Category Archives: Thermostat

Honeywell Home T3 Pro Thermostat Installation Instructions Manual

Honeywell Home T3 Pro Thermostat Installation Instructions Manual

This page is for the Honeywell Home T3 Programmable Thermostat Installation Manual. The matching PDF on honeywellmanual.com is T3 Pro Thermostat Installation Instructions, document number 33-00520EFS-01 (M.S. 04-20, © 2020 Resideo Technologies, Inc.), a 36-page trilingual booklet with English on pages 1 to 12, French on pages 13 to 24, and Spanish on pages 25 to 36.

A note before you open the file: the “T3 Pro” line covers Honeywell Home’s non-programmable touchscreen thermostat, models TH3110U2008 and TH3210U2004. It has no weekly schedule; on the owner’s side you get a System mode selector, a Fan mode selector, and Installer Setup (ISU) for the technician. If the box says a programmable Honeywell Home model in the T5, T6, T9, or Wi-Fi 9000 family, this is the wrong document, and the model number printed behind the wallplate is the number to search instead.

Download T3 Pro Thermostat Installation Manual (PDF)

Contents

What Is in the Box

Page 1 lists the package contents directly. The T3 Pro box contains the thermostat itself, a UWP™ Mounting System, a small decorative cover plate sized 4.72″ H x 5.9″ W (120 mm x 150 mm), mounting screws and drywall anchors, two AA batteries, and the thermostat literature set (this Installation Instructions plus a user insert). If any item is missing, stop before drilling and check with the seller, because the UWP door and the R/Rc slider tab are both integral to the wiring steps.

Safety and Power Before You Start

Three cautions are printed on page 11 and govern the whole install. Quote them as written:

CAUTION: ELECTRICAL HAZARD. Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

CAUTION: EQUIPMENT DAMAGE HAZARD. Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

CAUTION: MERCURY NOTICE. If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

Both mounting pages open with the same operational rule: “Before starting, turn the power off at the breaker box or switch.” Do not rely on the wall switch alone when the air handler or furnace has a separate service switch.

Mounting the Thermostat

There are two mounting routes on pages 1 and 2, and you pick one depending on whether the old thermostat left marks on the drywall.

Optional cover plate installation. Use the cover plate when you need to hide paint gaps from the old thermostat. Mount the plate to the wall with any of its six screw holes, keeping it level and tightening without overtightening. Then hang the UWP on the top hook of the cover plate and snap its bottom into place. If there are no existing wall anchors, mark new holes and drill: 7/32″ (5.6 mm) for the red anchors and 3/16″ (4.8 mm) for the yellow anchors. The supplied screws pair by anchor color, #8 1-1/2″ (38 mm) with red and #6 1-1/2″ (38 mm) with yellow.

UWP Mounting System installation. Position the UWP on the wall, level it, mark both screw holes, and drill to the same 7/32″ or 3/16″ diameter depending on the anchor color. Pull open the UWP door and thread the wires through the wiring hole, then set the UWP over the anchors and tighten until the plate stops moving. Do not overtighten; close the door.

Final mounting on page 5: push excess wire back into the wall opening, close the UWP door so it sits flat without bulging, align the UWP with the back of the thermostat, and press gently until it snaps home. Then restore power at the breaker or switch.

Wiring: Terminals, Slider Tabs, and Diagrams

Power for the T3 Pro comes two ways at once. The UWP accepts a 24 VAC connection on R and C for primary power; the manual notes that C is optional if batteries are installed but is recommended. The two AA cells in the back cover primary or backup power. Wires release by pressing the terminal tab; never pull on the wire itself.

Page 3 lists every UWP terminal and what it does on a T3 Pro. Several are physically present but marked “Not used for T3 thermostat,” which is a common confusion when the old base has wires on them.

Terminal Function on a T3 Pro
R 24 VAC power from the heating transformer (shareable via slider tab)
Rc 24 VAC power from the cooling transformer (shareable via slider tab)
C 24 VAC common; for two-transformer systems, from the cooling transformer
W Heat (stage 1) on conventional systems. Do not use on heat pump applications
Y Compressor contactor, stage 1
G Fan relay
O/B Heat-pump changeover valve (configured in ISU 218)
AUX / W2 Auxiliary heat (TH3210U only)
E Emergency heat (TH3210U only)
S, L/A, A, Y2, U, K Not used for T3 Pro wiring (slider tabs on U terminals should stay in place)

The R/Rc slider tab. The UWP ships with a built-in jumper between R and Rc. If there is only one R wire, no matter whether it was landed on R, Rc, or Rh at the old thermostat, leave the slider in the up (one-wire) position. If one wire runs to R and a second to Rc, move the slider to the down (two-wire) position. The T3 Pro is a single-stage model, so the U-terminal slider tabs stay in place.

Pages 4 through 5 print wiring diagrams for eleven configurations. Conventional systems covered are 1H/1C with one transformer, 1H/1C with two transformers, heat-only, heat-only with fan, heat-only Series 20, heat-only power-open zone valve, and cool-only. Heat-pump systems covered are 1H/1C and 2H/1C with auxiliary heat (TH3210U only). Wire spec printed on page 4 is 18- to 22-gauge thermostat wire; shielded cable is not required.

System Modes and Fan Modes

Page 5 covers both selectors. Press Menu, then press the Mode (+) button to step through the available System modes, then press Done to lock one in. The manual lists these System modes: Auto, Heat, Cool, Em Heat (TH3210U only, on heat pumps with auxiliary heat, which locks out the compressor), and Off. It also notes that Heat On or Cool On may flash for five minutes because of compressor protection.

Press Menu, then the Fan (-) button to step through Fan modes. Auto runs the blower only when heating or cooling is active. On runs the blower continuously. If System is Off, the fan will still run when Fan is set to On.

Installer Setup (ISU) Reference

The T3 Pro enters ISU automatically the first time it is powered up after installation, and the manual tells the installer how to reach it later: hold the Menu button for about five seconds from the home screen. Inside ISU, press Edit (-) to change the value at the current step, press Next (+) to advance to the next setup number, and press Done to save and exit to the home screen. Every setup number is printed on pages 6 through 9. The table below collects the ones installers reference most; the numbers and defaults in bold match what the manual itself shows.

ISU number Purpose Options and notes
125 Temperature Indication Scale 0 = Fahrenheit, 1 = Celsius
200 Heating System Type 1 = Conventional forced-air heat, 2 = Heat pump, 3 = Radiant heat, 5 = None (Cool only); default varies by model
205 Heating Equipment Type (shown when 200 is Conventional or Radiant) Forced air: 1 = Standard-efficiency gas, 2 = High-efficiency gas, 3 = Oil, 4 = Electric, 5 = Hot-water fan coil. Radiant: 9 = Hot-water radiant, 12 = Steam
218 Reversing valve O/B (heat pump only) 0 = O (energized in Cool), 1 = B (energized in Heat)
220 Cool stages / Compressor stages 0 or 1 (set to 0 if there is no compressor or cooling stage)
221 Heat stages / Backup heat stages Heat fixed at 1; Backup heat 0 or 1
230 Fan control in Heat (shown when 205 is Electric forced air or Fan coil) 1 = Equipment controls fan, 2 = Thermostat controls fan
300 System changeover 0 = Manual, 1 = Automatic (turns the Auto System mode on the home screen)
303 Auto changeover differential 0 to 5 °F (0 to 2.5 °C). The manual distinguishes this from deadband, which is fixed by firmware and not adjustable
340 Backup heat droop (TH3210U only) 0 = Comfort, or a set droop from 2 °F up to 15 °F
350 Upstage timer to backup heat (TH3210U only) 0 = Off, 1 = 30 min, 2 = 45 min, 3 = 60 min, and so on up to 5 hours
365 Compressor cycle rate, stage 1 1 to 6 cycles per hour, shown only when Cool / Compressor Stage is set to 1
370 Heating cycle rate, stage 1 1 to 12 CPH. Defaults the manual lists by equipment: standard gas 5, high-efficiency gas 3, oil 5, electric 9, fan coil 3, hot-water radiant 3, steam 1
375 Heating cycle rate, auxiliary heat (TH3210U only) 1 to 12 CPH
387 Compressor protection 0 = Off, 1 to 5 minutes. When a call arrives during the delay the screen shows “Wait”
430 Minimum Cool setpoint 50 to 99 °F (10.0 to 37.0 °C); default 50 °F
431 Maximum Heat setpoint 32 to 90 °F (0 to 32.0 °C); default 90 °F
1400 Backlighting 0 = On demand, 1 = Continuous (requires a C-wire)
1401 Backlight brightness 1 to 5, shown only when Continuous is selected
1420 Temperature display offset -3 to +3 °F (-1.5 to +1.5 °C); 0 means the reading is unaltered

The manual closes ISU with a plain sentence: “You have now finished installing and setting up your thermostat.” There is no owner-side reset procedure in this booklet; if a full ISU wipe is needed, that is an installer task.

Specifications and Electrical Ratings

Page 10 lists the ratings that govern where the thermostat can be used.

Specification Value from the manual
Heat setpoint range 32 °F to 90 °F (0 to 32.0 °C)
Cool setpoint range 50 °F to 99 °F (10.0 to 37.0 °C)
Operating ambient temperature 32 °F to 102 °F (0 to 38.9 °C)
Shipping temperature -20 °F to 120 °F (-28.9 to 48.9 °C)
Operating relative humidity 5% to 90%, non-condensing
Thermostat size (H x W x D) 3.86″ x 5.36″ x 1.08″ (98 x 136 x 27.4 mm)
Decorative cover plate, small 4.72″ x 5.9″ (120 x 150 mm)
Terminal voltage (50/60 Hz) All outputs are rated 20 to 30 VAC
Running current, W / W2 (Aux) / Y 0.02 to 1.0 A (W2 is TH3210U only)
Running current, E / G / O/B 0.02 to 0.5 A
Wire gauge 18 to 22 gauge, unshielded

Troubleshooting

Page 10 carries the manual’s own short troubleshooting table. It is reproduced here with the exact fixes the manual gives; nothing is added.

Problem What the manual advises
Display is blank Check the circuit breaker and reset if necessary. Make sure the power switch for the heating and cooling system is on. Make sure the furnace door is closed securely. Make sure two fresh AA alkaline batteries are correctly installed (page 2).
Heating or cooling system does not respond Press the Mode button to set System to Heat (page 5) and make sure the desired temperature is set higher than the inside temperature. To test cooling, press Mode to set System to Cool and make sure the desired temperature is set lower than the inside temperature. Check the circuit breaker and reset if necessary. Make sure the power switch at the heating and cooling system is on. Make sure the furnace door is closed securely. Wait five minutes for the system to respond.
“Cool On” or “Heat On” is flashing The compressor protection feature is engaged. Wait five minutes for the system to restart safely, without damage to the compressor.
Aux heat runs during cooling For heat pump systems, verify there is no wire attached to W on the UWP. See “Wiring heat pump systems” on page 4.
Cool runs on a call for heat For heat pump systems, verify there is no wire attached to W on the UWP. See “Wiring heat pump systems” on page 4.

Getting Help and Warranty

Page 11 directs support questions to customer.resideo.com or Honeywell Customer Care at 1-800-468-1502, and the same page shows how to pull the thermostat off the UWP for a service call. The footer on page 12 lists the Resideo mailing address, 1985 Douglas Drive North, Golden Valley, MN 55422, and identifies the document as 33-00520EFS-01, marking revision M.S. 04-20, © 2020 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International, Inc.; the product itself is manufactured by Resideo Technologies, Inc. and its affiliates.

Because this document is a T3 Pro installation booklet, it does not carry a homeowner-side warranty statement. For warranty terms on a specific T3 Pro unit, check the printed card that shipped in the box or contact Honeywell Customer Care with the model number (TH3110U2008 or TH3210U2004) from the back of the thermostat.

Honeywell TH9320WF5003 WiFi 9000 Color Touchscreen Thermostat User Manual

Honeywell TH9320WF5003 WiFi 9000 Color Touchscreen Thermostat User Manual

The Honeywell Home TH9320WF5003 User Manual is Resideo’s owner guide for the Wi-Fi 9000 Color Touchscreen Thermostat. The document number is 69-2814EFS; the current printing is revision -12 with the cover mark M.S. Rev. 04-22 and copyright 2022 Resideo Technologies, Inc. Earlier printings (-05 and -07) carry the same core content with a Honeywell International copyright line.

A naming note that trips people up: the TH9320WF5003 is the Wi-Fi 9000 model, not the T9 Smart. Honeywell reused the TH9320 prefix across both, but the two lines use different apps and different hardware. The 9000 works through the Total Connect Comfort service in a browser or its mobile app; the T9 (TH9320WF3004) uses the Resideo app and pairs with the smart room sensors. If the box says “Wi-Fi 9000,” this manual is the one to use.

Scope of the guide: physical install is documented in a separate Installation Instructions booklet. The User Manual assumes the thermostat is already on the wall and covers Wi-Fi connection, registration with Total Connect Comfort, time and date, fan and system mode, the seven-day program schedules, temporary and permanent hold, vacation, business-mode holiday and occupancy features, screen color, preferences, and cleaning. Terminal assignments, wiring, and commissioning values belong to the install guide.

Key Features of the TH9320WF5003

The manual’s front matter (page 2) opens with what the thermostat can do once it is connected. Read it alongside Honeywell’s own product listing to confirm the underlying hardware:

  • Wi-Fi 2.4 GHz (802.11b/g/n) with Total Connect Comfort. Register the unit at mytotalconnectcomfort.com using the MAC ID and CRC printed on the thermostat.
  • Remote control and monitoring. View and set temperature and schedules from a browser or mobile app; automatic software updates over Wi-Fi.
  • Email alerts and outdoor weather. The manual notes that email alerts and the outdoor temperature and humidity display require Wi-Fi setup and registration.
  • 7-Day programmable. Selectable to 7-day programming or non-programmable. Four periods per day (Wake, Leave, Return, Sleep) with different weekday and weekend programs.
  • Color touchscreen. A large backlit display with customizable color themes; the screen can be set to match décor.
  • Multi-stage support. Rated for 24 V low-voltage HVAC systems, up to 3 heat / 2 cool on heat pump or 2 heat / 2 cool on conventional systems. The install guide covers terminals R, RC, C, W (or O/B), W2 (or AUX/E), Y, Y2, G, L, and K.
  • Home and Business modes. The manual carries a Business-screen quick reference alongside the Home layout, and Business-mode features such as Holiday/Event Scheduler, Custom Events, and Occupancy Mode.
  • Awareness features. Equipment status screen, filter and battery reminders, keypad lockout, and cleaning lock.

Document Structure

The 69-2814EFS User Guide is organized by task, and the printed page references below match the manual’s own table of contents. Knowing which page holds which feature makes it easy to answer questions on the phone or in a service ticket.

  1. About your new thermostat. What you can do through Total Connect Comfort, plus the Home-screen and Business-screen quick reference pages.
  2. Setting up your thermostat. Connecting to Wi-Fi (MENU, then Wi-Fi Setup), entering the network password, and confirming the “Connection Successful” screen.
  3. Registering your thermostat online. Creating or signing in to a My Total Connect Comfort account, then entering the MAC ID and CRC identifiers to bind the unit.
  4. Daily operation. Setting the time and date, setting the fan (On, Automatic, Circulate, or Follow Schedule), setting the system mode (Heat, Cool, Off, or Automatic), and reading the presets.
  5. Programming schedules. Preset energy-saving schedule, adjusting program schedules, and overriding schedules in Home or Business mode.
  6. Away and special situations. Vacation hold (home use), holiday and event scheduling, custom events, holiday override, and initiating occupancy mode (business use).
  7. Look and feel. Equipment status, customizing screen color, setting preferences, adjusting security (keypad lock), and cleaning the thermostat screen.
  8. Reference. Glossary, Regulatory Information (FCC Part 15.19, 15.21, 15.105(b) Class B; Industry Canada RSS-GEN 7.1.2 and 7.1.3), and the Resideo address block.

Wi-Fi Setup and Total Connect Comfort

The manual treats Wi-Fi and registration as two connected steps. Do them once, and every feature behind “remote access, alerts, and outdoor weather” unlocks.

  1. On the touchscreen, press MENU, then touch Wi-Fi Setup. The screen shows “Searching for wireless networks. Please wait…” then a list of available networks.
  2. Pick your network. Use the on-screen keyboard to type the Wi-Fi password, then touch Done. The unit replies “Connecting to your network. Please wait…” and then a “Connection Successful” screen.
  3. Press Next to reach the registration information screen. If you dismiss it before finishing, an orange alert appears on the home screen reminding you to register.
  4. In a browser, go to mytotalconnectcomfort.com, create or sign in to an account, and follow the Add Thermostat prompts. Enter the MAC ID and CRC that the thermostat displays; these are the unique identifiers that bind the unit to your account.
  5. After the site confirms the thermostat, the Total Connect Comfort screen displays SUCCESS and you can control the thermostat from the browser or the My Total Connect Comfort mobile app.

Programming and Daily Use

The Wi-Fi 9000 ships with a four-period preset schedule the manual prints on page 18. Weekday (Mon-Fri) values are Wake 6:00 a.m. at 70° heat / 78° cool, Leave 8:00 a.m. at 62° / 85°, Return 6:00 p.m. at 70° / 78°, and Sleep 10:00 p.m. at 62° / 82°. The Saturday-Sunday program uses the 6:00 a.m. and 10:00 p.m. periods at the same temperatures.

To change the schedule, follow the “Adjusting program schedules” steps in the manual:

  1. Touch MENU, then Create/Edit Schedule.
  2. Pick the mode: View/Edit for a quick change, Guide Me for the interview-style builder, or I’ll do it myself for full control.
  3. In “I’ll do it myself,” select the days you want to edit, then touch Next.
  4. Set the Wake time, then the heat and cool temperatures for that period. Touch Done to confirm.
  5. Repeat for LEAVE, RETURN, and SLEEP. Touch DELETE PERIOD to remove a period you do not want.
  6. Touch Done again to save and exit.

Everyday comfort tweaks use HOLD rather than editing the schedule. From the home screen, touch the temperature area to set a temporary hold with a “Hold Until” time; the schedule resumes when that time expires. Touch the option to switch to a permanent hold if you want the setting to stay until you resume the program schedule. In Business mode the hold duration is capped by the Override Duration value in Advanced Preferences.

Business installations get extra tools the manual walks through: a Holiday/Event Scheduler that can apply U.S. or Canadian holidays, custom one-off events scheduled by specific date or by month/weekday, a holiday override for an unplanned closure, and an Occupancy Mode that keeps the space at an energy-saving level until someone presses the button on arrival. The Home-use vacation-hold feature is simpler: MENU, then Vacation Mode, then the date you leave and the date you return.

Two maintenance touches round out daily use. Press MENU and select Equipment Status to see which heating, cooling, or fan outputs the thermostat is running right now. Press MENU and select Color Themes to change the screen to match the room, or to define a custom background and text color.

Important Safety Notices

The 69-2814EFS User Guide is not a wiring document. Wiring and commissioning safety belong to the Installation Instructions, and Honeywell Home’s thermostat support pages carry the standard warning verbatim:

Warning! Improper wiring or commissioning of your thermostat can cause unintended operation of your HVAC system which could lead to property damage, injury, including death. If you are unsure of what type of system you have, refer to your heating/cooling system equipment literature or call an HVAC professional.

  • 24 V systems only. The TH9320WF5003 is a low-voltage thermostat. It is not built for a 120/240 V line-voltage circuit such as electric baseboard heat, and it is not rated for the same terminals as a line-voltage controller.
  • Have wiring checked if you are unsure. The manual’s system-mode pages assume the install guide’s wiring was done correctly. If heat and cool behave as mirror images of each other, or if an unexpected output runs, stop and re-check terminal assignments against the install guide rather than adjusting settings at the touchscreen.
  • Screen cleaning. The “Cleaning the thermostat screen” page in the guide walks through the clean-screen lock so the display does not accept touches while you wipe it.

Where the User Guide does not answer a question (wiring, terminal map, installer setup codes, or a specific error on screen), consult the Installation Instructions or Resideo Customer Care before opening the unit.

Getting Help

The user guide prints two contact points on different pages. Its Total Connect Comfort section directs users to http://yourhome.honeywell.com and to 1-855-733-5465 for help registering the thermostat and using remote features. The -12 revision footer adds the Resideo Customer Care number 1-800-468-1502 and the mailing address at 1985 Douglas Drive North, Golden Valley, MN 55422. Have the model number, the MAC ID and CRC, and a photo of your wiring (only for install questions) ready before you call.

Two things worth knowing if you are shopping or replacing. Honeywell Home lists a 5-year limited warranty on this model. SupplyHouse’s listing also shows the unit as discontinued as of August 25, 2026, with the RTH9585WF1004 and TH9320WFV6007 listed as replacements. If you are troubleshooting an existing install rather than buying new, the guide is still the reference for programming, Total Connect Comfort, and Business-mode features.

Skip to PDF content
Honeywell FocusPro TH6320R Operating Manual

Honeywell FocusPro TH6320R Operating Manual

​Download the Honeywell FocusPro TH6320R Operating Manual (PDF)​

The file holds 21 pages of English. The contents list points to Spanish at page 20, French at page 40 and regulatory information at page 60, none of which are in this file. The inside cover carries the Quick Reference Card, which pulls out from under the body, and the help line 1-800-468-1502. It also warns against running cooling when the outdoor temperature is below 50°F (10°C), to prevent possible compressor damage.

Table of Contents

What the FocusPro TH6320R Is

Page 2 reduces the setup to four steps: set the time and day, which the booklet marks as required for proper operation; select the fan setting; select the system setting; and check the program schedules, which are preset to energy-saving levels on the assumption that the household wakes at 6 am, leaves at 8 am, returns at 6 pm and goes to bed at 10 pm. The same page notes that the schedule can be overridden at any time with one-touch temperature control. The contents list runs from programming and operation through to battery replacement, difficulty, warranty and regulatory information, and it contains no installation or wiring section.

The thermostat is the wireless part of the system. It reports a lost radio link as No Signal and restores that link by itself once power returns. The booklet also covers an optional remote control and an optional outdoor air sensor, and treats both as additions rather than requirements.

Controls and Display

Page 3 names five parts. There is the digital display, the battery holder at the side of the body, the up and down temperature buttons and the HOLD button. The last of the five is a row of four function buttons along the bottom, whose labels change with the task and appear on screen just above each button. Those labels are SET CLOCK/DAY/SCHEDULE, SET DAY, SET SCHEDULE, DONE, NEXT, CANCEL PERIOD, CANCEL, MORE and FIND REMOTE, depending on the screen.

Page 4 maps the display field by field.

Display itemWhat it showsPage
System settingHeat, Cool, Auto, Off or Em Heat7
Fan settingAuto or On6
Current program periodWake, Leave, Return or Sleep8-9
Set Clock/Day/ScheduleEntry point for the clock, the day and the schedule5, 9
Current inside temperatureThe measured room temperature–
RecoveryShown while Adaptive Intelligent Recovery is working15
Low battery warningsThermostat and outdoor sensor cells16-17
System statusHeat On or Cool On, flashing during compressor protection15
Auxiliary heatOnly for heat pumps with auxiliary heat–
MoreOutdoor climate if a sensor is installed, or find a misplaced remote14
Current time and dayThe clock setting5
Temperature settingThe setpoint in use9-11

Setting the Time and Day

Press SET CLOCK/DAY/SCHEDULE and use the arrows to set the clock. Press SET DAY and use the arrows to select the day of the week. Press DONE to save.

Two notes sit under the steps. If the SET CLOCK/DAY/SCHEDULE option is not displayed, press DONE or CANCEL. If the display flashes Set Clock, the thermostat follows the settings for the weekday Wake period until the time and day are reset.

Fan, System and Auto Changeover

FAN selects Auto or On. In Auto, which the booklet calls the most commonly used setting, the fan runs only when the heating or cooling system is on; on On it runs continuously. Options may vary with the equipment.

SYSTEM selects Heat, Cool, Off, Auto or Em Heat. Heat controls only the heating system and Cool only the cooling system, while Off turns all systems off. Auto lets the thermostat choose heating or cooling according to the indoor temperature. Em Heat applies only to heat pumps with auxiliary heat: it controls emergency and auxiliary heat with the compressor locked out.

Auto changeover is the feature behind Auto, and the booklet gives it to climates where air conditioning and heating are used on the same day. Heat and cool settings must be at least 3 degrees apart, and the thermostat adjusts them to keep that separation. The Auto setting may not appear at all, depending on how the thermostat was installed.

The Preset Schedule

The page heading reads Energy-saving settings for maximum cost savings. The booklet states that the preset can reduce heating and cooling expenses by as much as 33%. Four periods run through the day: Wake at 6:00am, Leave at 8:00am, Return at 6:00pm and Sleep at 10:00pm.

PeriodHeat (Mon-Fri)Cool (Mon-Fri)Heat (Sat-Sun)Cool (Sat-Sun)
Wake (6:00 am)70°F78°F70°F78°F
Leave (8:00 am)62°F85°F62°F, or cancel period85°F, or cancel period
Return (6:00 pm)70°F78°F70°F, or cancel period78°F, or cancel period
Sleep (10:00 pm)62°F82°F62°F82°F

The cancel option appears only on the two middle periods of the weekend columns.

Editing, Overriding and Holding

To change a time or temperature, press SET CLOCK/DAY/SCHEDULE and then SET SCHEDULE. Use the arrows to set the weekday Wake time and press NEXT, then the arrows for that period’s temperature and NEXT again. Repeat for Leave, Return and Sleep, press NEXT to reach the weekend periods, and DONE to save and exit. The three buttons on this screen are DONE, CANCEL PERIOD and NEXT, and a note asks you to confirm that the thermostat is set to the system you intend to program, Heat or Cool.

The arrows also work during normal operation. Pressing one adjusts the temperature at once and overrides the current period only; the display shows the new setting with Hold Until and the time that period ends, and CANCEL returns the schedule immediately.

HOLD is the permanent version. It overrides the temperature settings for every period, turning the schedule off so the thermostat can be adjusted by hand. Whatever temperature is set is maintained 24 hours a day until it is changed or CANCEL is pressed.

Remote Control and Outdoor Sensor

An optional remote control can act as a mobile thermostat, holding a comfortable temperature as you move between rooms. While the system responds to temperatures measured at the remote, the display reads Remote has Control, and CANCEL hands control back to the thermostat. The booklet warns that the thermostat may take up to 15 seconds to respond to commands entered at the remote, and refers to a separate Remote Control Operating Manual.

With an outdoor air sensor fitted, MORE shows the outdoor temperature and humidity, and DONE exits. MORE then FIND REMOTE makes a misplaced remote beep for two minutes; pressing anywhere on the display stops the beeping.

Special Features and Batteries

Built-in compressor protection keeps the compressor from restarting too soon after shutdown. It forces a wait of a few minutes, and during that time the display flashes Cool On, or Heat On on a heat pump. Adaptive Intelligent Recovery lets the thermostat learn how long the furnace and air conditioner take to reach the programmed settings. The temperature then arrives at the time you set, and the word Recovery appears while the feature is working.

REPLACE BATTERY begins flashing about two months before the cells are depleted, and the inside cover puts the interval at once a year. Remove the battery holder and fit 2 fresh AA alkaline batteries, and communication with the wireless network resumes within a few minutes. The note adds that batteries inserted within 2 minutes, printed as t2 minutes, save the time and day from being reset, while all other settings stay in memory either way. The outdoor air sensor takes 2 fresh AA lithium batteries and has its own REPLACE BATTERY OUTDOOR warning with the same two-month lead. It is reloaded by taking the sensor off its bracket and removing the cover.

In Case of Difficulty

Page 18 prints two entries in two columns, symptom on the left and action on the right.

SymptomWhat to do
Heating or cooling system does not respond
  • Check circuit breaker and reset if necessary.
  • Make sure power switch at heating & cooling system is on.
  • Make sure furnace door is closed securely.
  • Wait 5 minutes for the system to respond.
Screen displays “No Signal”

Thermostat has lost radio contact with the wireless network (usually because of a power outage). To restore power:

  • Check circuit breaker and reset if necessary.
  • Make sure power switch at heating & cooling system is on.
  • Make sure furnace door is closed securely.

After power is restored, the thermostat will automatically restore wireless communication within a few minutes.

The warranty runs three years from the date of purchase, excluding the battery, and extends to five years once the product is registered online at www.warranty.Honeywell.com. A defective unit goes back to the place of purchase with a bill of sale, or through Honeywell Customer Care on 1-800-468-1502, which decides whether it is returned to Golden Valley, Minnesota, or replaced. Removal and reinstallation costs are not covered. Canadian owners are given a Toronto address for written enquiries.

Frequently Asked Questions

Do I have to program the thermostat before using it?

No. The thermostat is pre-programmed with energy-saving settings, and only the time and day must be set for proper operation. After that, check the fan setting, the system setting and the schedule.

How far apart must the heat and cool settings be in Auto?

At least 3 degrees. The thermostat adjusts the settings itself to keep that separation, and the Auto setting may be missing entirely depending on how the thermostat was installed.

What is the difference between the arrows and HOLD?

The arrows override only the current period, and the display counts down to the time it ends with Hold Until. HOLD overrides every period and keeps one temperature 24 hours a day until you change it or press CANCEL.

Which batteries does it take?

Two AA alkaline in the thermostat, fitted in the battery holder at the side of the body. The outdoor air sensor takes two AA lithium, a different type, and warns through its own REPLACE BATTERY OUTDOOR message.

Why is Cool On flashing?

The built-in compressor protection is holding the compressor for a few minutes after shutdown, and the message flashes during that wait. On a heat pump the same state shows Heat On.

Honeywell Aquastat L4006A Installation Instructions

These boiler-mounted, immersion type controllers operate in response to temperature changes in hydronic heating systems. The L4006 family covers high limit, low limit and circulator duty on hydronic boilers, in immersion well and surface mount versions. This page reproduces form 60-0915—06 in full, including the heat-conductive compound material safety data sheet that ships with the immersion well models.

Internal view of the L4006A,B Aquastat controller with the case open, showing the setpoint indicating dial, differential adjustment wheel, adapter clamp screws and horizontal immersion well
Fig. 1. Internal view of L4006A,B with horizontal well. L4006E is the same with reset button added.

Application

Model Switch action How it is used
L4006A Breaks the circuit on a temperature rise to the control setting. High limit or low limit control. When used as a controller or as a low limit, a separate high limit must be used.
L4006B Makes the circuit on a temperature rise. Circulator controller, delaying circulator operation when boiler water temperature is below the control setting.
L4006E Breaks the control circuit when the controlled medium reaches the high limit setting; trip-free manual reset. A reset button on the front of the case must be pressed to re-establish the control circuit.
L4006H Breaks the control circuit at the high limit setting; trip-free manual reset, as on the L4006E. Includes bracket and clamp for surface mounting on pipe or tank.

A plastic bag of heat-conductive compound is included with the L4006A,B,E Aquastat® Controllers for use when the sensing bulb is inserted into a well designed for a large bulb than the one used on the L4006A,B,E. A 124904 Well Adapter, for use on old wells that do not fit the L4006A,B,E immersion well clamp, can be ordered; see form 68-0040, Wells and Fittings for Temperature Controllers. A setting stop is included to prevent setting above a desired temperature on limit.

If a well adapter or other accessories are needed, refer to form 68-0040, Wells and Fittings for Temperature Controllers, for part numbers and ordering information.

Installation

WARNING — Electrical shock hazard. Can cause serious injury, death or equipment damage. Disconnect the power supply before beginning installation to prevent electrical shock or equipment damage.

When installing this product…

  1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
  2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.
  3. Installer must be a trained, experienced service technician.
  4. After installation is complete, check out product operation as provided in these instructions.

Installing immersion well models (L4006A,B,E)

Important: Obtain the best thermal response with a well that snugly fits the sensing bulb. The bulb should be inserted until it rests against the bottom of the well. Use a well of correct length and bend the tubing, if necessary, to provide enough force to hold the bulb against the bottom of the well. Do not make a sharp bend in the tubing. A sharp bend can produce a break in the tubing and cause a loss of fill. This condition will cause the high and low limit controls to be made continuously.

If the well is not a snug fit on the bulb, use the heat-conductive compound as follows. Fold the plastic bag of compound lengthwise and twist gently. Snip the end of the bag and insert into the well. Slowly pull out the bag while squeezing firmly to distribute the compound evenly in the well. Insert the bulb into the well. Bend the tubing, if necessary, to provide force to hold the bulb against the bottom of the well and to hold the out end of the bulb in firm contact with the side of the well. Wipe off any excess compound.

Note: Some models have an adjustable capillary tubing length to 3 inches (76 mm). In these models, pull out extra tubing from inside the case, if needed.

Follow the boiler manufacturer instructions, if available; otherwise, proceed as follows.

  1. Remove the old control.
  2. Refer to the cover insert of the old control to identify and tag each lead as it is disconnected.
  3. Leave the old well in place if it is suitable.

If the well is otherwise suitable but does not fit the L4006 immersion well clamp

Use a 124904 Well Adapter (order separately, see form 68-0040) to secure the L4006 to the old well. The adapter has a flange at one end for fastening the L4066 adapter clamp.

  1. Loosen, but do not remove, the two adapter clamp screws (see Fig. 1).
  2. Slide the adapter onto the capillary and short tube; see Fig. 2 inset.
  3. Make sure the flanged end of the adapter fits into the hole in the case. Position the adapter well clamp snugly over the flange on the adapter, then tighten the clamp screws.
  4. Insert the bulb into the well, as shown in Fig. 2. If necessary, use the heat-conductive compound as instructed in the IMPORTANT statement above.
  5. Tighten the setscrew (if one is present in the old well spud) against the adapter.

If the old well is unsuitable

  1. Drain the system and remove the well.
  2. Select a new well from form 68-0040 (order well separately).
  3. Install the new well, refill the system and check for leaks.
  4. Loosen, but do not remove, the two adapter clamp screws (Fig. 1).
  5. Insert the sensing bulb into the well until it bottoms as show in Fig. 2. Add heat-conductive compound, if necessary, as instructed in the IMPORTANT statement above.
  6. Make sure the end of the well fits into the hole in the case. Position the immersion well clamp snugly over the well flange and tighten the clamp screw securely.
Sectional drawing of the sensing bulb inside an immersion well, showing the well adapter, adapter clamp, capillary tube, setscrew and heat-conductive compound, with an inset of the back of the case
Fig. 2. Bulb in immersion well and use of adapter.
Diagram notes (text version)
  • Slightly bend in tubes should hold bulb in good thermal contact with the well at two opposite points, as in (A) and (B).
  • Assure that tubes fit freely in adapter so that tension of the capillary tube at point (C) holds the sensing bulb in good thermal contact with the bottom of well at point (D).

Surface mounting the L4006H

The L4006H is designed for surface mounting on piping or tank and can be mounted in any position.

When mounting the L4006H on piping, the pipe should be 1 in. (25 mm) diameter or larger for accurate temperature sensing.

  1. Remove any insulation from the pipe.
  2. Thoroughly scrape off all scale, rust or paint.
  3. Mount controller as shown in Fig. 3 using adjustable 12 in. (294 mm) pipe strap furnished.

When mounting the L4006H on a tank, use a pipe strap of appropriate length, approximately 6-10 ft (17.6- 29.4m) for the tank (not provided). Fit the pipe strap through the slot in the mounting bracket. See Fig. 3.

L4006H controller case fastened to a vertical pipe with the 12 inch adjustable pipe strap and mounting bracket
Fig. 3. Mount L4006H directly on surface.

Wiring

WARNING — Electrical shock hazard. Can cause serious injury, death or equipment damage. Disconnect power supply before connecting wiring to avoid electrical shock or equipment damage.

All wiring must comply with local codes and ordinances regarding wire size, insulation, enclosure, etc. See Fig. 4 and 5 for typical diagrams of Aquastat® Controllers used in heating systems.

Use these Aquastat Controllers with copper wire only.

Typical hookup diagram for a gas-fired system with domestic hot water: 24 volt thermostat, low water cutoff, pressure control, L4006A or L4007A low limit Aquastat controller, gas valve and Pilotstat control
Fig. 4. Typical hookup for gas-fired system with domestic hot water.
Diagram notes (text version)
  • Power supply. Provide disconnect means and overload projection as required.
  • Use L4006E for manual reset.
Hookup diagram for an oil-fired summer-winter hydronic system with domestic hot water: RA832A switching relay, high limit and low limit Aquastat controllers, circulator Aquastat controller, ignition, circulator, burner and Protectorelay control
Fig. 5. Hookup for oil-fired, summer-winter, hydronic system with domestic hot water. This is typical where control for domestic hot water is added, or where each Aquastat Controller is mounted in a separate location.
Diagram notes (text version)
  • Power supply. Provide disconnect means and overload protection as required.
  • Use L4006E for manual reset.

Operation

For proper selections of settings, follow boiler manufacturer recommendations:

  1. High limit controller: Shuts off burner when water temperature exceeds high limit setting. Burner restarts when temperature drops to high limit setting minus the temperature differential.

Note: If L4006E or H, see Manual Reset section.

  1. Low limit controller: Maintains minimum boiler temperature for domestic hot water. Turns boiler on at temperature setting, less differential.
  2. Circulator controller: Prevents circulation of water that is not hot enough. Breaks circulator circuit at temperature setting minus differential and remakes at setting.

Adjustment

Set the differential to correspond with the boiler manufacturer recommendations. To adjust models with adjustable differential, rotate the wheel on the back of the snap switch until the desired reading is aligned with the V notch in the frame. The wheel provides an adjustment from 5°F to 30°F (3°C to 17°C). Replace the cover on the Aquastat Controller.

Adjust the control point to correspond with the boiler manufacturer recommendations. To adjust, insert a screwdriver in the slotted screw type head located beneath the window in the cover. Turn the scale to the desired control point.

Manual reset

When the device includes manual reset (L4006E and H), be sure to press the red reset button on the front of the case to make sure that the controller is not locked out on safety. When checking out the system, adjust the control point low enough so the temperature of the controlled medium reaches the high limit setting, the burner shuts off, and the Aquastat Controller locks out. When the temperature of the controlled medium drops to the high limit setting minus differential, push the manual reset button and the system should be operative again. Reset control to proper high limit setting.

Checkout

Check to make certain that the Aquastat Controller has been installed and adjusted properly. Put the system into operation and observe the action of the device through several cycles to make certain that it provides proper control of the system as described in the Operations section. Further adjustments can be made to meet more exact comfort requirements.

Heat-conductive compound: material safety data sheet (DS9021)

Section 1. Product and company identification

  • Product name: Heat Conductive Compound
  • MSDS ID: DS9021
  • Synonyms: MS1699
  • Product use: Heat conductive material used to enhance contact and heat transfer in temperature sensor applications.
  • Manufacturer: Resideo Technologies Inc., 1985 Douglas Drive North, Minneapolis, MN 55422.
  • Date released: October 8, 1999
  • Customer Response Center: 800-328-5111
  • Emergency telephone information: 888-809-3787
  • NFPA ratings: Health 0; Flammability 1; Reactivity 0; Personal Protection B

Section 2. Composition, information on ingredients

Ingredient CAS number Percent PEL TVL
#2 Lithium Complex Grease (70%):
Mineral Oil 64742-65-0 35-50 5 mg/m3 5 mg/m3
Mineral Oil 64742-62-7 20-25 5 mg/m3 5 mg/m3
Lithium Hydrostearate/Sebacate Complex 68815-49-6 4-9 — —
Zinc Alkyldithiophosphate 68649-42-3 0-2 — —
Aluminum Paste (30%):
Aluminum, as Al 7429-90-5 20-25 15 mg/m3 10 mg/m3
Aliphatic Petroleum Distillates 8052-41-3 10-15 2900 mg/m3 525 mg/m3
Stearic Acid 57-11-4 1-2 — —
Aromatic Petroleum Distillates 64742-95-6 1-2 5 mg/m3 5 mg/m3

Additional information: Part No. 120650 (0.5 oz tube); Part No. 107408 (4 oz can); Part No. 197007 (5 gallon container). May also contain minute amounts of lithium and molybdenum lubricant compounds.

Section 3. Hazard identification

Acute health effects

  • Skin: Excessive contact may cause skin irritation and dermatitis.
  • Eye: Direct contact with eye will cause irritation.
  • Inhalation: No adverse effects are expected.
  • Ingestion: Ingestion of product may cause nausea, vomiting and diarrhea.

Chronic health effects

  • Existing skin rash or dermatitis may be aggravated by repeated contact.
  • OSHA hazard classifications: None.
  • Carcinogenicity: Not considered to be a carcinogen by either OSHA, NTP, IARC, or ACGIH.

Section 4. First aid measures

  • Eye contact: Flush eyes with water for 15 minutes. Remove any contact lenses and continue to flush. Obtain medical attention if irritation develops and persists.
  • Skin contact: Remove excess with cloth or paper. Wash thoroughly with mild soap and water. Obtain medical attention if irritation develops and persists.
  • Ingestion: Contact physician or local poison control center immediately.
  • Inhalation: Remove patient to fresh air and obtain medical attention if symptoms develop.

Section 5. Fire fighting measures

  • Material flash point: > 383°F (195°C). Will burn if exposed to flame.
  • Extinguishing media: Carbon dioxide, dry chemical or foam.
  • Special fire fighting procedures: None.
  • Explosion hazards: None. Aluminum powder can react with water to release flammable hydrogen gas. In the form of this product, this reaction is not expected.

Section 6. Accidental release measures

Scrape up and dispose of as solid waste in accordance with state and federal regulations.

Section 7. Handling and storage

Store in dry place. Keep container closed when not in use.

Section 8. Exposure controls and personal protection

  • Ventilation: No special ventilation is required when working with this product.
  • Respiratory protection: None required.
  • Eye protection: Not normally required. However, use chemical safety goggles or faceshield if potential for eye contact exists, especially if material is heated.
  • Hand/clothing protection: Not normally required. Protective gloves and clothing are recommended, as material is difficult to remove from skin and clothing.
  • Other protective equipment: None required.

Section 9. Physical and chemical properties

  • Appearance/odor: Aluminum color, semi-solid material, pleasant odor.
  • Solubility in water: Negligible.
  • Specific gravity: 0.86.

Section 10. Stability and reactivity

  • Stability: Stable.
  • Reactivity: Hazardous polymerization will not occur.
  • Incompatibilities: Strong oxidizing agents and halogens.
  • Hazardous decomposition products: Carbon dioxide, carbon monoxide.

Section 11. Toxicology information

No data available.

Section 12. Ecological information

Chemical fate information: Hydrocarbon components will biodegrade in soil; relatively persistent in water.

Section 13. Disposal consideration

Dispose of as solid waste in accordance with local, state and federal regulations.

Section 14. Transportation information

DOT classification: Not classified as hazardous.

Section 15. Regulatory information

SARA Title III supplier notification: Include in Section 311/312 inventory reports if amounts exceed 10,000 pounds. Aluminum compounds are subject to the reporting requirements under Section 313 of Emergency Planning and Community Right-To-Know Act of 1986 (40 CFR 372). Ingredients listed in TSCA Inventory.

Section 16. Other information

This information is furnished without warranty, expressed or implied, except that is is accurate to the best of our knowledge.

Document information

Resideo Technologies, Inc., 1985 Douglas Drive North, Golden Valley, MN 55422. Customer care: 1-800-468-1502. www.resideo.com. © 2020 Resideo Technologies, Inc. All rights reserved. This product is manufactured by Resideo Technologies, Inc. and its affiliates.

60-0915—06   M.S. Rev. 05-20  |  Printed in United States

Download:Honeywell L4006,7,8; L6006,7,8 AquastatÆ Controllers Manual.pdf

Honeywell CT410B Thermostats Installation Instructions

above.

Resideo T410 line voltage electric heat thermostat with temperature setting knob
T410 electric heat thermostat.

Specifications

  • Models: T410A provides single-line break. T410B provides double-line break.
  • Temperature range: 40°F to 80°F (4°C to 27°C)
  • Electrical ratings: 60 Hz noninductive; 22A at 120-240 Vac; 19A at 277 Vac

Safety notices

WARNING — Electric shock hazard. This thermostat is a line voltage control (120 Volts to 277 Volts.) Do not install it if you are not completely familiar with house wiring. If handled improperly, there can be risk of a 120 Volt to 277 Volt electric shock hazard, which may cause serious injury or death.

Mercury notice. If this control is replacing a control that contains mercury in a sealed tube, do not place you old control in the trash. Dispose of properly.

Contact you local waste management authority for instruction regarding recycling and the proper disposal of a old control.

1. Preparation

  1. Proper installation of your Resideo thermostat will occur if you follow these instructions STEP-BY-STEP. It is recommended that as you read, understand and complete each step, you check it off with pencil or pen.
  2. Check thermostat suitability for your home system by reviewing the ratings listed on this page.
  3. Make certain that your heating system is working, especially if it has been inoperative for a length of time. If the system does not work, contact your local electrician for assistance.
  4. Carefully unpack your new thermostat. To avoid damage to the sensing element, do NOT remove the thermostat cover until wiring has been completed.
  5. Save packages of screws, instructions, receipt and proof-of-purchase.

2. Remove Old Thermostat

WARNING — Electric shock hazard. Begin by turning off power to the heating circuit at the main service panel.

  1. Remove cover of old thermostat. Cover normally snaps off when pulled firmly from the bottom. If it resists, check for a screw that locks the cover.
  2. Loosen screws holding thermostat base to outlet box and lift away.
  3. Disconnect wires from old thermostat. As you disconnect each wire, tape the end and label it with the letter of the terminal designation to make reconnection to new thermostat easier.
  4. Check the old insulation for cracks, nicks or fraying, and apply high quality plastic tape where necessary for adequate insulation.
  5. Retain the old thermostat for reference purposes and until your new thermostat is functioning smoothly.

3. Wire and Mount New Thermostat

  1. Connect wires to the thermostat as shown in the applicable wiring diagram.
  2. Remove thermostat cover by grasping the top and bottom ends with fingers, and pulling outward.
  3. Push the wires into the outlet box, and insert the thermostat into the box for mounting by pushing against top and bottom of the thermostat base.

Important: Do not press on setting knob.

  1. Secure the thermostat to the box with the two captive mounting screws provided.
  2. Replace thermostat cover.
  3. Set knob to desired room temperature.

Important: Rough handling or strong pressure can damage knob or sensing element, and change calibration.

Wiring diagrams for T410B double-line break and T410A single-line break thermostats, with legend notes and caution about aluminum conductors
Fig. 1. T410B (double-line break, left) and T410A (single-line break, right) wiring diagrams.
Diagram notes (text version)
  • Power supply. Provide disconnect means and overload protection as required.
  • Breaks on positive off.
  • Exposed unused leadwires to be properly insulated.
  • Thermally activated—breaks on temperature rise. Makes on temperature fall.

Caution: Special service CO/ALR solderless connectors must be used when connecting with aluminum conductors; otherwise, a fire hazard can result.

4. Check Out Thermostat

  1. Turn on the power to the heating system.
  2. Turn setting knob all the way clockwise; listen for clicking sound as switch makes contact. Electric heater should begin operation.
  3. Turn knob all the way counterclockwise; listen for clicking sound as switch breaks contact. Electric heater should shut off.

5. Setting Thermostat

  1. Begin with knob to the desired setting (typically 70°F [20°C] on the scale).
  2. If this setting is not satisfactory after at least two hours of operation, turn setting knob upscale to raise the temperature, or downscale to lower the temperature. Move knob only a degree each time.

6. Troubleshooting

Your Resideo thermostat requires little or no attention. Most problems can generally be traced to the following:

Table 1. Troubleshooting.

Symptom Checkout Action
No heat. Make sure power is on at main service panel. Turn the temperature setting knob fully clockwise. Heater should start to warm up within two minutes. If not, contact qualified electrician to check thermostat and heater.
Improper connections to thermostat. With power to circuit OFF, tighten all wiring connections. Repair any frayed or broken wires.
Other. Contact a qualified electrician for assistance.
Heater never turns off. Turn temperature setting knob fully counterclockwise. Heater should start to cool within minutes. If not, turn off power at the main service panel, and contact qualified electrician.
Thermostat setting and thermometer reading disagree. Thermostat affected by drafts or radiant heat. Contact electrician to change the location. The thermostat should be about 5 ft (1.5m) above the floor and on an inside wall.

1-Year Limited Warranty

Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one (1) years from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option).

If the product is defective,

  1. return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or
  2. call Resideo Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage which occurred while the product was in the possession of a consumer.

Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.

Document information

This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502. ©2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved. www.resideo.com

Resideo Inc., 1985 Douglas Drive North, Golden Valley, MN 55422

69-1562—02   M.S. Rev. 07-19  |  Printed in United States

Honeywell RTH7600 Series Installation Instructions

Honeywell Touchscreen Programmable Thermostat RTH7600 Series Installation Instructions

The Honeywell Touchscreen Programmable Thermostat RTH7600 Series Installation Instructions walk through eleven numbered steps, from shutting off power to matching the thermostat to your equipment. This page follows that document, 69-2206ES—05, which is linked below. It covers mounting, wiring for conventional and heat pump systems, the function settings the installer menu exposes, and the eight faults the manual itself lists. Schedule programming is not part of this booklet; the only reference to the Operating Manual is on the setup page for Smart Response Technology.

Download the Honeywell RTH7600 Series Installation Instructions (PDF)

Download the official Honeywell RTH7600 Series Installation Instructions (PDF)

Table of Contents

What These Installation Instructions Cover

The booklet is an installer document, not a homeowner guide. Its own contents page divides the work into two halves. The first half is the eleven numbered steps on pages 1 to 11. The second half is called Advanced Installation and runs from page 13 to page 26.

Advanced Installation breaks down like this:

  • Thermostat setup, pages 13 to 20. Entering setup options, the date, system type, changeover mode, temperature format, daylight saving time, the filter reminder, Smart Response Technology, and the clock format.
  • Wiring, pages 21 to 23. Alternate wiring for conventional systems on page 21, the heat pump connection procedure on page 22, and alternate wiring for heat pumps on page 23. The two alternate charts are for old thermostats whose terminal letters do not match the new one.
  • Troubleshooting, pages 24 and 25. Eight symptom-and-action entries.
  • Customer assistance, page 26.

Page numbers on this page are the ones printed on the sheet. The English section of the PDF file begins on file page 3, so printed page 13 is file page 15.

The booklet’s introduction page states the two principles behind the sequence: the thermostat “works with virtually all System Types” and “is preset for the most common system.”

Compatibility and Power Requirements

One sentence on page 11 decides whether the RTH7600 Series belongs on your wall at all. The thermostat “works on 24 volt or 750 mV systems. It will NOT work on 120/240 Volt systems.”

Page 11 also splits the work by system type, and the split is the reason some installations stop at step 11 while others continue into the advanced pages:

  • Single Stage Heat and Cool. The manual’s response is “Congratulations, you’re done!”
  • Multistage Heat and Cool, heat pump without backup heat, heat pump with backup heat, heat only, or cool only. These continue into the advanced pages, which the booklet describes as the step that matches the thermostat to the system type.

The same page defines a heat pump for readers who are unsure: “an air conditioner that provides cooling in the summer, and also runs in reverse in the winter to provide heating.” If the system type is still unclear, the manual directs the reader to the toll-free line at 1-800-468-1502.

What the terminal strip accepts

The conventional strip carries eight positions: R, RC, W, Y, G, C, W2 and Y2. The heat pump strip carries nine: R, RC, O/B, Y, G, C, L, E and Aux. The extra positions on each side are what separate a single-stage installation from a multistage one, and the function table later in this page is where those positions get declared.

Parts the Manual Names

The booklet references only what the installation actually touches:

  • Mounting screws and anchors, described in step 5 as “the included screws and anchors.”
  • Wire labels, described in step 3 as “the supplied wire labels.”
  • Two AA alkaline batteries, installed in step 7, which also has you remove a tab.
  • A small piece of wire, called for on the heat pump pages when the E and Aux terminals do not each have a conductor connected.

A screwdriver is required by the heat pump wiring steps, which say to “loosen screws, insert wires into hole, then tighten screws.” Two drill bits appear in step 5: 3/16-in. for drywall and 3/32-in. for plaster.

Step-by-Step Installation (Steps 1 to 11)

The eleven steps in the booklet run in one direction, with one branch at the end. Steps 1 to 9 are physical work at the wall. Steps 10 and 11 are done on the screen with the power back on.

Step 1: Turn off power to the heating and cooling system

The first page is a single instruction and a note. The instruction is to cut power to the heating and cooling system. The note is for readers who have already worked through the Quick Start Guide and only need to match the thermostat to a system type: that reader is sent straight to page 13.

Step 2: Remove the old thermostat

The old thermostat comes off, but its wallplate stays on the wall with the wires still attached. The page carries a warning about the old unit: if it holds a sealed tube containing mercury, the back cover of the booklet gives the disposal instructions.

Step 3: Label the wires with the supplied tags

Each conductor gets a tag as it is disconnected. The page adds one caution that matters more than it looks: “Wire color may not match labels.” Colour is not the identifier here. The tag is.

Step 4: Separate the wallplate from the new thermostat

The new wallplate arrives fitted to the back of the thermostat body and has to come off before it can be mounted. Step 4 is that separation and nothing else.

Step 5: Mount the new wallplate

The wallplate goes on with the included screws and anchors. The booklet prints two pilot-hole sizes on the same page:

  • 3/16-in. holes for drywall.
  • 3/32-in. holes for plaster.

Step 6: Connect the wires

The entire instruction is four words: “Simply match wire labels.” Each tag goes to the terminal of the same letter, and the wires are inserted into the holes and the screws tightened.

One exception sits under the drawing. Remove the metal jumper between R and Rc if both terminals will carry a wire. The full jumper rules are on page 21 and are covered under Wiring below.

Two routing notes appear on the page. A heat pump system sends the reader to pages 22 and 23. Terminal letters on the old thermostat that do not match send the reader to page 21.

Step 7: Install the batteries

Two AA alkaline batteries go into the back of the thermostat, and a tab is removed. The drawing labels the two locations as “Back of thermostat” and “Remove tab.”

Step 8: Install the thermostat onto the wallplate

The body pushes onto the mounted wallplate. Step 8 is that single action.

Step 9: Turn the power back on

Power returns to the heating and cooling system. Everything after this point happens on the screen.

Step 10: Set the time and date

The screen presents four values in a fixed order, with the arrow buttons changing the value and the NEXT button moving to the next one:

  1. Press the up or down arrow to set the month, then press NEXT.
  2. Press the arrow buttons to set the day, then press NEXT.
  3. Press the arrow buttons to set the year, then press DONE.
  4. Press the arrow buttons to set the time, then press DONE to save and exit.

Step 11: Match the thermostat to your system type

This step is a branch, not a task. A single-stage heat and cool system finishes here. Every other system type continues into Advanced Installation, where function 0170 declares what the thermostat is connected to.

If the date and time were already set on page 10, the advanced section notes that the reader can press NEXT through to function 0170 and go directly to the system type setting.

Wiring: Conventional and Heat Pump Terminals

Two drawings cover the terminals, one for each system family. In both cases the rule is the same as step 6: the tag on the wire and the letter on the terminal have to match.

Conventional terminal strip

Terminal Function
R Power side
RC Power side, jumpered to R by the metal jumper
W Heat
Y Cool
G Fan
C Common
Y2 Second cooling stage
W2 Second heating stage

The letters in the left column are printed on the thermostat. The function words beside them are added here to make the strip readable; the booklet prints the letters only.

Heat pump terminal strip

Terminal Function
R Power side
RC Power side, jumpered to R
O/B Changeover valve
Y Compressor
G Fan
C Common
L Service indicator
E Emergency heat
Aux Auxiliary heat

The same note applies to this table: the letters are the manual’s, the function words are added here. The heat pump page adds a fourth wiring step beyond matching, inserting and tightening: if E and Aux do not each have a wire connected, a small piece of wire joins them to each other. A fifth note says to push any excess wire back into the wall opening.

Alternate wiring when the old letters do not match

Older thermostats carry lettering this one does not. Page 21 has the conventional chart and page 23 has the heat pump chart. Both are read the same way: find the old label on the right, land the wire on the terminal at the left.

Conventional systems, page 21:

Old thermostat label Terminal on the RTH7600
Rc or R Rc
R, RH, 4, or V R
W, W1, or H W
Y, Y1, or M Y
G or F G
C, C1, X, or B C
Y2 Y2
W2 W2

Heat pump systems, page 23:

Old thermostat label Terminal on the RTH7600
Rc or R Rc
R, V, or VR R
O, H, or B O/B
Y, Y1, or M Y
G or F G
C, X, or B C
L or F L
E, X, or X2 E
Aux, W, W1, or W2 Aux

The R and Rc jumper

A metal jumper connects R and Rc on the terminal strip, and step 6 says to remove it if both terminals will carry a wire. Page 21 gives the three cases in full:

  • Both R and Rc wires present. Remove the metal jumper and connect both.
  • Old thermostat had R and RH wires. Remove the metal jumper, connect the R wire to the Rc terminal, and connect the RH wire to the R terminal.
  • No second power wire. Leave the jumper in place.

On a heat pump the instruction reverses: page 23 says to leave the metal jumper in place, connecting R and Rc.

Where the manual stops and calls a contractor

Three conditions on page 23 end the installation. Each one is a stop, not a caution:

  • An old thermostat with both V and VR wires.
  • An old thermostat with Y1, W1 and W2 wires.
  • Separate O and B wires, when another wire already occupies the C terminal. The manual’s instruction for the O and B case is to attach the B wire to the C terminal, and to stop only if C is already taken.

One further rule ties two terminals together: if the L terminal is used, the C terminal must have a wire, and the manual directs the reader to a contractor when there is no C wire.

Advanced Installation: Function Settings

Everything from page 13 onward is reached through the setup menu. The menu holds fifteen functions, numbered in hundreds, and the numbers are printed on the screen rather than in the booklet’s headings.

How to open the setup menu

  1. Press and release the left button.
  2. Press and hold the center button until the screen changes, which the manual puts at approximately five seconds.

Inside the menu, the arrow buttons change the value that is showing, NEXT moves to the next function number, and DONE saves and exits. The booklet notes that some functions may not appear at all, depending on selections already made. That is why a single-stage installation sees a shorter menu than a heat pump.

Function table

Function What it sets Options
0120 Year, first two digits 20 = year 20xx · 21 = year 21xx
0130 Year, last two digits 01 to 99
0140 Month 01 to 12
0150 Date 01 to 31
0170 System type 1 = heat and cool, gas, oil or electric with central air · 2 = heat pump without backup or auxiliary heat · 3 = heat only · 4 = heat only with fan · 5 = hot water heat only, no fan · 6 = cool only · 7 = heat pump with backup or auxiliary heat · 8 = two heat stages on W and W2, two cooling stages on Y and Y2 · 9 = two heat stages on W and W2, one cooling stage on Y · 10 = one heat stage on W, two cooling stages on Y and Y2
0180 Heating fan control 0 = gas or oil heat, system controls fan operation · 1 = electric heat, thermostat controls fan operation
0190 Heat pump changeover valve 0 = cooling changeover valve, for an O wire on O/B · 1 = heating changeover valve, for a B wire on O/B
0240 Heating cycle rate 5 = gas or oil furnace under 90% efficiency · 9 = electric furnace · 3 = hot water system or gas furnace over 90% efficiency · 1 = gas or oil steam or gravity system
0270 Emergency heat cycle rate, heat pumps only 9 = electric furnace · 5 = gas or oil furnace under 90% efficiency · 3 = hot water system or gas furnace over 90% efficiency · 1 = gas or oil steam or gravity system
0300 Manual or auto changeover 0 = manual, Heat, Cool and Off · 1 = automatic, Heat, Cool, Auto and Off, which turns on heat or cool from room temperature and keeps a minimum 3°F difference between the heat and cool settings
0320 Temperature format 0 = Fahrenheit · 1 = Celsius
0330 Daylight saving time 0 = off, no adjustment · 1 = on, for areas that do not use the 2007 DST calendar · 2 = on, for areas that use the 2007 DST calendar
0500 Furnace filter change reminder 0 = off · 1 = 10-day run time, about 1 month · 2 = 30 days, about 3 months · 3 = 60 days, about 6 months · 4 = 90 days, about 9 months · 5 = 120 days, about 1 year · 6 = 365 days, about 3 years
0530 Smart Response Technology 1 = on · 0 = off
0640 Clock format 12 = 12-hour clock · 24 = 24-hour clock

The booklet defers one function to another document: function 0530 refers the reader to the Operating Manual for an explanation of Smart Response Technology. The setup pages end with DONE to save and exit.

Troubleshooting

The manual’s troubleshooting pages are a two-column list of eight entries, running across pages 24 and 25. Symptom wording and the action column below follow that list. The cause column is added here, because the manual prints actions without stating a cause.

Symptom Likely cause What the manual says to do
Display is blank The batteries are missing or not seated Make sure fresh AA alkaline batteries are properly installed (see page 7).
Cannot change system setting to Cool The system type does not include cooling Check Function 0170: System Type to make sure it is set to match your heating and cooling equipment (see page 16).
Fan does not turn on when heat is required The fan control setting does not match the heating equipment Check Function 0180: Heating Fan Control to make sure it is set to match your heating equipment (see page 17).
Heating system is running in cool mode The system type is declared incorrectly Check Function 0170: System Type to make sure it is set to match your heating and cooling equipment (see page 16).
Red light is on The thermostat is in Emergency Heat mode, or it is not and something else is wrong If thermostat is in Emergency Heat mode the red light is normal. It shows that the thermostat is in emergency heat mode. If thermostat is not in Emergency Heat mode, contact a qualified service contractor for repair.
Heating or cooling system does not respond The system switch position, the setpoint, or power at the equipment Press SYSTEM to set system to Heat. Make sure the temperature is set higher than the Inside temperature. Press SYSTEM to set system to Cool. Make sure the temperature is set lower than the Inside temperature. Check circuit breaker and reset if necessary. Make sure power switch at heating & cooling system is on. Make sure furnace door is closed securely. Wait 5 minutes for the system to respond.
“Wait” appears on the screen Compressor protection is holding the compressor back Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor.
Heat pump issues cool air in heat mode, or warm air in cool mode The changeover valve setting is inverted Check Function 0190: Heat Pump Changeover Valve to make sure it is properly configured for your system (see page 17).

Four of the eight entries route back to a function number, which is the pattern worth noticing: 0170 appears twice, 0180 once, and 0190 once. After mounting and wiring, most faults on this thermostat are settings that were left on the wrong value rather than failed parts.

Page 26 of the booklet gives the escalation path. Assistance is at http://yourhome.honeywell.com or on the toll-free line, 1-800-468-1502. The same number appears on the inside front cover, with the note to call before returning the thermostat to the store, and again on the step 6 page for wiring assistance.

Specifications

  • Model line: RTH7600 Series, touchscreen programmable thermostat.
  • Document: 69-2206ES—05, revision 04-11, printed in the U.S.A., © 2011 Honeywell International Inc.
  • Power source: two AA alkaline batteries, installed at step 7.
  • System voltage: 24 volt or 750 mV. Not for 120/240 volt systems.
  • Conventional terminals: R, RC, W, Y, G, C, Y2, W2.
  • Heat pump terminals: R, RC, O/B, Y, G, C, L, E, Aux.
  • System types: ten options at function 0170, covering single-stage heat and cool, heat pump with and without backup heat, heat only, hot water heat only, cool only, and three multistage combinations.
  • Changeover: manual or automatic, set at function 0300. Automatic mode keeps a minimum 3°F between the heat and cool settings.
  • Compressor protection: a five-minute wait is printed in the troubleshooting list and applies to the “Wait” message.
  • Filter reminder intervals: 10, 30, 60, 90, 120 or 365 days of run time, set at function 0500.
  • Warranty: one year from the date of purchase, excluding the battery.
  • Operating caution: to avoid possible compressor damage, do not run the air conditioner when the outside temperature drops below 50°F (10°C).

Frequently Asked Questions

Where can I get the RTH7600 Series installation instructions as a PDF?

The download link at the top and bottom of this page opens the manufacturer PDF for this document. It holds the eleven numbered steps, the terminal drawings for conventional and heat pump systems, the alternate wiring charts, and the fifteen-function setup table.

What batteries does the RTH7600 Series take?

Two AA alkaline batteries, installed in step 7 on the back of the thermostat, and the step also has you remove a tab. The troubleshooting list sends a blank display back to that same page.

Does the RTH7600 need a C wire?

There is a C position on the strip, and step 7 installs two AA alkaline batteries as the supply the booklet calls for. On a heat pump the C terminal matters in one case. If the L terminal is used, the manual says the C terminal must carry a wire. It sends you to a contractor when there is no C wire.

Why will the thermostat not switch to Cool?

Function 0170, System Type, is probably set to a type that has no cooling. The manual’s own answer is to check that function against your equipment. The same function is the manual’s answer when the heating system runs in cool mode.

What does a Wait message on the screen mean?

Compressor protection is engaged. The manual says to wait 5 minutes for the system to restart safely, without damage to the compressor. Nothing needs resetting.

How do I open the installer setup menu?

Press and release the left button, then press and hold the center button until the screen changes, which takes about five seconds. The arrows change a value, NEXT moves to the next function number, and DONE saves and exits.

Can the RTH7600 Series control a two-stage system?

Yes. The strip carries W2 and Y2, and function 0170 offers three multistage options: two heat stages with two cooling stages, two heat stages with one cooling stage, and one heat stage with two cooling stages. A single-stage heat and cool system is the one type that finishes at step 11.

When should I stop and call a contractor instead?

The heat pump wiring page names three stops. They are an old thermostat with both V and VR wires, one with Y1, W1 and W2 wires, and separate O and B wires where the C terminal is already occupied. Use of the L terminal without a C wire is a fourth case the same page sends to a contractor.

Honeywell 7 day programmable thermostat RTH7600D Operating Manual

Honeywell 7 day programmable thermostat RTH7600D Operating Manual

This page is a plain walk-through of the Honeywell 7 day programmable thermostat RTH7600D Operating Manual (document 69-2207EF). The RTH7600D is Honeywell’s touchscreen 7-day model, so the steps here differ from the button-based thermostats you may have used before. Every point is taken from the official manual and labeled with its section so you can check it. The operating manual PDF is linked at the top; read it alongside your unit, especially before you touch any wiring.

Download the official Honeywell RTH7600D Operating Manual (PDF)

Table of Contents

What the RTH7600D Is

The RTH7600D is a touchscreen, 7-day programmable thermostat for a central heating and cooling system. Honeywell’s “About your new thermostat” section lists its core capabilities:

  • A large touchscreen display with a backlight, readable even in the dark.
  • Daily program schedules that balance comfort and energy savings.
  • One-touch temperature control that overrides the schedule at any time.
  • Precise control that holds the room within 1°F of the temperature you set.
  • A furnace filter change/check reminder.

It also offers Smart Response learning, Auto Changeover between heat and cool, and a compressor-protection delay. The unit is a 1-heat / 1-cool thermostat, so it is not meant for multistage systems.

The Controls and the Screen

The RTH7600D has a small set of physical buttons and on-screen softkeys (Quick reference to controls):

  • Arrow keys. Adjust the temperature or make selections from the on-screen menus.
  • CLOCK. Open the clock (time and day) setting, and the filter reminder.
  • SCHEDULE. Open the program schedule.
  • SYSTEM & FAN. Switch to the System or Fan menu, then press DONE to save or GO BACK to cancel.

The home screen shows the day, the time, the set temperature, and the current room temperature, plus the active System and Fan settings. Temporary messages include Cool On, Heat On, Recovery (Smart Response is working early) and Wait (compressor protection is delaying the restart).

First-Time Setup

After you mount the thermostat and restore power, Honeywell says it is essentially ready to run: it ships pre-programmed. The only required step is to set the time and day. The defaults it lists are:

  • Fan: Auto.
  • System: Heat.
  • Program: energy-saving levels assuming you wake at 6 AM, leave at 8 AM, return at 6 PM and sleep at 10 PM.

Adjust any of these to your own routine. The manual pre-set schedule is Wake 6:00 AM 70°, Leave 8:00 AM 62°, Return 6:00 PM 70° and Sleep 10:00 PM 62° for heating (with separate cooling setpoints).

Setting the Clock, Fan and System

  • Clock. Press CLOCK, then press the up or down arrow to set the time; press and hold an arrow to move faster. Press DONE to save (GO BACK exits without saving). The clock keeps date and time and updates for daylight saving on its own.
  • Fan. Press SYSTEM & FAN, then FAN, and choose On (fan runs continuously) or Auto (fan runs only during heating or cooling). Press DONE.
  • System. Press SYSTEM & FAN, then SYSTEM, and choose Heat, Cool or Auto. In Auto the thermostat decides whether to heat or cool to reach the setpoint. Press DONE.

Programming the Daily Schedule

You can set four periods each day (Wake, Leave, Return and Sleep) with different temperatures, and different settings for weekdays and weekends. Press SCHEDULE, then for each period set the time with the arrow keys, confirm, and set the temperature. The manual notes you can program the weekday schedule first, then the weekend days. Set the System to Heat or Cool first, because heating and cooling are programmed separately.

Around-the-program economy is the goal: lower the heat and raise the cooling while you are away or asleep, and bring them back for morning and evening.

Overriding the Schedule

For a quick change, press an arrow key. The screen shows Temporary, and the new temperature holds only until the next scheduled period, then the program resumes. To override all periods, use the Hold option; to clear the hold and return to the schedule, press Cancel (or RUN to resume, as the on-screen prompt shows).

Auto Changeover, Smart Response and Compressor Protection

  • Auto Changeover. With System set to Auto, the thermostat picks heating or cooling to reach the set temperature, so you rarely change modes by hand. Honeywell cautions against running cooling when the outdoor temperature is below 50°F (10°C).
  • Smart Response. The thermostat learns how long your system takes to reach a setpoint and starts early so the temperature is met on time; Recovery appears while it is running ahead of a period.
  • Compressor Protection. After a shutdown the thermostat waits a few minutes before restarting the compressor to avoid damage; Wait is shown during this delay.

In Case of Difficulty

This is the manual’s own troubleshooting guidance (In case of difficulty). For a heating or cooling system that does not respond, it lists these checks:

  • Press SYSTEM and set it to Heat, then make sure the set temperature is higher than the indoor temperature; or set it to Cool with the temperature lower than indoor.
  • Check the circuit breaker and reset it if needed.
  • Make sure the power switch at the heating and cooling system is on.
  • Make sure the furnace door is closed securely.
  • If Wait is shown, the compressor protection timer is active; wait about 5 minutes for the system to restart.

Batteries and Wiring

The RTH7600D runs on two fresh AA alkaline batteries. If your thermostat was wired to run on AC power, batteries are optional and act as backup. Install fresh batteries as soon as LO BATT starts flashing; the warning appears about 30 days before the batteries die, and Honeywell recommends changing them once a year or before a trip longer than a month. Note the disposal guidance: the unit contains a lithium battery that may contain perchlorate material.

This operating manual covers use, not installation. Wiring, terminal layout and system-type setup are in the separate RTH7600 Installation Instructions (69-2206), which Honeywell ships with the thermostat; follow that document and switch off power before touching any wire.

Specifications

  • Type: 7-day programmable, touchscreen, 1 heat / 1 cool.
  • Display: Large touchscreen with backlight.
  • Program: Four periods per day (Wake, Leave, Return, Sleep); weekday and weekend settings.
  • Temperature control: Holds within 1°F of the setpoint.
  • System modes: Heat, Cool, Auto.
  • Fan modes: On, Auto.
  • Power: Two AA alkaline batteries (backup if wired for AC power).
  • Extras: Smart Response, Auto Changeover, compressor protection, filter reminder.
  • Warranty: 1-year limited (excludes battery); Honeywell Customer Care 1-800-468-1502.
  • Not for: Multistage systems.

FAQ

Is the RTH7600D a 7-day programmable thermostat?

Yes. It is a 7-day programmable model with four time periods a day (Wake, Leave, Return, Sleep) and separate weekday and weekend settings.

How do I set the clock and day?

Press CLOCK, use the up or down arrow to set the time, then set the day, and press DONE. The clock holds date and time and adjusts for daylight saving on its own.

Why does the screen show “Wait”?

That is compressor protection. The thermostat delays the compressor by a few minutes after a shutdown to prevent damage, then starts normally.

What batteries does the RTH7600D use?

Two fresh AA alkaline batteries. If the unit is wired for AC power, the batteries serve as backup. Replace them when LO BATT flashes.

What is the “Recovery” message?

Recovery means Smart Response is running the system ahead of a scheduled period so the temperature is met at the time you set.

Where do I find wiring for this thermostat?

The operating manual does not include wiring. See the separate RTH7600 Installation Instructions (69-2206) that ships with the unit, and always switch off power before handling wires.

 

Honeywell Digital Thermostat T6811DP08 Instruction Manual

Honeywell Digital Thermostat T6811DP08 Instruction Manual

The Honeywell Digital Thermostat T6811DP08 User Manual helps technicians install, wire, configure and troubleshoot this non-programmable thermostat for two-pipe fan coil systems. This guide covers the installation document, terminal designations, operating controls, installer settings, test procedures and common faults. It also explains the electrical safety precautions required before working on this 110 VAC thermostat.

Quick Facts and Specifications

The T6811DP08 is a digital fan coil thermostat designed for manual heating and cooling selection, ventilation and three-speed fan control. It is relevant to building maintenance teams working with fan coil units in hotels, apartments, offices and similar facilities.

Specification

T6811DP08 Details

Model

Honeywell T6811DP08

Supply voltage

110 (+20%, −10%) VAC

Supply frequency

50/60 Hz

System application

Two-pipe fan coil

Control modes

Heat, Cool and Vent

System selection

Manual heating/cooling changeover

Fan control

Three speeds: Low, Medium and High

Temperature setting range

10–32°C

Temperature control accuracy

±1°C at 21°C

Electrical load rating

4(2) A

Protection rating

IP20

Operating temperature

−18 to 49°C

Installation

Wall-mounted

Mounting boxes

86 × 86 mm or 2 × 4 inch junction box

Programming

Non-programmable; no seven-day schedule

Important: The T6811DP08 is a line voltage thermostat, not a conventional 24 VAC low-voltage thermostat. Do not assume that wiring instructions for other Honeywell models apply to this unit.

Where to Download the Official Manual PDF

The principal installation document for this thermostat family is identified as 62-0325ES-01. It covers the T6811DP08 and T6812DP08 models.

Installation Instructions: 62-0325ES-01

This document is the primary reference for installation and servicing. It includes display indicators, terminal designations, wiring diagrams for two-wire and three-wire valve actuators, wall mounting, Installer Setup, Installer Test, normal operation and troubleshooting.

View the T6811DP08/T6812DP08 Installation Instructions PDF. This is an archived copy of a Honeywell-branded document, rather than a verified current manufacturer-hosted download.

Understanding the Display

Indicator

Meaning

Temperature

Displays room temperature or the value selected by the display configuration.

Setpoint

Identifies the selected temperature setting.

Current Mode

Shows the active mode: Heat, Cool or Vent.

Heating or Cooling Demand

Indicates that the thermostat is calling for heating or cooling.

Keypad Lock

Indicates that keypad lockout is active.

Setup

Indicates Installer Setup mode.

Test

Indicates Installer Test mode.

Setup/Test Number

Identifies the configuration item or test function displayed.

The display's appearance can vary according to the active mode and installer configuration.

Button and Switch Functions

  • UP: In normal Heat or Cool operation, increases the selected temperature setpoint. It also changes values in Installer Setup and Installer Test modes.
  • DOWN: Decreases the temperature setpoint or changes the value of the selected configuration item.
  • MODE: Cycles through Heat, Cool and Vent.
  • POWER switch: Turns the thermostat on or off.
  • FAN switch: Selects Low, Medium or High fan speed.

In Vent mode, the fan operates without a heating or cooling demand from the thermostat. If a button appears unresponsive, check whether the thermostat is switched off, keypad lockout is active or Vent mode has been selected.

Terminal Designations and Wiring Diagram

Correct terminal identification is essential when installing or replacing a Honeywell T6811DP08.

Terminal

Function

Application

L

Line voltage power

Incoming live supply

Ch/Cc

Heating close / Cooling close

Valve actuator control

W/Y

Heating open / Cooling open

Valve actuator control

N

Neutral supply connection

Electrical supply common

Gl

Low-speed fan

Fan motor low-speed input

Gm

Medium-speed fan

Fan motor medium-speed input

Gh

High-speed fan

Fan motor high-speed input

Wiring terminology: The original document's extracted terminal table describes N as a line-voltage ground connection. Do not interpret this as permission to connect neutral and protective earth together. Confirm the actual supply and protective-earth requirements against applicable electrical regulations and verified manufacturer documentation before wiring.

Two-Wire Valve Actuator

The installation document includes a typical ON/OFF control arrangement for a two-pipe heating/cooling system with a two-wire valve actuator. The actuator wiring arrangement depends on its electrical design. Follow the manufacturer's diagram to identify the correct actuator connections and the terminals used for opening and closing. Do not infer a complete actuator circuit from terminal names alone.

Three-Wire Valve Actuator

The manual also illustrates a typical arrangement for a three-wire valve actuator. A three-wire actuator may use different connections for its control functions than a two-wire ON/OFF actuator. The exact connections depend on the actuator design and must match the wiring diagram supplied for that device.

Before connecting the valve, establish:

  • Whether the actuator is designed for the available supply voltage.
  • Which conductors provide the required control functions.
  • Which thermostat terminals the verified diagram specifies.
  • Whether the existing system is configured for heating or cooling.

Do not interchange two-wire and three-wire actuator wiring arrangements without confirming compatibility.

DANGER: 110 VAC LINE VOLTAGE — ELECTRIC SHOCK HAZARD

The T6811DP08 operates from a 110 VAC nominal supply. Contact with live conductors can cause serious injury or death.

  • Disconnect the electrical supply before installation, wiring, inspection or maintenance.
  • Verify that the circuit is de-energised using an appropriate test instrument.
  • Do not treat this thermostat as a 24 VAC low-voltage device.
  • Have installation and electrical troubleshooting performed by a qualified electrician or HVAC technician.
  • Restore power only after all connections, covers and mounting screws have been checked.

Wiring Diagram Reference

Consult the wiring diagrams in document 62-0325ES-01 for the illustrated two-wire and three-wire actuator arrangements. Never use a generic fan coil wiring diagram as a substitute for the correct diagram for the installed valve, fan motor and supply arrangement.

Installation Steps

Step 1: Mount the Back Cover

Isolate the electrical supply. Pull the existing conductors through the wiring opening and position the back cover over the wall junction box. The thermostat is intended for installation on an 86 × 86 mm or 2 × 4 inch junction box, subject to confirmation of the actual mounting arrangement.

Step 2: Secure the Back Cover

Insert the mounting screws and tighten them securely. Check that the back cover sits correctly against the mounting surface without pinching or damaging conductors.

Step 3: Connect the Wires

Loosen the relevant screw terminals. Insert each conductor into its designated terminal and tighten the terminal screw. Verify every connection against the correct wiring diagram before proceeding.

Step 4: Fit the Thermostat Body

Align the top of the thermostat with the back cover. Push the body down into position as shown in the installation instructions. Check that the housing is properly seated.

Step 5: Tighten the Locking Screw

Insert the locking screw into the hole at the bottom of the thermostat and tighten it. Before restoring power, check the wiring, enclosure, terminal tightness and mechanical fit.

After installation, confirm normal display operation, fan-speed selection, mode selection and heating or cooling response.

Installer Setup Menu Walkthrough

Installer Setup changes how the thermostat operates. Incorrect settings can prevent the device from controlling the intended HVAC system correctly.

Entering Installer Setup

  1. Ensure the thermostat is powered and accessible.
  2. Press and hold UP and MODE simultaneously for three seconds.
  3. Confirm that the display indicates Installer Setup.
  4. Press UP or DOWN to change the selected setting.
  5. Press MODE to advance to the next function.
  6. Press and hold UP and MODE simultaneously for three seconds to exit and save the settings.

Record the original settings before making changes, particularly in occupied buildings where the thermostat is part of a larger maintenance system.

Installer Setup Number Reference Table

The following reference is based on the settings listed in document 62-0325ES-01. Verify the values against a legible original copy before relying on them for commissioning.

Number

Name

Available Values

Default

1

System Type

0: Heat only; 1: Cool only; 2: Two-pipe, manual heating/cooling

2

9

Temperature Scale

°F or °C; verify displayed option coding against the original table

°C

13

CPH Value for Heat

1–12

4

14

CPH Value for Cool

1–6

3

18

Display Temperature Adjustment

−2, −1.5, −1, −0.5, 0, +0.5, +1, +1.5, +2°C, with corresponding Fahrenheit values

0°C

19

Temperature Display Mode

0: Room temperature; 1: Setpoint

0

20

Heating Range Stops

10–32°C; 50–90°F

32°C / 90°F

21

Cooling Range Stops

10–32°C; 50–90°F

10°C / 50°F

22

Keypad Lockout

0: All keys available; 1: All keys locked out

0

  • System Type 1 selects a cooling-only configuration; System Type 0 selects heating-only.
  • System Type 2 is the listed default for two-pipe manual heating/cooling operation.
  • CPH means cycles per hour. Change these parameters only when the application and manufacturer guidance justify doing so.
  • Setting 18 adjusts the displayed temperature offset. It should not be used to conceal an actual HVAC control or sensor fault.
  • Settings 20 and 21 establish heating and cooling setpoint limits.
  • Setting 22 controls keypad lockout.

The original table's temperature-scale option coding should be checked against a legible copy of the relevant document before reproducing it as an exact menu-value sequence: [VERIFY].

Installer Test Mode

Installer Test mode helps a qualified technician check heating and cooling outputs independently of normal user operation.

Entering Installer Test

  1. Press and hold UP and DOWN simultaneously for three seconds.
  2. Confirm that Installer Test mode is displayed.
  3. Use UP or DOWN to change the selected test value.
  4. Press MODE to advance to the next test function.
  5. Exit by pressing and holding UP and MODE simultaneously for three seconds.

Number

Function

Available Values

10

Heating Test

0: Heat Off; 1: Heat On

30

Cooling Test

0: Cool Off; 1: Cool On

70

Software Information

Press UP to view items 71–73

71

Software Version

Major version

72

Software Version

Minor version

73

Identification Code

Software identification value

Items 71–73 display information associated with the installed thermostat. Read the actual values from the device; do not assume them from another unit.

During output tests, verify the system's response and follow the site's electrical safety procedures. Do not force a valve or fan output if doing so could damage connected equipment.

Daily Operation

Switching the Thermostat On or Off

Use the physical POWER switch to turn the thermostat on or off. After switching it on, check the display and confirm that the selected mode matches the intended system operation.

Selecting Fan Speed

Move the FAN switch to the required setting:

  • Low: Low fan speed.
  • Medium: Medium fan speed.
  • High: High fan speed.

The selected speed determines the fan output used during operation.

Selecting Heat, Cool or Vent

Press MODE to select the required operating mode.

  • Heat: The thermostat can call for heating when the room temperature and setpoint require it.
  • Cool: The thermostat can call for cooling when the room temperature and setpoint require it.
  • Vent: Only the fan operates; the thermostat does not call for heating or cooling in this mode.

In a two-pipe fan coil system, heating or cooling availability also depends on the water supplied to the coil and the building's seasonal changeover arrangement.

Adjusting the Temperature

In Heat or Cool mode, press UP or DOWN to select the desired temperature. The available setting range is 10–32°C, subject to configured heating or cooling limits.

This is a non-programmable thermostat. It does not support a seven-day schedule or programmable daily heating and cooling periods.

Troubleshooting

Use the following checks before replacing the thermostat. For line-voltage testing or suspected wiring faults, consult a qualified technician.

Symptom

Possible Cause

Recommended Action

Heating does not start

Incorrect mode or setpoint

Select Heat and set the target temperature above room temperature.

Cooling does not start

Incorrect mode or setpoint

Select Cool and set the target temperature below room temperature.

Heating or cooling demand is absent

No active call for heating or cooling

Check the displayed mode, room temperature and setpoint.

Output is indicated, but the room does not change temperature

Valve, water supply, fan coil or building-system fault

Check the valve actuator, fan operation and availability of heating or chilled water.

Fan does not operate

Incorrect fan setting, supply issue or fan motor fault

Check the FAN switch and have the electrical supply and motor inspected safely.

Fan runs, but heating or cooling is ineffective

Valve or coil issue, unsuitable water temperature or restricted airflow

Inspect the fan coil and associated HVAC system.

MODE button does not respond

Thermostat is off or keypad is locked

Check the POWER switch and keypad lockout setting.

UP or DOWN does not respond

Keypad lockout, Vent mode or thermostat switched off

Check the operating mode, POWER switch and Setting 22.

Temperature display seems inaccurate

Display offset or sensor-related issue

Check Setting 18 and verify room temperature independently.

Thermostat appears completely dead

Supply interruption, wiring fault or device failure

Have a qualified technician verify the supply and connections.

For heating or cooling calls, the installation document recommends allowing approximately five minutes for the system to respond after checking the mode and setpoint.

Do not assume that a displayed heating or cooling demand proves the valve, fan motor or wider building system is functioning correctly.

Maintenance, Keypad Lock and Temperature Display Adjustment

Routine Maintenance

Keep the thermostat housing clean and free from dust. Use a soft, dry cloth and avoid spraying liquid directly onto the device. Do not open the housing or clean the terminal block while the circuit is energised.

During planned maintenance, check the mounting, enclosure, visible wiring condition and operation of the display and controls.

Keypad Lockout

Keypad lockout is controlled by Installer Setup Setting 22.

  • 0: All keys available.
  • 1: All keys locked out.

If the buttons appear to be disabled, have an authorised technician check Setting 22. Restore the intended setting after maintenance.

Temperature Display Adjustment

Setting 18 adjusts the displayed temperature by an offset from −2°C to +2°C. Setting 19 selects whether the display shows room temperature or the setpoint.

Before changing either setting, compare the display with a suitable independent thermometer and record the original configuration. If the temperature difference persists, investigate the installation and wider control system rather than relying solely on an offset adjustment.

Alternatives and Replacements

Honeywell T6812DP08

The T6812DP08 is the 220 VAC counterpart identified in the T6811DP08/T6812DP08 installation document. It may be relevant where the building's supply voltage differs from the T6811DP08 requirement.

However, the models must not be treated as interchangeable without checking the actual supply, load requirements, wiring arrangement and full model identification.

Upgrading to a Programmable Thermostat

A programmable thermostat may be suitable where building operators need scheduled temperature changes, occupancy-based operation or integration with a broader building-control strategy.

The replacement must be explicitly compatible with the installation's electrical supply, fan coil configuration, valve actuator and fan-speed outputs. Do not replace the T6811DP08 with a generic 24 VAC thermostat without confirming compatibility. A device designed for low-voltage control may not be suitable for a 110 VAC installation.

For hotels, hospitals and commercial buildings, have the proposed replacement approved by the responsible HVAC engineer or controls contractor.

honeywell programmable thermostat Owner’s Manual

Read online honeywell programmable thermostat Owner’s Manual pdf with better navigation. Printable and downloadable honeywell programmable thermostat user guide pdf

https://www.honeywellmanual.com/pdf/33-00102ES.pdf

1-Week Programmable Thermostat Owner’s Manual
Model: RTH2300, RTH221
English, Spanish


https://www.honeywellmanual.com/pdf/69-2060EFS.pdf

1-Week Programmable Thermostat Installation Manual
Model: RTH111,RTH221
English,French,Spanish


https://www.honeywellmanual.com/pdf/69-2448ES.pdf

1-Week Programmable Thermostat Installation Manual
Model: RTH2300,RTH221
English,Spanish


Note: For opening this honeywell programmable thermostat manual, your computer need Adobe Reader. You can get the Adobe Reader for free by going here https://get.adobe.com/reader/