUN can be infinite. ** PURGE is set by the ST7800A card. The main column prints “No”.

Three site-configurable jumpers set the behaviour; clip them with side cutters and remove the resistors, which the manual says enhances safety.

Table 3: site-configurable jumper options (page 19)
JumperFunctionIntactClipped
JR1Pilot Flame Establishing Period10 seconds4 seconds
JR2Flame Failure ActionRecycleLockout
JR3Airflow Switch (ILK) FailureRecycleLockout

The green POWER LED blinks every four seconds while the hardware runs correctly; PILOT, FLAME, MAIN and ALARM report the rest.

Checkout and Flame Signal

Table 4 holds seven static tests. They jumper the subbase and read voltage to L2: 5-L2 for line voltage, 6-L2 for limits, 4-5 to start the burner motor and see 7-L2 within ten seconds, 5-10 for ignition, 5-8 for pilot, 5-9 for the main valve, and 5-3 for the alarm. Close all manual fuel shutoff valves first.

Do not megger the installed control: “Do not perform a dielectric test with the EC7895 or RM7895 installed.”

The flame signal floor is 1.25 Vdc, with 5.0 Vdc expected at the Keyboard Display Module or at a 1M ohm/volt meter. “Measure the flame signal at the appropriate times defined in the following checkout tests.” Read at the + and − (Com) jacks on the 0 to 10 Vdc range.

Five safety shutdown tests close the section: an airflow interlock closed during PREPURGE, PILOT IGN, MAIN IGN or RUN; a simulated flame 40 seconds after STANDBY entry or 30 seconds into PREPURGE; failed pilot ignition; failed main ignition; and loss of flame during RUN. “Safety shutdown occurs.” each time.

On replacement: “If an EC7895 or RM7895 is replaced with a lower or higher functioning 7800 SERIES Relay Module, the burner will not sequence unless wiring changes are made.”

RM7895A Troubleshooting

RM7895A troubleshooting starts at the ALARM LED and, if fitted, the Keyboard Display Module. “First-out Annunciation reports the cause of a safety shutdown or identifies the cause of a failure to start or continue the burner control sequence with text and numbered code via the optional Keyboard Display Module.” Self-diagnostics separate field faults from internal ones.

Nonvolatile memory keeps “Historical Information for the six most recent lockouts”, with the cycle, hour, fault message and burner status at the time of each fault. Status messages are STANDBY, PRE-PURGE, PILOT IGN, MAIN IGN and RUN.

Display holds are STANDBY HOLD F/G (flame detected), STANDBY HOLD T7 (closed airflow interlock), PURGE HOLD F/G and PURGE HOLD T7. A flame that does not clear within 40 seconds in STANDBY locks the RM7895 out; either purge hold locks out after 30 seconds.

Reset with the pushbutton, or remotely through a Keyboard Display Module, DATA CONTROLBUS MODULE, Extension Cable Assembly or Remote Reset Module. “A power-up reset causes an electrical reset of the EC7895 or RM7895 but does not reset a lockout condition.” For deeper diagnostics the manual points to “the 7800 SERIES System Annunciation Diagnostics and Troubleshooting, form 65-0118.”

FAQ

Does the manual print the model number RM7895A1014?

No. The body prints RM7895A; the only “1014” is inside the Q7700A1014 part number on page 5. The listing title carries the longer number.

What supply voltage does the RM7895A require?

“100 Vac (+10/-15%), 50 or 60 Hz (+/- 10%).” Fig. 7 labels its supply “120V, 50/60 Hz POWER SUPPLY.” which sits outside that band, so verify the panel voltage before wiring.

Which subbase and purge card fit the RM7895A?

“Q7800A for panel mount or Q7800B for wall or burner mount.” The purge card is a “Selectable ST7800A, two seconds to 30 minutes”, and its timing sets the PREPURGE period.

How long are INITIATE, PREPURGE and the pilot trial?

INITIATE lasts ten seconds if the supply stays within tolerance. PREPURGE runs from two seconds to 30 minutes, set by the ST7800A card. The pilot flame establishing period is 10 seconds with JR1 intact and 4 seconds with JR1 clipped.

What flame signal is acceptable?

At least 1.25 Vdc, and 5.0 Vdc expected at the Keyboard Display Module or a 1M ohm/volt meter. Measure at the amplifier’s + and − (Com) jacks on the 0 to 10 Vdc range.

How do I clear a lockout?

Press the reset pushbutton, or use a remote reset if one is wired. A power-up reset does not clear a lockout. The module retains the six most recent lockouts, with cycle, hour, fault message and burner status.

Honeywell Aquastat L4006A Installation Instructions

These boiler-mounted, immersion type controllers operate in response to temperature changes in hydronic heating systems. The L4006 family covers high limit, low limit and circulator duty on hydronic boilers, in immersion well and surface mount versions. This page reproduces form 60-0915—06 in full, including the heat-conductive compound material safety data sheet that ships with the immersion well models.

Internal view of the L4006A,B Aquastat controller with the case open, showing the setpoint indicating dial, differential adjustment wheel, adapter clamp screws and horizontal immersion well
Fig. 1. Internal view of L4006A,B with horizontal well. L4006E is the same with reset button added.

Application

Model Switch action How it is used
L4006A Breaks the circuit on a temperature rise to the control setting. High limit or low limit control. When used as a controller or as a low limit, a separate high limit must be used.
L4006B Makes the circuit on a temperature rise. Circulator controller, delaying circulator operation when boiler water temperature is below the control setting.
L4006E Breaks the control circuit when the controlled medium reaches the high limit setting; trip-free manual reset. A reset button on the front of the case must be pressed to re-establish the control circuit.
L4006H Breaks the control circuit at the high limit setting; trip-free manual reset, as on the L4006E. Includes bracket and clamp for surface mounting on pipe or tank.

A plastic bag of heat-conductive compound is included with the L4006A,B,E Aquastat® Controllers for use when the sensing bulb is inserted into a well designed for a large bulb than the one used on the L4006A,B,E. A 124904 Well Adapter, for use on old wells that do not fit the L4006A,B,E immersion well clamp, can be ordered; see form 68-0040, Wells and Fittings for Temperature Controllers. A setting stop is included to prevent setting above a desired temperature on limit.

If a well adapter or other accessories are needed, refer to form 68-0040, Wells and Fittings for Temperature Controllers, for part numbers and ordering information.

Installation

WARNING — Electrical shock hazard. Can cause serious injury, death or equipment damage. Disconnect the power supply before beginning installation to prevent electrical shock or equipment damage.

When installing this product…

  1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
  2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.
  3. Installer must be a trained, experienced service technician.
  4. After installation is complete, check out product operation as provided in these instructions.

Installing immersion well models (L4006A,B,E)

Important: Obtain the best thermal response with a well that snugly fits the sensing bulb. The bulb should be inserted until it rests against the bottom of the well. Use a well of correct length and bend the tubing, if necessary, to provide enough force to hold the bulb against the bottom of the well. Do not make a sharp bend in the tubing. A sharp bend can produce a break in the tubing and cause a loss of fill. This condition will cause the high and low limit controls to be made continuously.

If the well is not a snug fit on the bulb, use the heat-conductive compound as follows. Fold the plastic bag of compound lengthwise and twist gently. Snip the end of the bag and insert into the well. Slowly pull out the bag while squeezing firmly to distribute the compound evenly in the well. Insert the bulb into the well. Bend the tubing, if necessary, to provide force to hold the bulb against the bottom of the well and to hold the out end of the bulb in firm contact with the side of the well. Wipe off any excess compound.

Note: Some models have an adjustable capillary tubing length to 3 inches (76 mm). In these models, pull out extra tubing from inside the case, if needed.

Follow the boiler manufacturer instructions, if available; otherwise, proceed as follows.

  1. Remove the old control.
  2. Refer to the cover insert of the old control to identify and tag each lead as it is disconnected.
  3. Leave the old well in place if it is suitable.

If the well is otherwise suitable but does not fit the L4006 immersion well clamp

Use a 124904 Well Adapter (order separately, see form 68-0040) to secure the L4006 to the old well. The adapter has a flange at one end for fastening the L4066 adapter clamp.

  1. Loosen, but do not remove, the two adapter clamp screws (see Fig. 1).
  2. Slide the adapter onto the capillary and short tube; see Fig. 2 inset.
  3. Make sure the flanged end of the adapter fits into the hole in the case. Position the adapter well clamp snugly over the flange on the adapter, then tighten the clamp screws.
  4. Insert the bulb into the well, as shown in Fig. 2. If necessary, use the heat-conductive compound as instructed in the IMPORTANT statement above.
  5. Tighten the setscrew (if one is present in the old well spud) against the adapter.

If the old well is unsuitable

  1. Drain the system and remove the well.
  2. Select a new well from form 68-0040 (order well separately).
  3. Install the new well, refill the system and check for leaks.
  4. Loosen, but do not remove, the two adapter clamp screws (Fig. 1).
  5. Insert the sensing bulb into the well until it bottoms as show in Fig. 2. Add heat-conductive compound, if necessary, as instructed in the IMPORTANT statement above.
  6. Make sure the end of the well fits into the hole in the case. Position the immersion well clamp snugly over the well flange and tighten the clamp screw securely.
Sectional drawing of the sensing bulb inside an immersion well, showing the well adapter, adapter clamp, capillary tube, setscrew and heat-conductive compound, with an inset of the back of the case
Fig. 2. Bulb in immersion well and use of adapter.
Diagram notes (text version)
  • Slightly bend in tubes should hold bulb in good thermal contact with the well at two opposite points, as in (A) and (B).
  • Assure that tubes fit freely in adapter so that tension of the capillary tube at point (C) holds the sensing bulb in good thermal contact with the bottom of well at point (D).

Surface mounting the L4006H

The L4006H is designed for surface mounting on piping or tank and can be mounted in any position.

When mounting the L4006H on piping, the pipe should be 1 in. (25 mm) diameter or larger for accurate temperature sensing.

  1. Remove any insulation from the pipe.
  2. Thoroughly scrape off all scale, rust or paint.
  3. Mount controller as shown in Fig. 3 using adjustable 12 in. (294 mm) pipe strap furnished.

When mounting the L4006H on a tank, use a pipe strap of appropriate length, approximately 6-10 ft (17.6- 29.4m) for the tank (not provided). Fit the pipe strap through the slot in the mounting bracket. See Fig. 3.

L4006H controller case fastened to a vertical pipe with the 12 inch adjustable pipe strap and mounting bracket
Fig. 3. Mount L4006H directly on surface.

Wiring

WARNING — Electrical shock hazard. Can cause serious injury, death or equipment damage. Disconnect power supply before connecting wiring to avoid electrical shock or equipment damage.

All wiring must comply with local codes and ordinances regarding wire size, insulation, enclosure, etc. See Fig. 4 and 5 for typical diagrams of Aquastat® Controllers used in heating systems.

Use these Aquastat Controllers with copper wire only.

Typical hookup diagram for a gas-fired system with domestic hot water: 24 volt thermostat, low water cutoff, pressure control, L4006A or L4007A low limit Aquastat controller, gas valve and Pilotstat control
Fig. 4. Typical hookup for gas-fired system with domestic hot water.
Diagram notes (text version)
  • Power supply. Provide disconnect means and overload projection as required.
  • Use L4006E for manual reset.
Hookup diagram for an oil-fired summer-winter hydronic system with domestic hot water: RA832A switching relay, high limit and low limit Aquastat controllers, circulator Aquastat controller, ignition, circulator, burner and Protectorelay control
Fig. 5. Hookup for oil-fired, summer-winter, hydronic system with domestic hot water. This is typical where control for domestic hot water is added, or where each Aquastat Controller is mounted in a separate location.
Diagram notes (text version)
  • Power supply. Provide disconnect means and overload protection as required.
  • Use L4006E for manual reset.

Operation

For proper selections of settings, follow boiler manufacturer recommendations:

  1. High limit controller: Shuts off burner when water temperature exceeds high limit setting. Burner restarts when temperature drops to high limit setting minus the temperature differential.

Note: If L4006E or H, see Manual Reset section.

  1. Low limit controller: Maintains minimum boiler temperature for domestic hot water. Turns boiler on at temperature setting, less differential.
  2. Circulator controller: Prevents circulation of water that is not hot enough. Breaks circulator circuit at temperature setting minus differential and remakes at setting.

Adjustment

Set the differential to correspond with the boiler manufacturer recommendations. To adjust models with adjustable differential, rotate the wheel on the back of the snap switch until the desired reading is aligned with the V notch in the frame. The wheel provides an adjustment from 5°F to 30°F (3°C to 17°C). Replace the cover on the Aquastat Controller.

Adjust the control point to correspond with the boiler manufacturer recommendations. To adjust, insert a screwdriver in the slotted screw type head located beneath the window in the cover. Turn the scale to the desired control point.

Manual reset

When the device includes manual reset (L4006E and H), be sure to press the red reset button on the front of the case to make sure that the controller is not locked out on safety. When checking out the system, adjust the control point low enough so the temperature of the controlled medium reaches the high limit setting, the burner shuts off, and the Aquastat Controller locks out. When the temperature of the controlled medium drops to the high limit setting minus differential, push the manual reset button and the system should be operative again. Reset control to proper high limit setting.

Checkout

Check to make certain that the Aquastat Controller has been installed and adjusted properly. Put the system into operation and observe the action of the device through several cycles to make certain that it provides proper control of the system as described in the Operations section. Further adjustments can be made to meet more exact comfort requirements.

Heat-conductive compound: material safety data sheet (DS9021)

Section 1. Product and company identification

  • Product name: Heat Conductive Compound
  • MSDS ID: DS9021
  • Synonyms: MS1699
  • Product use: Heat conductive material used to enhance contact and heat transfer in temperature sensor applications.
  • Manufacturer: Resideo Technologies Inc., 1985 Douglas Drive North, Minneapolis, MN 55422.
  • Date released: October 8, 1999
  • Customer Response Center: 800-328-5111
  • Emergency telephone information: 888-809-3787
  • NFPA ratings: Health 0; Flammability 1; Reactivity 0; Personal Protection B

Section 2. Composition, information on ingredients

Ingredient CAS number Percent PEL TVL
#2 Lithium Complex Grease (70%):
Mineral Oil 64742-65-0 35-50 5 mg/m3 5 mg/m3
Mineral Oil 64742-62-7 20-25 5 mg/m3 5 mg/m3
Lithium Hydrostearate/Sebacate Complex 68815-49-6 4-9 — —
Zinc Alkyldithiophosphate 68649-42-3 0-2 — —
Aluminum Paste (30%):
Aluminum, as Al 7429-90-5 20-25 15 mg/m3 10 mg/m3
Aliphatic Petroleum Distillates 8052-41-3 10-15 2900 mg/m3 525 mg/m3
Stearic Acid 57-11-4 1-2 — —
Aromatic Petroleum Distillates 64742-95-6 1-2 5 mg/m3 5 mg/m3

Additional information: Part No. 120650 (0.5 oz tube); Part No. 107408 (4 oz can); Part No. 197007 (5 gallon container). May also contain minute amounts of lithium and molybdenum lubricant compounds.

Section 3. Hazard identification

Acute health effects

  • Skin: Excessive contact may cause skin irritation and dermatitis.
  • Eye: Direct contact with eye will cause irritation.
  • Inhalation: No adverse effects are expected.
  • Ingestion: Ingestion of product may cause nausea, vomiting and diarrhea.

Chronic health effects

  • Existing skin rash or dermatitis may be aggravated by repeated contact.
  • OSHA hazard classifications: None.
  • Carcinogenicity: Not considered to be a carcinogen by either OSHA, NTP, IARC, or ACGIH.

Section 4. First aid measures

  • Eye contact: Flush eyes with water for 15 minutes. Remove any contact lenses and continue to flush. Obtain medical attention if irritation develops and persists.
  • Skin contact: Remove excess with cloth or paper. Wash thoroughly with mild soap and water. Obtain medical attention if irritation develops and persists.
  • Ingestion: Contact physician or local poison control center immediately.
  • Inhalation: Remove patient to fresh air and obtain medical attention if symptoms develop.

Section 5. Fire fighting measures

  • Material flash point: > 383°F (195°C). Will burn if exposed to flame.
  • Extinguishing media: Carbon dioxide, dry chemical or foam.
  • Special fire fighting procedures: None.
  • Explosion hazards: None. Aluminum powder can react with water to release flammable hydrogen gas. In the form of this product, this reaction is not expected.

Section 6. Accidental release measures

Scrape up and dispose of as solid waste in accordance with state and federal regulations.

Section 7. Handling and storage

Store in dry place. Keep container closed when not in use.

Section 8. Exposure controls and personal protection

  • Ventilation: No special ventilation is required when working with this product.
  • Respiratory protection: None required.
  • Eye protection: Not normally required. However, use chemical safety goggles or faceshield if potential for eye contact exists, especially if material is heated.
  • Hand/clothing protection: Not normally required. Protective gloves and clothing are recommended, as material is difficult to remove from skin and clothing.
  • Other protective equipment: None required.

Section 9. Physical and chemical properties

  • Appearance/odor: Aluminum color, semi-solid material, pleasant odor.
  • Solubility in water: Negligible.
  • Specific gravity: 0.86.

Section 10. Stability and reactivity

  • Stability: Stable.
  • Reactivity: Hazardous polymerization will not occur.
  • Incompatibilities: Strong oxidizing agents and halogens.
  • Hazardous decomposition products: Carbon dioxide, carbon monoxide.

Section 11. Toxicology information

No data available.

Section 12. Ecological information

Chemical fate information: Hydrocarbon components will biodegrade in soil; relatively persistent in water.

Section 13. Disposal consideration

Dispose of as solid waste in accordance with local, state and federal regulations.

Section 14. Transportation information

DOT classification: Not classified as hazardous.

Section 15. Regulatory information

SARA Title III supplier notification: Include in Section 311/312 inventory reports if amounts exceed 10,000 pounds. Aluminum compounds are subject to the reporting requirements under Section 313 of Emergency Planning and Community Right-To-Know Act of 1986 (40 CFR 372). Ingredients listed in TSCA Inventory.

Section 16. Other information

This information is furnished without warranty, expressed or implied, except that is is accurate to the best of our knowledge.

Document information

Resideo Technologies, Inc., 1985 Douglas Drive North, Golden Valley, MN 55422. Customer care: 1-800-468-1502. www.resideo.com. © 2020 Resideo Technologies, Inc. All rights reserved. This product is manufactured by Resideo Technologies, Inc. and its affiliates.

60-0915—06   M.S. Rev. 05-20  |  Printed in United States

Download:Honeywell L4006,7,8; L6006,7,8 AquastatÆ Controllers Manual.pdf

Honeywell CT410B Thermostats Installation Instructions

above.

Resideo T410 line voltage electric heat thermostat with temperature setting knob
T410 electric heat thermostat.

Specifications

  • Models: T410A provides single-line break. T410B provides double-line break.
  • Temperature range: 40°F to 80°F (4°C to 27°C)
  • Electrical ratings: 60 Hz noninductive; 22A at 120-240 Vac; 19A at 277 Vac

Safety notices

WARNING — Electric shock hazard. This thermostat is a line voltage control (120 Volts to 277 Volts.) Do not install it if you are not completely familiar with house wiring. If handled improperly, there can be risk of a 120 Volt to 277 Volt electric shock hazard, which may cause serious injury or death.

Mercury notice. If this control is replacing a control that contains mercury in a sealed tube, do not place you old control in the trash. Dispose of properly.

Contact you local waste management authority for instruction regarding recycling and the proper disposal of a old control.

1. Preparation

  1. Proper installation of your Resideo thermostat will occur if you follow these instructions STEP-BY-STEP. It is recommended that as you read, understand and complete each step, you check it off with pencil or pen.
  2. Check thermostat suitability for your home system by reviewing the ratings listed on this page.
  3. Make certain that your heating system is working, especially if it has been inoperative for a length of time. If the system does not work, contact your local electrician for assistance.
  4. Carefully unpack your new thermostat. To avoid damage to the sensing element, do NOT remove the thermostat cover until wiring has been completed.
  5. Save packages of screws, instructions, receipt and proof-of-purchase.

2. Remove Old Thermostat

WARNING — Electric shock hazard. Begin by turning off power to the heating circuit at the main service panel.

  1. Remove cover of old thermostat. Cover normally snaps off when pulled firmly from the bottom. If it resists, check for a screw that locks the cover.
  2. Loosen screws holding thermostat base to outlet box and lift away.
  3. Disconnect wires from old thermostat. As you disconnect each wire, tape the end and label it with the letter of the terminal designation to make reconnection to new thermostat easier.
  4. Check the old insulation for cracks, nicks or fraying, and apply high quality plastic tape where necessary for adequate insulation.
  5. Retain the old thermostat for reference purposes and until your new thermostat is functioning smoothly.

3. Wire and Mount New Thermostat

  1. Connect wires to the thermostat as shown in the applicable wiring diagram.
  2. Remove thermostat cover by grasping the top and bottom ends with fingers, and pulling outward.
  3. Push the wires into the outlet box, and insert the thermostat into the box for mounting by pushing against top and bottom of the thermostat base.

Important: Do not press on setting knob.

  1. Secure the thermostat to the box with the two captive mounting screws provided.
  2. Replace thermostat cover.
  3. Set knob to desired room temperature.

Important: Rough handling or strong pressure can damage knob or sensing element, and change calibration.

Wiring diagrams for T410B double-line break and T410A single-line break thermostats, with legend notes and caution about aluminum conductors
Fig. 1. T410B (double-line break, left) and T410A (single-line break, right) wiring diagrams.
Diagram notes (text version)
  • Power supply. Provide disconnect means and overload protection as required.
  • Breaks on positive off.
  • Exposed unused leadwires to be properly insulated.
  • Thermally activated—breaks on temperature rise. Makes on temperature fall.

Caution: Special service CO/ALR solderless connectors must be used when connecting with aluminum conductors; otherwise, a fire hazard can result.

4. Check Out Thermostat

  1. Turn on the power to the heating system.
  2. Turn setting knob all the way clockwise; listen for clicking sound as switch makes contact. Electric heater should begin operation.
  3. Turn knob all the way counterclockwise; listen for clicking sound as switch breaks contact. Electric heater should shut off.

5. Setting Thermostat

  1. Begin with knob to the desired setting (typically 70°F [20°C] on the scale).
  2. If this setting is not satisfactory after at least two hours of operation, turn setting knob upscale to raise the temperature, or downscale to lower the temperature. Move knob only a degree each time.

6. Troubleshooting

Your Resideo thermostat requires little or no attention. Most problems can generally be traced to the following:

Table 1. Troubleshooting.

Symptom Checkout Action
No heat. Make sure power is on at main service panel. Turn the temperature setting knob fully clockwise. Heater should start to warm up within two minutes. If not, contact qualified electrician to check thermostat and heater.
Improper connections to thermostat. With power to circuit OFF, tighten all wiring connections. Repair any frayed or broken wires.
Other. Contact a qualified electrician for assistance.
Heater never turns off. Turn temperature setting knob fully counterclockwise. Heater should start to cool within minutes. If not, turn off power at the main service panel, and contact qualified electrician.
Thermostat setting and thermometer reading disagree. Thermostat affected by drafts or radiant heat. Contact electrician to change the location. The thermostat should be about 5 ft (1.5m) above the floor and on an inside wall.

1-Year Limited Warranty

Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one (1) years from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option).

If the product is defective,

  1. return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or
  2. call Resideo Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage which occurred while the product was in the possession of a consumer.

Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.

Document information

This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502. ©2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved. www.resideo.com

Resideo Inc., 1985 Douglas Drive North, Golden Valley, MN 55422

69-1562—02   M.S. Rev. 07-19  |  Printed in United States

Honeywell RTH7500D Programmable Thermostat Owner’s Manual

The Honeywell RTH7500D Programmable Thermostat Owner’s Manual is a 64-page booklet, document 69-1730, dated 2004. It carries the installation steps on pages 3 to 38 and the operating instructions on pages 39 to 61, then customer assistance and the warranty. This page works through the operating half in the order an owner meets it. It starts with the display and the buttons, then the schedule, the holds, the maintenance reminders and the fourteen fault entries the booklet prints. Wiring and the installer setup numbers are kept as reference tables further down.

Download the Honeywell RTH7500D Owner’s Manual (PDF)

Skip to PDF content

Honeywell TH8110U1003 VisionPro Thermostat Operating Manual

Honeywell TH8110U1003 VisionPro Thermostat Operating Manual

This Honeywell TH8110U1003 VisionPro Thermostat Operating Manual guide is for the touchscreen that arrived pre-programmed and only needs a clock set. Everything below is quoted from the 32-page PDF, with the page number attached so you can check it.

Table of Contents

What Is the TH8110U1003?

Plain answer: a touchscreen thermostat for a single-stage system, sold as part of the VisionPro TH8000 Series. The manual calls it “the world’s most advanced, easy-to-use thermostat” (page 2).

One booklet covers three models, and the differences matter. Page 1 prints the list, “This manual covers the following models”:

  • “TH8110U: For 1 Heat/1 Cool systems”
  • “TH8320U: For up to 3 Heat/2 Cool systems”
  • “TH8321U: For up to 3 Heat/2 Cool systems with dehumidification”

The model number decides what the extra menu options do; to find it, “Pull thermostat from wallplate and turn over to find model number” (page 1).

Page 1 also warns: “Never use sharp instruments, such as a pencil or pen, to press touchscreen keys.”

Controls at a Glance

Page 4 prints the screen with every key labelled, and the captions under it say what each key does:

Touchscreen keys, from the quick reference on page 4
KeyWhat the manual says it does
SCHED“Press to set program schedule (see page 11)”
HOLD“Press to override program schedule (see pages 12-14)”
CLOCK“Press to set clock (see page 6)”
SCREEN“Press to lock keypad for 30 seconds to clean screen (see page 17)”
MORE“Press for more options (select models only)”
FAN“Press to select fan operation (see page 7)”
SYSTEM“Press to select system type (see page 8)”

Page 5 lists the status line: “Cool On: Cooling system is activated”, “Heat On: Heating system is activated” and “Recovery” — for when “Adaptive Intelligent Recovery in effect (see page 15)”, the feature that lets the thermostat “learn” how long the furnace and air conditioner take “to reach programmed temperature settings”. Heat running early for a wake-up isn’t a bug.

Clock, Fan and System Settings

Set the clock first. Page 6: “To set the current time display, press CLOCK, then press” the up or down arrow, and DONE saves. The note that separates it from a cheap dial: “The real-time clock should never require adjustment since it automatically updates for daylight savings time, and stores all date/time information”. The weekday is set in the advanced functions.

Fan has three modes, and page 7 defines them exactly:

  • “On: Fan is always on.”
  • “Auto: Fan runs only when the heating or cooling system is on.”
  • “Circ: Fan runs randomly, about 35% of the time, not counting any run time with the heating or cooling system.”

Two fine points from that page: “If a fan schedule is programmed, “Auto” will run the fan schedule”, and a forced fan stays put — “the setting you select will remain active until you press FAN again to select Auto”.

Page 8 gives SYSTEM its positions: “Heat: Thermostat controls only the heating system.” “Cool: Thermostat controls only the cooling system.” “Off: Heating and cooling systems are off.” “Auto: Thermostat automatically selects heating or cooling depending on the indoor temperature.” A fifth, Em Heat, is flagged “Select models only”, and its result is blunt: “Compressor is locked out.”

Programming the Schedule

The Honeywell VisionPro thermostat programming instructions begin on page 9, under “Save money by setting program schedules”, which defines the four periods by what you’re doing in them:

  • Wake — “Set to the time you awaken and the temperature you want during the morning, until you leave for the day.”
  • Leave — “Set to the time you leave home and the temperature you want while you are away (usually an energy-saving level).”
  • Return — “Set to the time you return home and the temperature you want during the evening, until bedtime.”
  • Sleep — “Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level).”

The factory schedule assumes a conventional day. Page 3 states the presets in one line: “energy-saving levels while you’re at work or asleep (assumes you wake at 6 am, leave at 8 am, return at 6 pm and go to bed at 10 pm)”.

Adjusting a period

Page 11’s steps, in the manual’s own words:

  1. “Press SCHED, then EDIT.”
  2. “Press day buttons (MON-SUN) to select day(s).”
  3. Set that period’s time and its heat and cool temperatures with the up or down arrow.
  4. “Press other time periods (LEAVE, RETURN, SLEEP) to set time and temperatures for each.”
  5. Press DONE to save, or CANCEL to leave without saving changes.

Two helpers: “You can press CANCEL PERIOD to eliminate any unwanted time period”, and “Press FAN to customize fan settings for any time period (see page 7)”. The day buttons copy one day onto others — the screen prints “OK TO PICK MULTIPLE DAYS” above them. Want two periods instead of four? Advanced function 0540 switches between “Two program periods (Wake, Sleep)” and “Four program periods (Wake, Leave, Return, Sleep)” (page 25).

Temporary, Permanent and Vacation Holds

Temporary. Press the up or down arrow: “This will temporarily override the temperature setting for the current time period.” When the timer expires or you press CANCEL or SCHED, “the program schedule will resume and set the temperature to the level you’ve programmed”.

Permanent. “Press HOLD to permanently adjust the temperature. This will turn off the program schedule.” Page 13: what you set “will be maintained 24 hours a day until you manually change it or press CANCEL (or SCHED) to cancel “Hold” and resume the program schedule.”

Vacation. Page 14 suspends the schedule for a counted run of days: set a temperature and the resume time, then “Press HOLD twice” and pick the count. “Whatever temperature you set will be maintained 24 hours a day for the number of days you select. After this number of days have elapsed, the previously programmed schedule will resume at the time you set.” Back early? CANCEL or SCHED resumes it.

Screen Lock, Cleaning and Humidity

Page 16 covers tampering: “To prevent tampering, the screen can be partially or fully locked.” In partial lock, “the screen displays SCREEN LOCKED for several seconds if a locked key is pressed”, and any unlocked key clears it while that message shows. Full lock is absolute — “When the screen is fully locked, no keys function.” Both come from advanced function 0670 (page 25).

Cleaning has its own key: “Press SCREEN to lock the screen for cleaning. The screen will remain locked for 30 seconds so you can clean the screen without changing any settings” (page 17). On liquids: “Do not spray any liquid directly on the thermostat. Spray liquids onto a cloth, then use the damp cloth to clean the screen.”

Humidity is a select-models feature. “Select models can display the current indoor humidity level” (page 18), and “When humidity increases, the thermostat runs the air conditioner longer to reduce humidity” (page 19). With an outdoor sensor fitted, “the outdoor temperature is shown instead of the humidity level. Press MORE to display the humidity level.”

Advanced Functions

Entering setup is a two-key trick, not a menu button. Page 21: “1. Press SYSTEM.” then “2. Press and hold blank center key until the display changes.” The blank centre key is the space in the middle of the screen. The Honeywell TH8000 series advanced functions a homeowner needs:

Advanced functions quoted from pages 22-25
FunctionNameSettings in the manual
0160“Program schedule on/off”“0 Program schedule is off. Thermostat is non-programmable.” / “4 Program schedule is on (7-day programmable).”
0540“Program schedule periods”“2 Two program periods (Wake, Sleep)” / “4 Four program periods (Wake, Leave, Return, Sleep)”
0320“Temperature format (°F/°C)”“0 Fahrenheit” / “1 Celsius”
0670“Screen lock”“0 Screen is unlocked (fully functional)” / “2 Screen is fully locked”
0500“Furnace filter change reminder”“0 Off (no reminder to change furnace filter)” through “6 Reminder after 365-day run time (about 3 years)”
0510“Humidifier pad change reminder”“1 Reminder after 3 months” / “2 Reminder after 6 months” / “3 Reminder after 1 year”
0520“UV lamp change reminder”“1 Reminder after 1 year”
0120-0150Year, month and date settingsFour separate functions: the two year digits, month (1-12) and date (1-31)
0330“Daylight savings time on/off”“The thermostat is pre-programmed to automatically adjust to daylight savings time.”

Every reminder alert clears the same way: “Press RESET to cancel the alert”.

Batteries and Reset

Page 20 opens with the fact that surprises most owners: “Batteries are optional (to provide backup power) if your thermostat was wired to run on AC power when installed.” When the warning starts, “Install fresh batteries immediately when the LO BATT warning begins flashing.” Even without one, the standing advice is to “replace batteries once a year, or before leaving home for more than a month”, and TH8110U1003 battery replacement takes “3 fresh AAA alkaline batteries”.

There is no factory reset button in this document, so how to reset Honeywell VisionPro thermostat settings comes down to the levers the manual does give. To clear the schedule rather than the power, use function 0160: “0 Program schedule is off. Thermostat is non-programmable.” / “4 Program schedule is on (7-day programmable).” Because the clock “stores all date/time information”, a battery swap shouldn’t cost you the schedule.

In Case of Difficulty

For TH8110U1003 troubleshooting, page 26 opens with “If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.” and names five symptoms. Here is the manual’s own list, with only what this PDF copy prints as readable text:

The manual’s “In case of difficulty” symptoms, pages 26-27
SymptomWhat this copy of the manual reads
“Display is blank”Fixes are in the scrambled block; the readable tail says “batteries are correctly installed (see page 20).”
“No response to key presses (or temperature will not change)”Listed on page 26; read the bullets under it in your own copy.
“Backlight is dim”Listed on page 26, followed by the same readable “batteries are correctly installed (see page 20).”
“Heating or cooling system does not respond”Press SYSTEM once each way: “Make sure the temperature is set higher than the Inside temperature.” / “Make sure the temperature is set lower than the Inside temperature.”
“Heating or cooling system does not respond”If “Wait” is displayed, the readable tail gives “5 minutes for the system to restart safely, without damaging the compressor (see page 15).”
“Display shows Fan Auto and On or Auto and Circ at the same time”“If Auto and On is shown, the fan is scheduled for “On” during this period (see page 7).”

That gap is the honest limitation of this run: several pages of this PDF — the feature list on page 2, the preset temperatures on page 10 and most of the troubleshooting on page 26 — use a subset font with no usable text mapping, so they extract as scrambled glyphs. The symptom names above survived because they print in a normal font; the sentences under them did not. For those rows the paper manual is the authority.

Specifications

  • Document: Operating Manual, VisionPRO TH8000 Series Touchscreen Programmable Thermostat, number 69-1894EFS-03, 32 pages, © 2011 Honeywell International Inc.
  • Schedule: four periods a day, weekday and weekend settings, “7-day programmable” through function 0160.
  • Warranty: page 29 heads a “5-year limited warranty”, and the readable exclusion says “This warranty does not cover removal or reinstallation costs.”
  • Support: “call Honeywell Customer Care toll-free at 1-800-468-1502”.

FAQ

Can the TH8110U1003 run two stages of heating?

Not per this document, which assigns it one stage each way: “TH8110U: For 1 Heat/1 Cool systems”. The models in the same booklet that handle more are TH8320U and TH8321U, “For up to 3 Heat/2 Cool systems”.

Why does the screen say Wait after I turn the cooling on?

Compressor protection, which page 15 defines as a delay rather than a fault: “This feature forces the compressor to wait a few minutes before restarting, to prevent equipment damage.” Page 27 gives the number: “5 minutes for the system to restart safely, without damaging the compressor”.

Is there a TH8110U1003 wiring diagram in this manual?

No. This operating manual runs from clock setting to humidity control with no terminal chart; the only wiring language here is that the thermostat may have been “wired to run on AC power when installed”.

Does the TH8110U1003 work with an app?

The document never says so. Across all 32 pages there is no mention of Wi-Fi, a network, an app or a portal — your TH8110U1003 VisionPro manual PDF describes keypad-only operation.

What if the display goes blank?

Page 26 lists “Display is blank” first, and its readable fragment points at power: “batteries are correctly installed (see page 20).” The rest of that block is in the pages this copy can’t render as text, so confirm against the paper manual.