Author Archives: Therm

How to Reset a Honeywell Thermostat (By Model)

How to Reset a Honeywell Thermostat (By Model)

If your Honeywell thermostat is acting up, a reset may help—but you do not always need to restore it to factory settings.

A thermostat that has lost its Wi-Fi connection needs a different fix from one that keeps changing the temperature. Before resetting anything, check the model number and decide what you want to clear.

Which Reset Should You Use?

What is happening? What to try
The thermostat is not responding Check the display, batteries if applicable, and power supply first.
Wi-Fi stopped working Open the Wi-Fi or network settings and reconnect.
The temperature changes at certain times Check the programmed schedule and Hold settings.
You want to erase saved settings Find the factory reset procedure for your exact model.
The screen is blank Check the power source before attempting a reset.

Honeywell thermostats do not all use the same reset procedure. The steps below cover several common Honeywell Home models. If your model is not listed, use the official instructions linked at the end of this guide.


How to Factory Reset a Honeywell Thermostat

A factory reset returns the thermostat to its default settings. Depending on the model, this can remove programmed schedules, Wi-Fi settings, preferences, and other configuration information.

Before proceeding: If you do not know how your heating and cooling system was configured, avoid a factory reset until you have checked the installation instructions. Some systems require specific installer settings to operate correctly.

Honeywell Home T9

These steps apply to the T9 models RCHT9510WF and RCHT9610WF.

  1. Press the Menu icon on the thermostat.
  2. Scroll to Advanced Setup and select it.
  3. Select Reset.
  4. Choose Factory Reset.
  5. Follow any remaining prompts on the screen.

Once the reset is complete, you may need to configure the thermostat again.

Honeywell Home T5, T5+ and T6

Honeywell lists specific T5, T5+ and T6 models under its reset instructions, including RCHT8610WF, RCHT8612WF, TH6320WF2 and TH6220WF2.

  1. Press and hold Menu.
  2. Press > until you see Reset, and then select it.
  3. Press > until you see Factory Reset, and then select it.
  4. Congratulations! You’ve reset your device! You can now configure your device for its new settings, either using the Resideo App, or on the thermostat screen itself.

Check the model number before following these steps. Similar product names do not guarantee identical controls or menus.

Honeywell Smart Wi-Fi 9000

For the listed RTH9580WF, RTH9585WF and TH9320WF models, Honeywell’s instructions give this path:

  1. Press Menu.
  2. Press Restore Factory Defaults.
  3. Select Yes to confirm.
  4. Congratulations! You’ve reset your device!

Do not use this menu path for another thermostat simply because its screen looks similar.

How to Reset Honeywell Thermostat Wi-Fi

If your thermostat still controls the temperature but cannot connect to your home network, try the Wi-Fi settings before performing a factory reset.

The exact procedure depends on the model.

T9: Change the Wi-Fi Network

For the Honeywell Home T9 models RCHT9510WF and RCHT9610WF:

  1. Press Menu.
  2. Select Wi-Fi.
  3. Choose Change Network.
  4. Select your network and enter the password.

This procedure is useful if you have changed your router or Wi-Fi password. If the network does not appear, check that the router is working and that the network meets the thermostat’s requirements.

Other Honeywell models may have a separate Wi-Fi reset or setup option. Follow the instructions for your specific model rather than assuming the T9 procedure applies.


How to Reset the Temperature Schedule

If the thermostat keeps changing the temperature when you do not expect it to, check the schedule first. A programmed period may be overriding the temperature you selected manually.

You may not need a factory reset.

For the Honeywell Home T9 models RCHT9510WF and RCHT9610WF, Honeywell provides this schedule-reset procedure:

  1. Press Menu.
  2. Open Advanced Setup.
  3. Select Reset.
  4. Choose Schedule Reset.

A schedule reset is different from a factory reset. It targets the programmed schedule rather than restoring every thermostat setting.

Before clearing the schedule, check whether the thermostat is following a programmed period or whether a Hold setting is active. If you only want a different temperature for a short time, changing the current setting may be enough.


What If the Thermostat Still Does Not Work?

Resetting will not solve every thermostat problem. If the issue remains, check the symptom before trying another reset.

The display is blank. If your model uses batteries, check whether they need replacing. For a hardwired thermostat, a blank display may indicate a power problem involving the HVAC system or thermostat wiring. Do not handle wiring unless you know how to work safely with the equipment.

The thermostat will not connect to Wi-Fi. Confirm that your router is online and that you are entering the correct network password. If you recently changed network equipment, use the thermostat’s documented network setup procedure.

The temperature is wrong or keeps changing. Check the schedule, Hold settings and selected operating mode. A reset may not be necessary if a programmed setting is responsible.

The heating or cooling system will not run. Check the selected mode and setpoint. If the thermostat has power but the HVAC equipment does not respond, the cause may be outside the thermostat. A reset cannot repair a failed component or incorrect wiring.

If the thermostat still behaves incorrectly after the appropriate reset, consult the model-specific troubleshooting section in its manual or contact a qualified HVAC technician.

Where to Find the Correct Reset Instructions

​For the correct reset instructions, it’s best to download the user manual for your specific model.”


Frequently Asked Questions

Does resetting a Honeywell thermostat erase the schedule?

It depends on the reset type. A schedule reset is intended to clear the programmed schedule. A factory reset may remove additional settings, depending on the model.

How do I reset a Honeywell thermostat without a reset button?

Many Honeywell thermostats use on-screen menus or button combinations instead of a dedicated reset button. The correct method depends on the model, so check its instructions before trying a button sequence.

Will a factory reset fix a Honeywell thermostat that is not connecting to Wi-Fi?

Not necessarily. If the problem is a changed network name or password, reconnecting through the Wi-Fi settings may be sufficient. Try the model’s documented network procedure before erasing all settings.

What should I do if none of the reset methods work?

Confirm the model number and check the troubleshooting instructions in its manual. If the thermostat has a blank display, the HVAC system does not respond, or the controls still fail, the issue may require further electrical or equipment diagnosis rather than another reset.

Need the instructions for your exact thermostat? Find the model number first, then use the matching Honeywell manual. The correct procedure can vary even between thermostats in the same product family.

Venstar VOYAGER T4900 Owner's Manual

Venstar VOYAGER T4900 Owner’s Manual

This guide covers the Venstar VOYAGER T4900 Owner’s Manual (P/N 88-1012, Rev. 5), the 60-page document for Venstar’s multi-stage Voyager thermostat. The T4900 is not a simple heat-and-cool dial: it stages heating and cooling, adds humidity control, and can take an optional wireless module. The steps below follow the manual and name its own controls and menus, and the PDF is linked here. Confirm anything that looks unfamiliar against the printed guide before you energize the system.

Skip to PDF content

Table of Contents

What the T4900 Is

The Voyager T4900 is a 24 VAC digital thermostat built around four buttons plus a scrolling backlit LCD. What makes it the high-end model in the line:

  • Multi-stage heating and cooling. The backplate carries staged terminals: W1/O/B, W2 and W3 for heating stages and Y1 and Y2 for cooling, so it can run a multi-stage system rather than a single on/off call.
  • Humidity control. Dedicated HUM and DEHUM terminals drive a humidifier and a dehumidifier.
  • Optional wireless module. The thermostat accepts a Wi-Fi, Z-Wave, ZigBee or Venstar RF module, and Venstar’s Wi-Fi path ties into a Skyport account.
  • Fully time-based program. You choose a 7-day, 5-1-1-day, 1-day or non-program schedule, each day with up to four periods.

Before You Start

The manual’s cautions are straightforward. Turn off power to the heating and cooling system before removing any wires. The T4900 is a 24 VAC low-voltage thermostat; it is not for line-voltage or millivolt equipment. If the thermostat you are removing contains mercury, recycle it rather than bin it. The guide also notes the unit can receive firmware updates from the manufacturer over its wireless module, which is worth knowing before you assume a screen is “wrong.”

Buttons and Display

The front of the T4900 has backlit buttons; the scrolling display walks you through the setup screens. The controls the manual identifies:

  • MODE moves between operating modes and advances through setup steps.
  • WARMER and COOLER raise or lower the setpoint, and change values in setup.
  • SETUP opens the user, installer and technician menus.
  • PROGRAM enters the time-period schedule.
  • FAN toggles constant fan; OVERRIDE forces occupancy; EMERGENCY runs emergency heat; SET CLOCK sets time and day.

The display shows icons for the current stage, the program period (Occupied 1, 2, 3 or Unoccupied), a heat or cool demand indicator (red for heat, green for cool), and, with a module installed, a wireless-connection icon.

Choosing a Mode

Press MODE to cycle the operating mode. The manual’s modes are Heat Only, Cool Only, Auto (Auto-Changeover) and Off. In Auto, the thermostat decides whether to heat or cool based on room demand, and pressing WARMER or COOLER shifts both the heat and cool setpoints together. To set them separately, switch to Heat or Cool, adjust, then return to Auto.

Setting the Clock and Day

Press SET CLOCK, then use WARMER or COOLER to set the time; press MODE to jump to the day, adjust, and press SET CLOCK again to confirm. A tip in the guide: hold the FAN button while pressing WARMER or COOLER to change the time in hours. If a Wi-Fi module is fitted, the clock is managed through the account and the local SET CLOCK step is not used.

Programming the Time Periods

Press PROGRAM to enter scheduling. First pick the program type: 7 Day lets every day differ, 5-1-1 groups weekdays and gives Saturday and Sunday their own schedule, 1 Day applies one pattern to all days, and Non-program runs a single fixed setpoint. Each programmed day uses up to four periods, named Occupied 1, Occupied 2, Unoccupied and Sleep in the display. Set a period’s start time with WARMER or COOLER and its heat and cool setpoints the same way, pressing MODE to advance. To save and exit, press PROGRAM; to copy one day to the next, press the up arrow then MODE, and press MODE again to push that day’s schedule to the following days.

Fan, Override and Emergency Heat

  • Fan. Press FAN for “Fan On,” which runs the blower continuously; press again to return to auto, where the fan runs only during a heating or cooling call. Fan On is not offered in the Off mode.
  • Override. During an unoccupied period, pressing OVERRIDE forces the thermostat into the Occupied 1 settings for 30 minutes; each extra press extends it.
  • Emergency heat. Only when the unit is set up for a heat pump, pressing EMERGENCY bypasses the compressor and runs the backup heat.

Wireless Modules and Holiday

The T4900 can carry one of four modules: Wi-Fi, Z-Wave, ZigBee or Venstar RF. Wi-Fi setup and status live under the Accessory menu, and Venstar’s Wi-Fi service uses a Skyport account; when a Wi-Fi module is present, some local functions such as setting the clock or the Holiday program move to the account. The Holiday feature runs temporary energy-saving settings for a set number of days without changing your normal schedule.

Installation and Wiring

The guide matches each labeled wire from the old thermostat to the same-letter terminal on the new one. The T4900 backplate terminals, from the manual:

TerminalFunction (from the manual)
R24 VAC power
C24 VAC common
W1 / O / BFirst-stage heat; on a heat pump, the reversing-valve (O or B) terminal
W2Second-stage heat
W3Third-stage heat
Y1First-stage cooling (compressor)
Y2Second-stage cooling
GFan relay
HUM / DEHUMHumidifier and dehumidifier control
AUXProgrammable auxiliary output
DRY CONTACTDry-contact switch input
OUTDOOR / REMOTE SENSOROutdoor and remote temperature sensors

Behind the board are dip switches that tell the thermostat what it is driving: an equipment switch (Gas/Electric or Heat Pump), a fan/aux switch, and, for heat pumps, an O or B switch for the reversing valve. The manual’s sample wiring covers conventional systems (3- and 4-wire) and heat pumps (5- and 6-wire with the O/B valve). To test the install, the guide sends you into Technician Setup, where each output can be exercised.

Installer Setup Highlights

Most of the T4900’s depth lives in Installer Setup, reached from the SETUP menu. The manual’s installer section covers: setpoint limits (three lock levels so a setpoint cannot be pushed past a floor or ceiling), stage deadbands and the minutes between stages, fan purge and other timers, humidify and dehumidify control, the programmable AUX output (by temperature, humidity or time), dry-contact and remote-sensor options, and a reset that returns every setting to its defaults. A technician screen adds sensor calibration and equipment testing.

Troubleshooting (From the Manual)

These are the guide’s own symptom, cause and remedy entries. Nothing here is added beyond the printed list.

SymptomCauseRemedy
Display is blankNo proper powerConfirm the furnace is powered and that there is 24 VAC between R and C.
AC will not turn onCompressor timer lockoutThe lockout delays the compressor; see the Installer Setup cycles-per-hour setting.
AC will not turn onCooling setpoint set too highLower the cooling setpoint or its limit in Installer Setup.
Heat will not turn onHeating setpoint set too lowRaise the heating setpoint or its limit in Installer Setup.
Heat pump calls cooling but heat comes onReversing-valve jumper set to BSet the reversing-valve jumper to O.
Both heat and cool come on in coolingEquipment jumper set to HP on a gas/electric unitSet the equipment jumper to Gas.
PROGRAM shows “DISABLED”Program mode set to Non-programSet the program mode to 1, 5-1-1 or 7 Day.

FAQ

How many heating and cooling stages does the T4900 run?

The backplate provides three heating stages (W1/O/B, W2, W3) and two cooling stages (Y1, Y2), and the installer setup includes stage deadbands up to a fourth heating stage. Stage control is configured during installer setup.

Can the T4900 work without the wireless module?

Yes. Every function runs from the buttons and display; the Wi-Fi, Z-Wave, ZigBee or Venstar RF module only adds remote control and account-based clock and holiday settings.

Why can’t I set the clock on the thermostat?

When a Wi-Fi module is installed, the clock is handled through the Venstar Skyport account, so the local SET CLOCK step is disabled.

What does pressing OVERRIDE do?

During an unoccupied period, OVERRIDE drops the thermostat into the Occupied 1 settings for 30 minutes, and each additional press extends that window.

How do I copy one day’s schedule to the rest of the week?

Program the first day, then press the up arrow and MODE to copy it to the next day, and press MODE again to repeat it across the following days.

Venstar support, the one-year limited warranty and full menus are covered at the back of the printed manual; for setup questions the guide points you to your installing dealer and Venstar.

Honeywell Lyric T5 Programmable Thermostat User Manual

Honeywell Lyric T5 Programmable Thermostat User Manual

This page is the Honeywell Lyric T5 Programmable Thermostat User Manual explained. The source is Honeywell’s official Lyric T5 Wi-Fi Programmable Thermostat User Guide, document number 33-3991, the booklet shown for model RCHT8610WF2006 (other Lyric T5 Wi-Fi models share it). The guide runs about 33 pages and covers the touchscreen, the Lyric app, scheduling, Wi-Fi, alerts, and troubleshooting.

Download Honeywell Lyric T5 Programmable Thermostat User Manual (PDF)

Contents

What the Lyric T5 Can Do

Page 3 lists the headline features. The Lyric T5 Wi-Fi is a connected touchscreen thermostat built around four ideas:

  • Flexible scheduling. Choose location-based control (geofencing), smart scheduling, a time-based schedule, or no schedule at all.
  • Smart Alerts. The thermostat sends notifications for things like extreme indoor temperatures and reminders for maintenance such as filter changes.
  • Automatic heat-to-cool changeover. In Auto mode it decides whether to heat or cool to reach the setpoint.
  • Smart Response. The unit learns your heating and cooling cycle times so it reaches the temperature you want at the time you want it.

The Lyric app can manage several thermostats and several people in one household, which matters for the geofencing behavior described later.

Touchscreen, System Modes, and Fan Modes

Three touch keys sit across the top of the display (pages 4 and 8): Mode selects the system mode, Fan selects fan operation, and Menu opens programming and settings. The center shows the current indoor temperature, and the small number is the desired temperature you change with + and -. The screen enters idle mode about 45 seconds after the last touch and may dim depending on the brightness setting.

System modes (page 8): Heat, Cool, Off, Auto (when enabled), and Em Heat (Emergency Heat). The guide is explicit that Em Heat only appears on heat pump systems with an auxiliary/emergency heat stage configured, that Auto mode is disabled by default, and that either mode may not show up depending on the equipment and how the thermostat was installed.

Fan modes (page 9): On runs the blower continuously, Auto runs it only during heating or cooling, and Circ (circulate) runs it at random intervals at least 35% of the time to keep air moving.

Built-in compressor protection (page 9): after a shutdown the compressor waits a few minutes before restarting to prevent damage. During that wait the screen flashes Cool On, or Heat On on a heat pump. The same flashing message also acts as a startup delay after an AC power loss.

Connecting to Wi-Fi and the Lyric App

To control the thermostat remotely it must join your home network through the Lyric app (page 10). The guide’s steps:

  1. Put your phone or tablet on a 2.4 GHz Wi-Fi signal. Many routers broadcast both 2.4 and 5.0 GHz; pick the 2.4 GHz one.
  2. At the thermostat, press and hold the indoor temperature in the center of the screen for 5 seconds until the screen changes.
  3. Install the Lyric app from the App Store or Google Play, open it, and tap SET UP NOW when the thermostat appears under “Thermostat Found.” If it does not appear, tap INSTALL A DEVICE.

A status icon in the upper-right corner shows whether Wi-Fi is connected, disconnected or not set up, or off. To move the thermostat to a new network (page 11), delete it first in the app under Thermostat Configuration, then hold the center temperature for 5 seconds and set it up again; your equipment settings and preferences are retained.

Scheduling and Overrides

Page 13 lays out the four scheduling styles. Location-based control uses your phone’s GPS: the thermostat drops to your Away temperature when you cross the geofence boundary on the way out and returns to your Home temperature when you cross back on the way in. Smart scheduling adds a Sleep period to that behavior. Time-based scheduling uses four periods per day, Wake, Away, Home, and Sleep, and can be the same every day, split weekday/weekend, or set a day at a time. If you do not want a program, select no schedule and adjust manually.

Overrides (pages 6 to 7) are how you depart from the program for a while. A Hold Until temporary hold changes the setpoint for up to 12 hours, or until a time you choose, then the schedule resumes; it is meant for time-based schedules. A Permanent Hold keeps a temperature until you change it or run the schedule again. A Vacation Hold suspends the program for a longer span and, the guide notes, can only be started from the Lyric app. In every case, touching Run Schedule ends the hold and returns to the program.

Page 12 maps the whole menu. From the home screen, touch Menu and arrow through these items:

  • Schedule (create or edit a program), Clean Screen (disables the touch layer for 30 seconds so you can wipe it), Temp Scale (Fahrenheit or Celsius), and Screen Lock (limits access to settings).
  • Wi-Fi (configure or change the network), Brightness, and Recovery (turn the Smart Response learning feature on or off).
  • Clock and Date (only manual when the thermostat is offline; a connected unit sets them itself), EQMT Status (live heating, cooling, and fan status), and Device Info (MAC ID, IP address, date code, model number, and firmware versions).
  • Alerts (only present when an active alert shows) and Reset.

Under Reset (page 24) the guide offers four choices: a return to the original settings (the menu item is labeled “Factory reset”), a Schedule reset back to the default Mon-Fri and Sat-Sun program, a HomeKit reset that clears Apple HomeKit credentials, and a Wi-Fi reset that clears the saved router credentials.

Alerts and Maintenance Reminders

Pages 26 and 27 print the alert list. When the alert symbol appears on the home screen, touch Menu then ALERTS; a three-digit code appears by the clock and a description scrolls. Non-critical alerts can be snoozed for up to seven days or dismissed; some critical alerts cannot. Representative codes:

Code Alert or reminder
164 Heat pump needs service; contact a heating/cooling professional
168 / 170 / 173 Wi-Fi radio error, internal memory error, or thermostat temperature sensor error; contact Lyric Technical Support
171 Set the date and time so scheduling works
175 AC power resumed after a loss; no action needed
181 / 182 Replace the air filter, then touch Dismiss to reset the timer
184 / 185 / 187 / 188 / 189 Humidifier pad, dehumidifier filter, ventilator filter, or UV bulb replacement reminders
210 / 388 Register online for outdoor temperature and remote access
399 / 400 / 508 No internet, no Wi-Fi signal, or Wi-Fi not configured

Compatibility Before You Install

Page 28 (“General system information”) carries the constraints that decide whether the Lyric T5 fits your system, plus three cautions. Quote them rather than guessing:

  • Compatible with most single-stage and multi-stage conventional and heat pump heating and cooling systems.
  • 24 VAC power through a “C” (common) wire is required.
  • Does not work with electric baseboard heat (120-240V) or with millivolt systems.
  • Remote control through iOS or Android; compatible with Apple HomeKit and Amazon Echo.
  • Heat setpoint range 40 to 90 °F (4.5 to 32.0 °C); cool setpoint range 50 to 99 °F (10.0 to 37.0 °C); sensor accuracy ±1.5 °F at 70 °F.

CAUTION: ELECTRICAL HAZARD. Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

CAUTION: EQUIPMENT DAMAGE HAZARD. Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

CAUTION: MERCURY NOTICE. If the Lyric T5 Wi-Fi thermostat is replacing a thermostat that contains mercury in a sealed tube, do not place the old thermostat in the trash. Contact your local waste management authority for proper recycling or disposal instructions.

Troubleshooting

Page 29 is the guide’s own troubleshooting list, reproduced here with only what the manual states.

Symptom What the manual advises
Thermostat screen is blank Check the circuit breaker or fuse for the heating/cooling system and turn it on if off. Make sure the power switch at the system is on. Make sure the furnace door is closed securely.
Screen is difficult to read Increase the screen brightness (Menu, then Brightness; see page 21).
Heating or cooling system is not responding Set Mode to Heat and make sure the setpoint is higher than the indoor temperature, or set Mode to Cool and make sure the setpoint is lower. Check the breaker/fuse, the system power switch, and the furnace door. Then wait 5 minutes for the system to respond.
Temperature setting does not change Make sure the setpoints are within range: heat 40 to 90 °F, cool 50 to 99 °F.
Cool On or Heat On is flashing Compressor protection is engaged. Wait a few minutes for a safe restart, then it clears on its own (see page 9).

Getting Help and Warranty

The guide’s welcome page lists support channels: lyric.honeywell.com, email MyLyric@honeywell.com, and Lyric Technical Support at 1-800-633-3991. Page 33 states a two-year limited warranty on workmanship and materials, with service handled through Honeywell Customer Care at 1-800-468-1502. Before you call, open Menu, then Device Info, and note the model number, MAC ID, and firmware versions, since those are what support will ask for.

If you are uninstalling or handing the home over, use the reset options on page 24 first. The guide is clear that the thermostat keeps your settings and router information in memory even when it is powered off, so clearing the schedule, Wi-Fi, and HomeKit credentials protects your account.

Honeywell TH6210U2001 T6 Pro Programmable Thermostat User Guide

Honeywell TH6210U2001 T6 Pro Programmable Thermostat User Guide

This page walks through the Honeywell TH6210U2001 T6 Pro Programmable Thermostat User Guide (document 00182EFS, Rev. 04-22). The T6 Pro is a five-button programmable thermostat for 20 to 30 VAC heating and cooling systems; the same guide also covers the TH6220U2000 and TH6320U2008. The points below follow the manual and cite its pages, and the PDF is linked here. Work from the guide whenever a screen or wire does not match what this summary shows.

Download TH6210U2001 T6 Pro User Manual (PDF)

Table of Contents

What the T6 Pro Is

The T6 Pro (TH6210U2001) is a programmable thermostat with a backlit screen and five physical buttons. From the guide’s overview and controls panel:

  • Programmable, four periods a day. Wake, Away, Home and Sleep, with different settings for weekdays and weekends.
  • Five buttons. Menu, Select, and the + and − navigation buttons, plus Mode and Fan.
  • Mode selection. Auto, Heat, Cool, EM Heat (emergency heat) and Off.
  • Status display. Cool On, Heat On, Em Heat On, Recovery and Compressor Protection are shown as they apply.

The guide notes the thermostat works with 20 to 30 VAC systems, and the electrical ratings table lists terminals including W, W2 (Aux) and Y2 alongside C, so a single- or multi-stage layout may apply depending on your model in this family.

Controls and Buttons

  • Menu. Opens the options list; this is also where you start a program schedule.
  • Select. Confirms the highlighted entry as you move through menus.
  • + and −. Raise or lower the temperature setpoint and move through menu items.
  • Mode. Cycles the thermostat between Auto, Heat, Cool, EM Heat and Off.
  • Fan. Switches the fan between Auto, On and Circulate.

Pressing any of the five buttons wakes the screen. When a C-wire supply is present, the backlight stays on and the screen does not sleep; on battery-only installations the display dims after a short period (the guide notes roughly eight seconds of lit display on battery).

Modes and Fan Settings

  • Auto. The thermostat chooses heating or cooling to reach the setpoint.
  • Heat. Heating only.
  • Cool. Cooling only.
  • EM Heat. Emergency heat on a heat-pump system that has auxiliary or backup heat.
  • Off. Both systems off.

Fan choices: Auto runs the blower only during heating or cooling; On runs it continuously; Circulate runs it for a scheduled slice of each hour to keep air moving.

Setting the Time and Date

The guide has you press Menu, then arrow down to TIME, then press Select to enter the clock. You pick 12- or 24-hour display, then adjust the hour and minutes with the + and − buttons, confirming each entry with Select. From the same Menu you reach DATE to set the year, month and day. Do this before you rely on any schedule; the periods trigger on the clock, not the temperature.

Programming the Schedule

Press Menu, then arrow to PROG and press Select. Choose ON to enable the program. You then pick the day or group of days to edit, then a period (Wake, Away, Home or Sleep), then set the time and the temperature for that period. Repeat for each period, and switch to the other day group to set it separately. Wake is when you get up and get ready for the day; Away is when you leave; Home is when you return in the evening; Sleep is overnight. The guide’s pre-set times are Wake 6:00 AM, Away 8:00 AM, Home 6:00 PM and Sleep 10:00 PM, and it recommends starting from the pre-sets because they can reduce energy cost. If you do not want a schedule at all, set PROG to OFF.

Overriding the Schedule

For a one-off change, press + or − on the home screen; the change lasts until the next scheduled period. To hold a temperature indefinitely, use the hold option in the menu; the guide shows how to return to the program from the same screen. Because heating and cooling are programmed separately, change the Mode if you need to adjust the other season.

Filter Reminders and Alerts

An alert icon appears on the home screen when a reminder is due. Press Menu, arrow to ALRT, and press Select to see which alerts are active. Press Select again to snooze the reminder for 7 days, or arrow to CLER and press Select to clear it. The guide notes some alerts cannot be snoozed or cleared; if that happens, service may be needed and you should call your heating and cooling professional.

Batteries

Two AA alkaline batteries power the T6 Pro. If the thermostat is wired to a C (AC) supply, the batteries are optional and act as backup power; if it is not C-wired, the batteries are required. Install fresh batteries as soon as the low-battery icon appears on the home screen. The guide notes the icon shows up about two months before the batteries are depleted, and recommends replacing them at least once a year or before a trip longer than a month. If new batteries go in within about two minutes of removing the old ones, the time and day stay set; the schedule and other settings are held in memory.

Troubleshooting (From the Guide)

These are the guide’s own troubleshooting items (p.7-8). Only what the manual lists; if your issue is not here, use the Customer Assistance line at the end.

Problem What the guide says to do
Display is blank Check and reset the circuit breaker; confirm the power switch at the heating/cooling system is on; make sure the furnace door is closed securely; install fresh AA alkaline batteries.
Heating or cooling does not respond Press Mode to set Heat (or Cool), and make sure the setpoint is higher (or lower) than the indoor temperature. Then check the circuit breaker, the system power switch and the furnace door, and wait about 5 minutes for the system to respond.
Temperature settings do not change Bring the setpoint inside the allowed ranges: Heat 40°F to 90°F (4.5°C to 32.0°C); Cool 50°F to 99°F (10.0°C to 37.0°C).
“Cool On” or “Heat On” is flashing Compressor protection is engaged. Wait about 5 minutes so the compressor can restart without damage.
A reminder keeps appearing Snooze from the ALRT menu for 7 days, or clear it with CLER; some alerts cannot be snoozed or cleared, and a service call may be needed.

Specifications and Support

  • Models covered by this guide: TH6210U2001, TH6220U2000 and TH6320U2008 (T6 Pro family).
  • Voltage: 20 to 30 VAC (the guide’s electrical ratings).
  • Program periods: four per day (Wake, Away, Home, Sleep), with weekday and weekend settings.
  • Modes: Auto, Heat, Cool, EM Heat and Off.
  • Fan modes: Auto, On and Circulate.
  • Setpoint range: Heat 40°F to 90°F; Cool 50°F to 99°F.
  • Power: two AA alkaline batteries; batteries optional when a C wire supplies AC power.
  • Compressor protection: built-in, about 5 minutes; shown as “Cool On” or “Heat On” flashing.
  • Warranty: 1-year limited (see the guide).
  • Support: https://www.honeywellhome.com/support; Resideo Technologies, Inc., 1985 Douglas Drive North, Golden Valley, MN 55422.

For exact dimensions, mounting height, torque and the wiring terminal-by-terminal table, the guide’s Installation Instructions and the wiring diagrams on the later pages are the authority; this page is a companion to that document.

FAQ

How many periods per day does the T6 Pro program?

Four: Wake, Away, Home and Sleep. You can set them differently for weekdays and weekends.

Does the T6 Pro have an emergency heat setting?

Yes. On heat-pump systems with auxiliary or backup heat, the Mode cycle includes EM Heat, which the guide also shows in the status display as “Em Heat On”.

Do I need a C wire?

Not strictly. The T6 Pro runs on two AA alkaline batteries; if a C wire supplies AC power, the batteries are backup and the display stays lit. Without a C wire the batteries are required and the screen dims after a few seconds when idle.

Why does “Cool On” or “Heat On” keep flashing?

Compressor protection is engaged. The guide’s troubleshooting section says to wait about five minutes so the compressor can restart safely.

Why do my setpoints stop at 40 or 90 degrees?

You hit the programming range. The guide lists Heat 40°F to 90°F and Cool 50°F to 99°F; anything outside is rejected while you set the schedule.

Honeywell Home T3 Pro Thermostat Installation Instructions Manual

Honeywell Home T3 Pro Thermostat Installation Instructions Manual

This page is for the Honeywell Home T3 Programmable Thermostat Installation Manual. The matching PDF on honeywellmanual.com is T3 Pro Thermostat Installation Instructions, document number 33-00520EFS-01 (M.S. 04-20, © 2020 Resideo Technologies, Inc.), a 36-page trilingual booklet with English on pages 1 to 12, French on pages 13 to 24, and Spanish on pages 25 to 36.

A note before you open the file: the “T3 Pro” line covers Honeywell Home’s non-programmable touchscreen thermostat, models TH3110U2008 and TH3210U2004. It has no weekly schedule; on the owner’s side you get a System mode selector, a Fan mode selector, and Installer Setup (ISU) for the technician. If the box says a programmable Honeywell Home model in the T5, T6, T9, or Wi-Fi 9000 family, this is the wrong document, and the model number printed behind the wallplate is the number to search instead.

Download T3 Pro Thermostat Installation Manual (PDF)

Contents

What Is in the Box

Page 1 lists the package contents directly. The T3 Pro box contains the thermostat itself, a UWP™ Mounting System, a small decorative cover plate sized 4.72″ H x 5.9″ W (120 mm x 150 mm), mounting screws and drywall anchors, two AA batteries, and the thermostat literature set (this Installation Instructions plus a user insert). If any item is missing, stop before drilling and check with the seller, because the UWP door and the R/Rc slider tab are both integral to the wiring steps.

Safety and Power Before You Start

Three cautions are printed on page 11 and govern the whole install. Quote them as written:

CAUTION: ELECTRICAL HAZARD. Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

CAUTION: EQUIPMENT DAMAGE HAZARD. Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

CAUTION: MERCURY NOTICE. If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

Both mounting pages open with the same operational rule: “Before starting, turn the power off at the breaker box or switch.” Do not rely on the wall switch alone when the air handler or furnace has a separate service switch.

Mounting the Thermostat

There are two mounting routes on pages 1 and 2, and you pick one depending on whether the old thermostat left marks on the drywall.

Optional cover plate installation. Use the cover plate when you need to hide paint gaps from the old thermostat. Mount the plate to the wall with any of its six screw holes, keeping it level and tightening without overtightening. Then hang the UWP on the top hook of the cover plate and snap its bottom into place. If there are no existing wall anchors, mark new holes and drill: 7/32″ (5.6 mm) for the red anchors and 3/16″ (4.8 mm) for the yellow anchors. The supplied screws pair by anchor color, #8 1-1/2″ (38 mm) with red and #6 1-1/2″ (38 mm) with yellow.

UWP Mounting System installation. Position the UWP on the wall, level it, mark both screw holes, and drill to the same 7/32″ or 3/16″ diameter depending on the anchor color. Pull open the UWP door and thread the wires through the wiring hole, then set the UWP over the anchors and tighten until the plate stops moving. Do not overtighten; close the door.

Final mounting on page 5: push excess wire back into the wall opening, close the UWP door so it sits flat without bulging, align the UWP with the back of the thermostat, and press gently until it snaps home. Then restore power at the breaker or switch.

Wiring: Terminals, Slider Tabs, and Diagrams

Power for the T3 Pro comes two ways at once. The UWP accepts a 24 VAC connection on R and C for primary power; the manual notes that C is optional if batteries are installed but is recommended. The two AA cells in the back cover primary or backup power. Wires release by pressing the terminal tab; never pull on the wire itself.

Page 3 lists every UWP terminal and what it does on a T3 Pro. Several are physically present but marked “Not used for T3 thermostat,” which is a common confusion when the old base has wires on them.

Terminal Function on a T3 Pro
R 24 VAC power from the heating transformer (shareable via slider tab)
Rc 24 VAC power from the cooling transformer (shareable via slider tab)
C 24 VAC common; for two-transformer systems, from the cooling transformer
W Heat (stage 1) on conventional systems. Do not use on heat pump applications
Y Compressor contactor, stage 1
G Fan relay
O/B Heat-pump changeover valve (configured in ISU 218)
AUX / W2 Auxiliary heat (TH3210U only)
E Emergency heat (TH3210U only)
S, L/A, A, Y2, U, K Not used for T3 Pro wiring (slider tabs on U terminals should stay in place)

The R/Rc slider tab. The UWP ships with a built-in jumper between R and Rc. If there is only one R wire, no matter whether it was landed on R, Rc, or Rh at the old thermostat, leave the slider in the up (one-wire) position. If one wire runs to R and a second to Rc, move the slider to the down (two-wire) position. The T3 Pro is a single-stage model, so the U-terminal slider tabs stay in place.

Pages 4 through 5 print wiring diagrams for eleven configurations. Conventional systems covered are 1H/1C with one transformer, 1H/1C with two transformers, heat-only, heat-only with fan, heat-only Series 20, heat-only power-open zone valve, and cool-only. Heat-pump systems covered are 1H/1C and 2H/1C with auxiliary heat (TH3210U only). Wire spec printed on page 4 is 18- to 22-gauge thermostat wire; shielded cable is not required.

System Modes and Fan Modes

Page 5 covers both selectors. Press Menu, then press the Mode (+) button to step through the available System modes, then press Done to lock one in. The manual lists these System modes: Auto, Heat, Cool, Em Heat (TH3210U only, on heat pumps with auxiliary heat, which locks out the compressor), and Off. It also notes that Heat On or Cool On may flash for five minutes because of compressor protection.

Press Menu, then the Fan (-) button to step through Fan modes. Auto runs the blower only when heating or cooling is active. On runs the blower continuously. If System is Off, the fan will still run when Fan is set to On.

Installer Setup (ISU) Reference

The T3 Pro enters ISU automatically the first time it is powered up after installation, and the manual tells the installer how to reach it later: hold the Menu button for about five seconds from the home screen. Inside ISU, press Edit (-) to change the value at the current step, press Next (+) to advance to the next setup number, and press Done to save and exit to the home screen. Every setup number is printed on pages 6 through 9. The table below collects the ones installers reference most; the numbers and defaults in bold match what the manual itself shows.

ISU number Purpose Options and notes
125 Temperature Indication Scale 0 = Fahrenheit, 1 = Celsius
200 Heating System Type 1 = Conventional forced-air heat, 2 = Heat pump, 3 = Radiant heat, 5 = None (Cool only); default varies by model
205 Heating Equipment Type (shown when 200 is Conventional or Radiant) Forced air: 1 = Standard-efficiency gas, 2 = High-efficiency gas, 3 = Oil, 4 = Electric, 5 = Hot-water fan coil. Radiant: 9 = Hot-water radiant, 12 = Steam
218 Reversing valve O/B (heat pump only) 0 = O (energized in Cool), 1 = B (energized in Heat)
220 Cool stages / Compressor stages 0 or 1 (set to 0 if there is no compressor or cooling stage)
221 Heat stages / Backup heat stages Heat fixed at 1; Backup heat 0 or 1
230 Fan control in Heat (shown when 205 is Electric forced air or Fan coil) 1 = Equipment controls fan, 2 = Thermostat controls fan
300 System changeover 0 = Manual, 1 = Automatic (turns the Auto System mode on the home screen)
303 Auto changeover differential 0 to 5 °F (0 to 2.5 °C). The manual distinguishes this from deadband, which is fixed by firmware and not adjustable
340 Backup heat droop (TH3210U only) 0 = Comfort, or a set droop from 2 °F up to 15 °F
350 Upstage timer to backup heat (TH3210U only) 0 = Off, 1 = 30 min, 2 = 45 min, 3 = 60 min, and so on up to 5 hours
365 Compressor cycle rate, stage 1 1 to 6 cycles per hour, shown only when Cool / Compressor Stage is set to 1
370 Heating cycle rate, stage 1 1 to 12 CPH. Defaults the manual lists by equipment: standard gas 5, high-efficiency gas 3, oil 5, electric 9, fan coil 3, hot-water radiant 3, steam 1
375 Heating cycle rate, auxiliary heat (TH3210U only) 1 to 12 CPH
387 Compressor protection 0 = Off, 1 to 5 minutes. When a call arrives during the delay the screen shows “Wait”
430 Minimum Cool setpoint 50 to 99 °F (10.0 to 37.0 °C); default 50 °F
431 Maximum Heat setpoint 32 to 90 °F (0 to 32.0 °C); default 90 °F
1400 Backlighting 0 = On demand, 1 = Continuous (requires a C-wire)
1401 Backlight brightness 1 to 5, shown only when Continuous is selected
1420 Temperature display offset -3 to +3 °F (-1.5 to +1.5 °C); 0 means the reading is unaltered

The manual closes ISU with a plain sentence: “You have now finished installing and setting up your thermostat.” There is no owner-side reset procedure in this booklet; if a full ISU wipe is needed, that is an installer task.

Specifications and Electrical Ratings

Page 10 lists the ratings that govern where the thermostat can be used.

Specification Value from the manual
Heat setpoint range 32 °F to 90 °F (0 to 32.0 °C)
Cool setpoint range 50 °F to 99 °F (10.0 to 37.0 °C)
Operating ambient temperature 32 °F to 102 °F (0 to 38.9 °C)
Shipping temperature -20 °F to 120 °F (-28.9 to 48.9 °C)
Operating relative humidity 5% to 90%, non-condensing
Thermostat size (H x W x D) 3.86″ x 5.36″ x 1.08″ (98 x 136 x 27.4 mm)
Decorative cover plate, small 4.72″ x 5.9″ (120 x 150 mm)
Terminal voltage (50/60 Hz) All outputs are rated 20 to 30 VAC
Running current, W / W2 (Aux) / Y 0.02 to 1.0 A (W2 is TH3210U only)
Running current, E / G / O/B 0.02 to 0.5 A
Wire gauge 18 to 22 gauge, unshielded

Troubleshooting

Page 10 carries the manual’s own short troubleshooting table. It is reproduced here with the exact fixes the manual gives; nothing is added.

Problem What the manual advises
Display is blank Check the circuit breaker and reset if necessary. Make sure the power switch for the heating and cooling system is on. Make sure the furnace door is closed securely. Make sure two fresh AA alkaline batteries are correctly installed (page 2).
Heating or cooling system does not respond Press the Mode button to set System to Heat (page 5) and make sure the desired temperature is set higher than the inside temperature. To test cooling, press Mode to set System to Cool and make sure the desired temperature is set lower than the inside temperature. Check the circuit breaker and reset if necessary. Make sure the power switch at the heating and cooling system is on. Make sure the furnace door is closed securely. Wait five minutes for the system to respond.
“Cool On” or “Heat On” is flashing The compressor protection feature is engaged. Wait five minutes for the system to restart safely, without damage to the compressor.
Aux heat runs during cooling For heat pump systems, verify there is no wire attached to W on the UWP. See “Wiring heat pump systems” on page 4.
Cool runs on a call for heat For heat pump systems, verify there is no wire attached to W on the UWP. See “Wiring heat pump systems” on page 4.

Getting Help and Warranty

Page 11 directs support questions to customer.resideo.com or Honeywell Customer Care at 1-800-468-1502, and the same page shows how to pull the thermostat off the UWP for a service call. The footer on page 12 lists the Resideo mailing address, 1985 Douglas Drive North, Golden Valley, MN 55422, and identifies the document as 33-00520EFS-01, marking revision M.S. 04-20, © 2020 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International, Inc.; the product itself is manufactured by Resideo Technologies, Inc. and its affiliates.

Because this document is a T3 Pro installation booklet, it does not carry a homeowner-side warranty statement. For warranty terms on a specific T3 Pro unit, check the printed card that shipped in the box or contact Honeywell Customer Care with the model number (TH3110U2008 or TH3210U2004) from the back of the thermostat.

Honeywell TH9320WF5003 WiFi 9000 Color Touchscreen Thermostat User Manual

Honeywell TH9320WF5003 WiFi 9000 Color Touchscreen Thermostat User Manual

The Honeywell Home TH9320WF5003 User Manual is Resideo’s owner guide for the Wi-Fi 9000 Color Touchscreen Thermostat. The document number is 69-2814EFS; the current printing is revision -12 with the cover mark M.S. Rev. 04-22 and copyright 2022 Resideo Technologies, Inc. Earlier printings (-05 and -07) carry the same core content with a Honeywell International copyright line.

A naming note that trips people up: the TH9320WF5003 is the Wi-Fi 9000 model, not the T9 Smart. Honeywell reused the TH9320 prefix across both, but the two lines use different apps and different hardware. The 9000 works through the Total Connect Comfort service in a browser or its mobile app; the T9 (TH9320WF3004) uses the Resideo app and pairs with the smart room sensors. If the box says “Wi-Fi 9000,” this manual is the one to use.

Scope of the guide: physical install is documented in a separate Installation Instructions booklet. The User Manual assumes the thermostat is already on the wall and covers Wi-Fi connection, registration with Total Connect Comfort, time and date, fan and system mode, the seven-day program schedules, temporary and permanent hold, vacation, business-mode holiday and occupancy features, screen color, preferences, and cleaning. Terminal assignments, wiring, and commissioning values belong to the install guide.

Key Features of the TH9320WF5003

The manual’s front matter (page 2) opens with what the thermostat can do once it is connected. Read it alongside Honeywell’s own product listing to confirm the underlying hardware:

  • Wi-Fi 2.4 GHz (802.11b/g/n) with Total Connect Comfort. Register the unit at mytotalconnectcomfort.com using the MAC ID and CRC printed on the thermostat.
  • Remote control and monitoring. View and set temperature and schedules from a browser or mobile app; automatic software updates over Wi-Fi.
  • Email alerts and outdoor weather. The manual notes that email alerts and the outdoor temperature and humidity display require Wi-Fi setup and registration.
  • 7-Day programmable. Selectable to 7-day programming or non-programmable. Four periods per day (Wake, Leave, Return, Sleep) with different weekday and weekend programs.
  • Color touchscreen. A large backlit display with customizable color themes; the screen can be set to match décor.
  • Multi-stage support. Rated for 24 V low-voltage HVAC systems, up to 3 heat / 2 cool on heat pump or 2 heat / 2 cool on conventional systems. The install guide covers terminals R, RC, C, W (or O/B), W2 (or AUX/E), Y, Y2, G, L, and K.
  • Home and Business modes. The manual carries a Business-screen quick reference alongside the Home layout, and Business-mode features such as Holiday/Event Scheduler, Custom Events, and Occupancy Mode.
  • Awareness features. Equipment status screen, filter and battery reminders, keypad lockout, and cleaning lock.

Document Structure

The 69-2814EFS User Guide is organized by task, and the printed page references below match the manual’s own table of contents. Knowing which page holds which feature makes it easy to answer questions on the phone or in a service ticket.

  1. About your new thermostat. What you can do through Total Connect Comfort, plus the Home-screen and Business-screen quick reference pages.
  2. Setting up your thermostat. Connecting to Wi-Fi (MENU, then Wi-Fi Setup), entering the network password, and confirming the “Connection Successful” screen.
  3. Registering your thermostat online. Creating or signing in to a My Total Connect Comfort account, then entering the MAC ID and CRC identifiers to bind the unit.
  4. Daily operation. Setting the time and date, setting the fan (On, Automatic, Circulate, or Follow Schedule), setting the system mode (Heat, Cool, Off, or Automatic), and reading the presets.
  5. Programming schedules. Preset energy-saving schedule, adjusting program schedules, and overriding schedules in Home or Business mode.
  6. Away and special situations. Vacation hold (home use), holiday and event scheduling, custom events, holiday override, and initiating occupancy mode (business use).
  7. Look and feel. Equipment status, customizing screen color, setting preferences, adjusting security (keypad lock), and cleaning the thermostat screen.
  8. Reference. Glossary, Regulatory Information (FCC Part 15.19, 15.21, 15.105(b) Class B; Industry Canada RSS-GEN 7.1.2 and 7.1.3), and the Resideo address block.

Wi-Fi Setup and Total Connect Comfort

The manual treats Wi-Fi and registration as two connected steps. Do them once, and every feature behind “remote access, alerts, and outdoor weather” unlocks.

  1. On the touchscreen, press MENU, then touch Wi-Fi Setup. The screen shows “Searching for wireless networks. Please wait…” then a list of available networks.
  2. Pick your network. Use the on-screen keyboard to type the Wi-Fi password, then touch Done. The unit replies “Connecting to your network. Please wait…” and then a “Connection Successful” screen.
  3. Press Next to reach the registration information screen. If you dismiss it before finishing, an orange alert appears on the home screen reminding you to register.
  4. In a browser, go to mytotalconnectcomfort.com, create or sign in to an account, and follow the Add Thermostat prompts. Enter the MAC ID and CRC that the thermostat displays; these are the unique identifiers that bind the unit to your account.
  5. After the site confirms the thermostat, the Total Connect Comfort screen displays SUCCESS and you can control the thermostat from the browser or the My Total Connect Comfort mobile app.

Programming and Daily Use

The Wi-Fi 9000 ships with a four-period preset schedule the manual prints on page 18. Weekday (Mon-Fri) values are Wake 6:00 a.m. at 70° heat / 78° cool, Leave 8:00 a.m. at 62° / 85°, Return 6:00 p.m. at 70° / 78°, and Sleep 10:00 p.m. at 62° / 82°. The Saturday-Sunday program uses the 6:00 a.m. and 10:00 p.m. periods at the same temperatures.

To change the schedule, follow the “Adjusting program schedules” steps in the manual:

  1. Touch MENU, then Create/Edit Schedule.
  2. Pick the mode: View/Edit for a quick change, Guide Me for the interview-style builder, or I’ll do it myself for full control.
  3. In “I’ll do it myself,” select the days you want to edit, then touch Next.
  4. Set the Wake time, then the heat and cool temperatures for that period. Touch Done to confirm.
  5. Repeat for LEAVE, RETURN, and SLEEP. Touch DELETE PERIOD to remove a period you do not want.
  6. Touch Done again to save and exit.

Everyday comfort tweaks use HOLD rather than editing the schedule. From the home screen, touch the temperature area to set a temporary hold with a “Hold Until” time; the schedule resumes when that time expires. Touch the option to switch to a permanent hold if you want the setting to stay until you resume the program schedule. In Business mode the hold duration is capped by the Override Duration value in Advanced Preferences.

Business installations get extra tools the manual walks through: a Holiday/Event Scheduler that can apply U.S. or Canadian holidays, custom one-off events scheduled by specific date or by month/weekday, a holiday override for an unplanned closure, and an Occupancy Mode that keeps the space at an energy-saving level until someone presses the button on arrival. The Home-use vacation-hold feature is simpler: MENU, then Vacation Mode, then the date you leave and the date you return.

Two maintenance touches round out daily use. Press MENU and select Equipment Status to see which heating, cooling, or fan outputs the thermostat is running right now. Press MENU and select Color Themes to change the screen to match the room, or to define a custom background and text color.

Important Safety Notices

The 69-2814EFS User Guide is not a wiring document. Wiring and commissioning safety belong to the Installation Instructions, and Honeywell Home’s thermostat support pages carry the standard warning verbatim:

Warning! Improper wiring or commissioning of your thermostat can cause unintended operation of your HVAC system which could lead to property damage, injury, including death. If you are unsure of what type of system you have, refer to your heating/cooling system equipment literature or call an HVAC professional.

  • 24 V systems only. The TH9320WF5003 is a low-voltage thermostat. It is not built for a 120/240 V line-voltage circuit such as electric baseboard heat, and it is not rated for the same terminals as a line-voltage controller.
  • Have wiring checked if you are unsure. The manual’s system-mode pages assume the install guide’s wiring was done correctly. If heat and cool behave as mirror images of each other, or if an unexpected output runs, stop and re-check terminal assignments against the install guide rather than adjusting settings at the touchscreen.
  • Screen cleaning. The “Cleaning the thermostat screen” page in the guide walks through the clean-screen lock so the display does not accept touches while you wipe it.

Where the User Guide does not answer a question (wiring, terminal map, installer setup codes, or a specific error on screen), consult the Installation Instructions or Resideo Customer Care before opening the unit.

Getting Help

The user guide prints two contact points on different pages. Its Total Connect Comfort section directs users to http://yourhome.honeywell.com and to 1-855-733-5465 for help registering the thermostat and using remote features. The -12 revision footer adds the Resideo Customer Care number 1-800-468-1502 and the mailing address at 1985 Douglas Drive North, Golden Valley, MN 55422. Have the model number, the MAC ID and CRC, and a photo of your wiring (only for install questions) ready before you call.

Two things worth knowing if you are shopping or replacing. Honeywell Home lists a 5-year limited warranty on this model. SupplyHouse’s listing also shows the unit as discontinued as of August 25, 2026, with the RTH9585WF1004 and TH9320WFV6007 listed as replacements. If you are troubleshooting an existing install rather than buying new, the guide is still the reference for programming, Total Connect Comfort, and Business-mode features.

Skip to PDF content
Honeywell FocusPro TH6320R Operating Manual

Honeywell FocusPro TH6320R Operating Manual

​Download the Honeywell FocusPro TH6320R Operating Manual (PDF)​

The file holds 21 pages of English. The contents list points to Spanish at page 20, French at page 40 and regulatory information at page 60, none of which are in this file. The inside cover carries the Quick Reference Card, which pulls out from under the body, and the help line 1-800-468-1502. It also warns against running cooling when the outdoor temperature is below 50°F (10°C), to prevent possible compressor damage.

Table of Contents

What the FocusPro TH6320R Is

Page 2 reduces the setup to four steps: set the time and day, which the booklet marks as required for proper operation; select the fan setting; select the system setting; and check the program schedules, which are preset to energy-saving levels on the assumption that the household wakes at 6 am, leaves at 8 am, returns at 6 pm and goes to bed at 10 pm. The same page notes that the schedule can be overridden at any time with one-touch temperature control. The contents list runs from programming and operation through to battery replacement, difficulty, warranty and regulatory information, and it contains no installation or wiring section.

The thermostat is the wireless part of the system. It reports a lost radio link as No Signal and restores that link by itself once power returns. The booklet also covers an optional remote control and an optional outdoor air sensor, and treats both as additions rather than requirements.

Controls and Display

Page 3 names five parts. There is the digital display, the battery holder at the side of the body, the up and down temperature buttons and the HOLD button. The last of the five is a row of four function buttons along the bottom, whose labels change with the task and appear on screen just above each button. Those labels are SET CLOCK/DAY/SCHEDULE, SET DAY, SET SCHEDULE, DONE, NEXT, CANCEL PERIOD, CANCEL, MORE and FIND REMOTE, depending on the screen.

Page 4 maps the display field by field.

Display itemWhat it showsPage
System settingHeat, Cool, Auto, Off or Em Heat7
Fan settingAuto or On6
Current program periodWake, Leave, Return or Sleep8-9
Set Clock/Day/ScheduleEntry point for the clock, the day and the schedule5, 9
Current inside temperatureThe measured room temperature–
RecoveryShown while Adaptive Intelligent Recovery is working15
Low battery warningsThermostat and outdoor sensor cells16-17
System statusHeat On or Cool On, flashing during compressor protection15
Auxiliary heatOnly for heat pumps with auxiliary heat–
MoreOutdoor climate if a sensor is installed, or find a misplaced remote14
Current time and dayThe clock setting5
Temperature settingThe setpoint in use9-11

Setting the Time and Day

Press SET CLOCK/DAY/SCHEDULE and use the arrows to set the clock. Press SET DAY and use the arrows to select the day of the week. Press DONE to save.

Two notes sit under the steps. If the SET CLOCK/DAY/SCHEDULE option is not displayed, press DONE or CANCEL. If the display flashes Set Clock, the thermostat follows the settings for the weekday Wake period until the time and day are reset.

Fan, System and Auto Changeover

FAN selects Auto or On. In Auto, which the booklet calls the most commonly used setting, the fan runs only when the heating or cooling system is on; on On it runs continuously. Options may vary with the equipment.

SYSTEM selects Heat, Cool, Off, Auto or Em Heat. Heat controls only the heating system and Cool only the cooling system, while Off turns all systems off. Auto lets the thermostat choose heating or cooling according to the indoor temperature. Em Heat applies only to heat pumps with auxiliary heat: it controls emergency and auxiliary heat with the compressor locked out.

Auto changeover is the feature behind Auto, and the booklet gives it to climates where air conditioning and heating are used on the same day. Heat and cool settings must be at least 3 degrees apart, and the thermostat adjusts them to keep that separation. The Auto setting may not appear at all, depending on how the thermostat was installed.

The Preset Schedule

The page heading reads Energy-saving settings for maximum cost savings. The booklet states that the preset can reduce heating and cooling expenses by as much as 33%. Four periods run through the day: Wake at 6:00am, Leave at 8:00am, Return at 6:00pm and Sleep at 10:00pm.

PeriodHeat (Mon-Fri)Cool (Mon-Fri)Heat (Sat-Sun)Cool (Sat-Sun)
Wake (6:00 am)70°F78°F70°F78°F
Leave (8:00 am)62°F85°F62°F, or cancel period85°F, or cancel period
Return (6:00 pm)70°F78°F70°F, or cancel period78°F, or cancel period
Sleep (10:00 pm)62°F82°F62°F82°F

The cancel option appears only on the two middle periods of the weekend columns.

Editing, Overriding and Holding

To change a time or temperature, press SET CLOCK/DAY/SCHEDULE and then SET SCHEDULE. Use the arrows to set the weekday Wake time and press NEXT, then the arrows for that period’s temperature and NEXT again. Repeat for Leave, Return and Sleep, press NEXT to reach the weekend periods, and DONE to save and exit. The three buttons on this screen are DONE, CANCEL PERIOD and NEXT, and a note asks you to confirm that the thermostat is set to the system you intend to program, Heat or Cool.

The arrows also work during normal operation. Pressing one adjusts the temperature at once and overrides the current period only; the display shows the new setting with Hold Until and the time that period ends, and CANCEL returns the schedule immediately.

HOLD is the permanent version. It overrides the temperature settings for every period, turning the schedule off so the thermostat can be adjusted by hand. Whatever temperature is set is maintained 24 hours a day until it is changed or CANCEL is pressed.

Remote Control and Outdoor Sensor

An optional remote control can act as a mobile thermostat, holding a comfortable temperature as you move between rooms. While the system responds to temperatures measured at the remote, the display reads Remote has Control, and CANCEL hands control back to the thermostat. The booklet warns that the thermostat may take up to 15 seconds to respond to commands entered at the remote, and refers to a separate Remote Control Operating Manual.

With an outdoor air sensor fitted, MORE shows the outdoor temperature and humidity, and DONE exits. MORE then FIND REMOTE makes a misplaced remote beep for two minutes; pressing anywhere on the display stops the beeping.

Special Features and Batteries

Built-in compressor protection keeps the compressor from restarting too soon after shutdown. It forces a wait of a few minutes, and during that time the display flashes Cool On, or Heat On on a heat pump. Adaptive Intelligent Recovery lets the thermostat learn how long the furnace and air conditioner take to reach the programmed settings. The temperature then arrives at the time you set, and the word Recovery appears while the feature is working.

REPLACE BATTERY begins flashing about two months before the cells are depleted, and the inside cover puts the interval at once a year. Remove the battery holder and fit 2 fresh AA alkaline batteries, and communication with the wireless network resumes within a few minutes. The note adds that batteries inserted within 2 minutes, printed as t2 minutes, save the time and day from being reset, while all other settings stay in memory either way. The outdoor air sensor takes 2 fresh AA lithium batteries and has its own REPLACE BATTERY OUTDOOR warning with the same two-month lead. It is reloaded by taking the sensor off its bracket and removing the cover.

In Case of Difficulty

Page 18 prints two entries in two columns, symptom on the left and action on the right.

SymptomWhat to do
Heating or cooling system does not respond
  • Check circuit breaker and reset if necessary.
  • Make sure power switch at heating & cooling system is on.
  • Make sure furnace door is closed securely.
  • Wait 5 minutes for the system to respond.
Screen displays “No Signal”

Thermostat has lost radio contact with the wireless network (usually because of a power outage). To restore power:

  • Check circuit breaker and reset if necessary.
  • Make sure power switch at heating & cooling system is on.
  • Make sure furnace door is closed securely.

After power is restored, the thermostat will automatically restore wireless communication within a few minutes.

The warranty runs three years from the date of purchase, excluding the battery, and extends to five years once the product is registered online at www.warranty.Honeywell.com. A defective unit goes back to the place of purchase with a bill of sale, or through Honeywell Customer Care on 1-800-468-1502, which decides whether it is returned to Golden Valley, Minnesota, or replaced. Removal and reinstallation costs are not covered. Canadian owners are given a Toronto address for written enquiries.

Frequently Asked Questions

Do I have to program the thermostat before using it?

No. The thermostat is pre-programmed with energy-saving settings, and only the time and day must be set for proper operation. After that, check the fan setting, the system setting and the schedule.

How far apart must the heat and cool settings be in Auto?

At least 3 degrees. The thermostat adjusts the settings itself to keep that separation, and the Auto setting may be missing entirely depending on how the thermostat was installed.

What is the difference between the arrows and HOLD?

The arrows override only the current period, and the display counts down to the time it ends with Hold Until. HOLD overrides every period and keeps one temperature 24 hours a day until you change it or press CANCEL.

Which batteries does it take?

Two AA alkaline in the thermostat, fitted in the battery holder at the side of the body. The outdoor air sensor takes two AA lithium, a different type, and warns through its own REPLACE BATTERY OUTDOOR message.

Why is Cool On flashing?

The built-in compressor protection is holding the compressor for a few minutes after shutdown, and the message flashes during that wait. On a heat pump the same state shows Heat On.

Honeywell Thermostat CM921 User Manual

Honeywell Thermostat CM921 User Manual

The Honeywell Thermostat CM921 User Manual is a 19-page booklet, document 42011077-103 R1, dated 2006 and published by Honeywell Control Systems Ltd. The CM921 is a 1 day wireless programmable room thermostat that talks to an HC60NG relay box, so no thermostat cable runs between the two. This page follows it through setup, programming, the modes, the holiday function, the user parameters, cooling and the eight faults it prints.

Download the Honeywell CM921 User Manual (PDF)

Table of Contents

What Is the Honeywell CM921?

Page 1 describes the CM921 as a wireless programmable room thermostat designed to control a heating system efficiently, providing comfortable temperatures when you are at home and energy savings when you are away. The link to the boiler is wireless, so the booklet covers no wiring for the thermostat itself; the connections sit at the boiler and the HC60NG relay box. The unit has a backlit LCD, an OK confirm key, six temperature levels per day, a holiday button, automatic summer and winter time change, and a memory that holds the program when the batteries come out. Optimum Start and the OFF-mode frost value are installer settings.

Controls and Display

Page 2 prints a numbered drawing of fifteen parts. The instructions use the slider switch with its five positions, DATE, PROG, AUTO, MAN and OFF; the up and down temperature arrows; the green OK button; the left and right program arrows; the enquiry button marked with an i; the holiday button marked with a suitcase; and the plus and minus time buttons.

Setup: Batteries, Date and Time

Step 1: Fitting the Batteries

Follow these steps only if the screen is blank, with no symbols or digits displayed.

  1. Lift up the front cover to reveal the battery cover.
  2. Remove the battery cover by pressing down and sliding it out.
  3. Insert the two AA LR6 alkaline batteries supplied with the thermostat, watching the orientation on page 2; the screen then displays information and the unit is ready.
  4. Replace the cover by sliding it firmly back.

The cells are alkaline LR6, and used ones are to be disposed of carefully.

Step 2: Setting the Date and Time

Move the slider to DATE. SET THE DAY appears and the day digits flash; the up or down arrow shows DAY OK? while pressed, and the green button confirms. The month and year follow the same way, and an invalid date returns the thermostat to the start of the mode.

The time digits then flash with SET THE TIME. Each press moves one minute, and holding the button changes the time slowly and then progressively quicker. CHANGES SAVED appears, then DATE COMPLETE; moving the slider before that point discards the changes.

Step 3: First Run

With the date and time set, move the slider to AUTO and the built-in program runs. The booklet describes no pairing or commissioning procedure for the radio link.

Programming the Six Periods

The built-in program has six temperature level changes, settable between 3.00am and 2.50am, each level between 5°C and 35°C in 0.5°C increments. The default program is printed on page 5.

Period 1 2 3 4 5 6
Time 6:30 8:00 12:00 14:00 18:00 22:30
Temperature 21°C 18°C 21°C 18°C 21°C 16°C

Move the slider switch to PROG and use the left and right arrows to move between the six periods; a flashing square at the bottom of the screen marks the current one.

Changing a Period

The screen shows SET TIME 1 with the time flashing. Press an arrow and TIME 1 OK? appears; holding the button changes the time quickly, and if the next change period flashes, that next change is pushed forward if you keep pressing. The green button confirms and SET TEMP 1 follows; adjust until TEMP 1 OK? appears, confirm, and SET TIME 2 follows. Repeat for all six periods, or move the slider to AUTO at any point. Ten minutes without input brings MOVE THE SLIDER on screen.

Any period from 2 to 6 can be disabled. In PROG, reach it with the left and right arrows, check the flashing square, then hold the enquiry button for at least 2 seconds. To restore one, navigate to it, where the screen shows DISABLED, and hold the same button until ENABLED appears.

Operating Modes and the Holiday Function

AUTO, MAN and OFF

AUTO follows the temperature program, default or personalised, which the booklet calls the best way to maintain comfort while maximising energy savings. MAN acts as a simple thermostat with a fixed setpoint, adjustable from 5°C to 35°C and held until another mode or temperature is selected. OFF controls to 5°C by default as frost protection, a value adjusted by calling your installer.

Room, Target and Frost Temperature

In AUTO and MAN the display shows the room temperature with ROOM TEMP. Pressing the enquiry button flashes the target temperature with TARGET TEMP for 5 seconds; in OFF the same button shows FROST TEMP. The up or down arrow overrides the programmed temperature for 5 seconds, ending at the next programmed change. The plus or minus buttons adjust the clock, confirmed with the green button.

The Holiday Function

The holiday function holds a constant temperature, 10°C by default, for 1 to 99 days, saving energy and related costs while the home is empty. In AUTO or MAN, press the holiday button: the day after the current day is selected with RETURN DATE OK?, and the plus or minus buttons set 1 to 99 days. The green button confirms, then TEMP OK? allows 5°C to 35°C. HOLIDAY MODE stays displayed until the return date, the counter dropping by one at midnight, and the thermostat resumes the mode set on the slider. Press the holiday button again, or move the slider, to cancel.

User Parameters, Cooling and the HC60NG

The Three User Parameters

Move the slider to OFF, then hold the enquiry button for about 5 seconds; CLOCK SELECT appears with the current setting.

Parameter How to reach it Values Page
Clock select First screen on entering user mode 12 = AM/PM format, 24 = 24hr format 11
Reset program Press the plus time button once 0 = user program, 1 = built-in program 11
Auto change Press the plus time button twice 0 = disabled, 1 = enabled 11

The up or down arrow selects each value, the display flashes, and the green button confirms it; move the slider to exit. Selecting 1 on RESET PROGRAM restores the built-in program and discards the personalised one, and clock select changes how the time is displayed, not the time itself.

Switching to Cooling

Cooling needs a correctly set up system. Press the up and down arrows together for 5 seconds in any mode and COOLING appears. The cooling program uses the same six times with its own temperatures, edited through PROG:

Period 1 2 3 4 5 6
Time 6:30 8:00 12:00 14:00 18:00 22:30
Temperature 24°C 28°C 24°C 28°C 24°C 24°C

The HC60NG Relay Box

The HC60NG is the relay box that receives the radio signal, with a push button and relay status LEDs. The green LED indicates normal operation of the radio frequency system, on when the boiler is on. A red LED, steady or flashing, means radio communication has been lost, which the location of the thermostat may explain, or a radio fault, which is a call to the installer. While communication is lost the boiler can be switched with the push button.

Troubleshooting: The Eight Entries

Pages 12 and 13 print eight entries in three columns, Symptom, Possible Cause and Remedy, four on each page, several with more than one cause. They appear in the booklet’s order and grouping, with icons named as the battery, flame and spanner symbols.

Symptom Possible cause Remedy
The thermostat has a blank LCD screen. Batteries not installed. Check to see if there are batteries in the battery compartment and the paper tab has been removed.
Incorrect battery orientation. Check that the batteries have been installed in the correct orientation.
Exhausted batteries. Replace with new batteries.
The thermostat shows a flashing battery symbol on the LCD screen. Batteries are exhausted and need replacing. Replace with new batteries.
The thermostat’s LCD display shows a flame symbol but the heating does not switch on. The heating is not required at this moment. The heat demand is sent to the HC60NG as a value between 0-100%. The HC60NG will adjust the boiler on time to meet this requirement. That is why the heating will be off sometimes even if the flame symbol is displayed. To check if the RF system is communicating properly, press the up arrow button to increase the set temperature a few degrees above the current temperature. The heating should come on after a few seconds.
The thermostat shows a flashing spanner symbol on the LCD screen. Fault in thermostat. Remove and re-insert the batteries in the thermostat. If the spanner symbol does not clear itself in a few minutes, call the installer.
The thermostat’s LCD display works but the heating does not switch on (HC60NG LEDs are off or green one is on). No power to heating system. Check that there is power to the heating system.
Program does not call for heat. Move the slider switch to MAN and press the up arrow to increase the temperature a few degrees above the current room temperature. The heating should come on after a few seconds.
Wrong electrical connection. Call electrical installer to check the boiler and HC60NG power supply as well as the connection between the boiler and the HC60NG.
The red LED on the HC60NG is constantly on or flashing. RF communication lost due to the wrong location of the thermostat. Hook the thermostat back on the wall bracket or replace the thermostat on the table stand in the position where RF communication was reliable.
RF communication fault. Call installer. Note: you can control the boiler manually when the RF communication is lost. Press the HC60NG push button to switch the boiler on and off. When the green LED is on, the boiler is on.
Heating switches ON or OFF too slowly or quickly. The thermostat not set correctly for your system. Call Installer.
Temperature swings between too hot and too cold. The thermostat not set correctly for your system. Call Installer.

Frequently Asked Questions

How long do the batteries last and how do I change them?

About two years. A flashing battery symbol shows when power is running low, and the cells are changed by following the battery steps on page 3 with new AA LR6 cells.

Can I hold one temperature all day?

Yes. Move the slider to MAN and set the temperature with the arrows, 5°C to 35°C in 0.5°C steps; it is held until another mode or temperature is selected.

What is Optimum Start?

A function that starts the heating earlier on cold days and later on warmer ones, to save energy. If it is in use, enter the times you want to be warm, not the times you want the boiler to fire. The booklet lists it as an installer option.

Where can I put the thermostat if I use the table stand?

Where reliable radio communication has been proven, with your installer checking the spot. The unit measures the temperature of the room it is in, so keep it away from draughts, sunlight and heat sources, 30 cm from metal and 1 metre from other electrical equipment.

Honeywell The Round CT87K Owner's Manual

Honeywell The Round CT87K Owner’s Manual (PDF)

The Honeywell CT87K Owner’s Manual is the official installation-and-operation booklet for Honeywell’s classic “The Round” non-programmable, dial-operated room thermostat. The document number is 69-1959EFS-02, a 16-page trilingual guide (English on pages 1-5, French on 6-10, Spanish on 11-15). It covers two physically similar models together: the CT87K for 24 VAC heating systems, and the CT87N for 24 VAC heating and cooling systems. If your wall dial only has an R and a W connection and no system or fan switch, the CT87K sections are the ones you need.

The CT87K is a mechanical setpoint dial, not a digital programmable thermostat. You set the temperature by rotating the round face; there is no schedule, no app, and no keypad. That simplicity is exactly why it is still installed in a lot of homes and small commercial spaces, and why the manual itself is short. The whole booklet fits on five English pages: package contents, removal of the old unit, wallplate mounting, wiring by terminal, two small configuration switches, and a one-line operating instruction.

Before wiring anything, verify you have the right model. The manual warns that if your old thermostat has four or more wires (not counting C or C1), you may have bought the wrong replacement for a CT87K. In that situation it tells you to stop and call Honeywell at 1-800-468-1502 for advice.

Key Features of the CT87K

The CT87K’s feature set is deliberately small. Honeywell’s Owner’s Manual and the corresponding retail listing describe a non-programmable, single-stage heat-only dial thermostat with a 24 VAC control circuit, 1-year limited warranty, Premier White housing, 3.69 in x 3.69 in x 1.09 in (94 x 94 x 28 mm) dimensions, and an optional decorative cover plate for hiding old marks. The owner-facing details that matter day to day are:

  • Rotary setpoint dial. Turn the round cover to the temperature you want; the ring shows current and desired indoor temperature.
  • Heat-only operation. The CT87K controls a single heating stage. It has no System switch and no Fan switch; those live on the CT87N sibling.
  • Two configuration switches inside the base. The pair of cycle-rate switches is set once during installation to match your heating equipment (see the table below).
  • Terminal block for R, W, and Y. The CT87K uses Y as the third conductor on a 3-wire hot-water heat-only valve circuit, not for cooling.
  • Optional decorative cover plate. Fits behind the base to hide marks left by the previous thermostat.
  • 24 VAC control power only. The Owner’s Manual lists the CT87K as being for 24 VAC heating systems. Do not install it on a line-voltage electric baseboard circuit.

The CT87N, which shares the manual, is the version to buy when you need heat, cool, and a fan switch as well as the dial.

Document Structure

The English portion of 69-1959EFS-02 runs in a fixed order. Knowing the layout is quicker than scrolling through a preview.

  1. Getting started (page 1). Package contents (thermostat, cover plate, wall anchors and screws, wire labels) and required tools: No. 2 Phillips and small pocket screwdrivers, hammer, level, pencil, and a drill bit sized 3/16 in for drywall or 7/32 in for plaster.
  2. Remove your old thermostat (page 1). Turn off power, remove the cover, leave the old wallplate in place, and check for a sealed mercury tube.
  3. Label wires and remove the old wallplate (page 2). Wrap each wire with the letter label that matches the old terminal, then remove the old wallplate. Includes the “wrong replacement” wire-count check and a table mapping common old-terminal letters to CT87N and CT87K terminals.
  4. Mount the base and connect wires (pages 2-3). Mark screw holes, drill and insert anchors, thread the wires, and tighten the terminal screws. Includes the notes about removing the R-Rc jumper, choosing O versus B on a heat pump, and taping off unused conductors.
  5. Configure the switches (page 4, CT87N sections apply when present). The fan-operation switch has an E and F position; the cycle-rate switches 1 and 2 have a four-row setting table for steam, high-efficiency, gas/oil, and electric systems.
  6. Finish installation (page 4). Snap the thermostat onto the base, restore power.
  7. Operation (page 5). The CT87N has a System switch (Cool, Heat, Off) and a Fan switch (On, Auto). Both models set temperature by rotating the dial.
  8. Warranty. The Owner’s Manual closes with the one-year limited warranty statement.

Wiring and Configuration

The CT87K terminal block carries R, W, and Y. The manual maps the older Honeywell or generic terminal letters to those three. Existing labels connect as follows:

  • R, Rh, 4, or V → new R terminal.
  • W, W1, or H → new W terminal.
  • Y or Y1 or M → new Y terminal.
  • C, X, or B → not used on the CT87K. Wrap the bare end with electrical tape and leave it disconnected.

The manual gives two wiring recipes for the heat-only model. A two-wire heat-only system uses only R and W. A three-wire hot-water heat-only system uses R to R, W to W, and Y to Y, which drives an open/close zone valve. Do not rely on wire color; label by the terminal letter on the old unit.

Cycle rate switches

Inside the base are two small switches, labeled 1 and 2, that set how often the thermostat cycles the equipment. The Owner’s Manual gives one row per heating type:

Heating systemSwitch 1Switch 2
Steam or gravityOnOn
High-efficiency warm air (90% plus), hot water, or heat pumpOffOn
Gas or oil warm air (factory setting)OffOff
Electric warm airOnOff

Set both switches before you snap the cover on, because they are not reachable from the front. If you are replacing an identical CT87K, note the old switch positions in a photo before you remove the wires.

Setting the Temperature

Operation is a single action: rotate the round face to the number that matches the temperature you want the room to hold. The ring shows both the current indoor reading and the setpoint. There is no program, no hold, and no schedule to cancel; the CT87K keeps calling for heat until the room reaches where you turned the dial. If you need a heat/cool/off selection or a fan On/Auto switch, that is the CT87N’s System and Fan switch page in the same manual, not the CT87K.

Important Safety Notices

The CT87K Owner’s Manual carries four safety statements that are worth reading before the screwdriver comes out:

  • Turn the power off first. Step 1 of the removal procedure reads: “CAUTION: TURN OFF POWER to system at the furnace, or at the fuse/circuit breaker panel before you begin.” Do not remove or touch low-voltage wiring until you have confirmed power is off at the equipment.
  • Mercury disposal. The manual’s MERCURY NOTICE says that if your old thermostat contains mercury, you should contact your local waste-management authority for proper disposal instructions rather than placing it in the trash.
  • Lithium / perchlorate cell. The Owner’s Manual states the thermostat contains a lithium battery that may contain perchlorate material and that special handling may apply; it points to the California DTSC perchlorate guidance.
  • Cooling low-temperature caution. The CT87N version of the manual adds: “CAUTION: EQUIPMENT DAMAGE HAZARD (CT87N). Do not operate cooling system when outdoor temperature is below 50°F (10°C).” The CT87K is heat only and does not have that feature, but the same rule applies to any connected cooling equipment.

If you are not comfortable removing the old thermostat, if the wire labels do not line up with the CT87K terminals, or if your existing wiring uses more conductors than the CT87K expects, stop. Call Honeywell at the number in the manual or hire a licensed HVAC technician rather than guessing at a low-voltage connection.

Getting Help

The Owner’s Manual itself directs users to 1-800-468-1502 when the wire count does not match the CT87K’s expected two- or three-conductor heat-only circuit. Honeywell Home (a Resideo brand) also publishes the 69-1959EFS document and a companion Range Stops PDF on its support site under “The Round Non-Programmable Thermostat” listing. If you need the exact English wording for a warranty claim, note the model number (CT87K1004 or your variant), the date of purchase, and the terminal layout you used.

Download PDF: Honeywell The Round CT87K Owner’s Manual.pdf

Honeywell VisionPRO TH8000 Series Installation Manual

Honeywell VisionPRO TH8000 Series Installation Manual

This Honeywell VisionPRO TH8000 Series Installation Manual is the 12-page guide for the touch-screen TH8321U1097, the only model listed on page 1. It covers wiring for conventional, heat pump, and IAQ systems, plus 70+ installer setup functions and system tests. The document is form 69-2389-03, © 2011 Honeywell International Inc.

Download Manual (PDF)

Table of Contents

What the Manual Covers

Page 1 lists one model: “TH8321U1097: For up to 3 Heat/2 Cool heat pump or up to 2 Heat/2 Cool conventional systems with dehumidification, humidification, or ventilation”. To find your model number, “(Pull thermostat from wallplate and turn over to find model number)”. This VisionPRO TH8000 wiring guide covers the TH8321U installation for touch-screen programmable control.

The manual opens with three notices: a perchlorate warning for the lithium battery, a mercury notice if replacing an old control, and an electrical hazard caution: “Can cause electrical shock or equipment damage. Disconnect power before beginning installation.” The guide states: “Must be installed by a trained, experienced technician”.

Before You Install

Page 2 covers wallplate installation. “Separate wallplate from thermostat.” Mount it with “Drill 3/16″ holes for drywall. Drill 7/32″ holes for plaster.” After wiring, “Push excess wire back into the wall opening. Plug wall opening with non-flammable insulation.”

Page 6 shows how to mount the thermostat: “Remove tab. Align pins on back of thermostat with slots in wallplate, then push gently until thermostat snaps into place.” Then set the date and time before entering installer setup.

TH8000 Series Terminal Designations

Page 3 defines terminals for conventional and heat pump systems. Both share R (system power), C (common), S1/S2 (optional outdoor sensor), and U1/U1 (optional IAQ device). These TH8000 Series terminal designations apply to all wiring configurations.

Conventional terminals (page 3)
Terminal Function
R System power. Connect to secondary side of system transformer.
C Common wire from secondary side of transformer.
W 1st stage heat relay.
W2 2nd stage heat relay.
Y 1st stage compressor contactor.
Y2 2nd stage compressor contactor.
G Fan relay.
S1/S2 Optional outdoor/remote/discharge sensor.
U1/U1 Optional IAQ device.
Heat pump terminals (page 3)
Terminal Function
R System power.
C Common wire.
Y 1st stage compressor contactor.
Y2 2nd stage compressor contactor.
E/Aux Auxiliary/Emergency heat relay.
G Fan relay.
L Heat pump reset (powered continuously when System is set to Em Heat; system monitor when set to Heat, Cool or Off).
O/B Changeover valve for heat pumps.
S1/S2 Optional outdoor/remote/discharge sensor.
U1/U1 Optional IAQ device.

Wiring Diagrams for Conventional Systems

Page 4 shows six conventional configurations for VisionPRO TH8000 wiring. Each lists the terminals used and any notes.

Conventional system wiring (page 4)
System Terminals Notes
1H/1C (1 transformer) R W Y G C S1/S2 U1/U1 [1, 6]
Heat Only R W C S1/S2 U1/U1 [1]
Heat Only (Series 20) R W Y C S1/S2 U1/U1 R to Series 20 “R”, W to “B”, Y to “W”
2H/2C (1 transformer) R W W2 Y Y2 G C S1/S2 U1/U1 [1, 6]
Heat Only With Fan R W G C S1/S2 U1/U1 [1, 6]
Cool Only R Y G C S1/S2 U1/U1 [1]

Notes: “[1] Power supply. Provide disconnect means and overload protection as required.” “[2] Optional 24VAC common connection.” “[6] Only works with single transformer systems.”

Heat Pump Wiring Diagrams

Page 5 covers four heat pump configurations for VisionPRO TH8000 heat pump wiring systems.

Heat pump system wiring (page 5)
System Terminals Notes
1H/1C Heat Pump (no aux) R Y G C O/B S1/S2 U1/U1 [1, 3]
2H/1C Heat Pump (with aux) R Y G C E/Aux L O/B S1/S2 U1/U1 [1, 2, 3, 4, 5]
2H/2C Heat Pump (no aux) R Y Y2 G C O/B S1/S2 U1/U1 [1, 2, 3]
3H/2C Heat Pump (with aux) R Y Y2 G C E/Aux L O/B S1/S2 U1/U1 [1, 2, 3, 4, 5]

Notes: “[3] O/B set to control as either O or B in installer setup.” “[4] If L terminal is used, 24VAC common (terminal C) must be connected.” “[5] Heat pump reset (powered continuously when thermostat is set to Em. Heat; system monitor when set to Heat, Cool, or Off).”

IAQ Wiring (Humidification, Dehumidification, Ventilation)

Page 5 also shows six IAQ device configurations, all using the U1/U1 terminals. These indoor air quality connections let you integrate humidifiers, dehumidifiers, and ventilators with the thermostat’s control logic.

IAQ device wiring (page 5)
Device Wiring Notes
Steam humidifier R to U1, U1 to humidifier [7]
Bypass flow-through humidifier R jumpered to U1, U1 to humidifier [7]
Whole house dehumidifier R to U1, U1 to dehumidifier [7]
A/C with low-speed fan R jumpered to U1, U1 to dehumidification terminal [7, 8]
Whole house powered ventilator R to U1, U1 to ventilator [7]
Non-powered ventilator R jumpered to U1, U1 to ventilator [7]

Notes: “[7] Terminals are normally open dry contacts.” “[8] Equipment must include dehumidification terminal for low-speed fan.”

Installer Setup Functions

Pages 7-10 list 70+ VisionPRO TH8000 installer setup functions (0120-0710). The most critical are:

Key installer setup functions (pages 7-10)
Function Setting Options
0170 System type 1-12 (conventional, heat pump, multistage)
0180 Fan control (heating) 0 Gas/Oil, 1 Electric furnace
0190 Changeover valve (O/B) 0 Cooling, 1 Heating
0220 1st stage compressor cycle rate 3 CPH recommended (1, 2, 4, 5, 6)
0240 1st stage heat cycle rate 5 Gas/oil <90%, 1 Steam, 3 Hot water, 9 Electric
0300 Manual/Auto changeover 0 Manual, 1 Auto
0371 IAQ device on U1/U1 0 None, 1 Humidification, 2 Dehumidification, 3 Ventilation
0400 Ventilation control 0-4 (off, on, lockouts)
0580 Compressor protection 5 minutes recommended (0-5)
0600 Heat temperature range stop 90°F max (40-89°F)
0610 Cool temperature range stop 50°F min (51-99°F)

The full list includes date/time (0120-0160), schedule format (0160), energy saving (0165), heat pump type (0173), auxiliary heat (0200), fossil fuel kit (0210), 2nd/3rd stage cycle rates (0230, 0260), backlight (0280), auto changeover deadband (0310), temperature display (0320), daylight savings (0330), remote sensor (0340), dual fuel control (0345-0347), heat pump lockouts (0350-0360), humidification control (0372-0374), dehumidification (0379-0394), ventilation (0401-0432), filter reminders (0500-0520), UV lamp (0520), adaptive recovery (0530), program periods (0540), clock format (0640), extended fan timer (0650-0660), keypad lock (0670), temperature control (0680-0690), display offset (0700-0701), and reset (0710).

Each VisionPRO TH8000 installer setup function controls a specific aspect of system operation. The manual prints factory defaults in bold throughout pages 7-10, so you can see at a glance which settings need changing for your particular installation.

Installer System Test

Pages 10-11 describe seven system tests. Enter test mode by pressing the system button repeatedly until “Test” appears.

System test numbers (pages 10-11)
Test System Status
1 Cooling 0 Off, 1 Compressor/fan on, 2 2nd stage
2 Fan 0 Off, 1 On
3 Heating 0 Off, 1 1st stage, 2 2nd stage, 3 3rd stage
4 Emergency heating 0 Off, 1 On
5 Humidifier 0 Off, 1 On
6 Dehumidifier 0 Off, 1 On
7 Ventilator 0 Off, 1 On

The manual warns: “CAUTION: EQUIPMENT DAMAGE HAZARD. Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.”

Pages 11-12 explain special functions. Auto Changeover (0300) requires heat/cool settings at least 2°F apart (5°F if dehumidification is on).

Remote Sensor (0340) can display outdoor temperature or use a remote indoor sensor. Adaptive Intelligent Recovery (0530) learns how long the system takes to reach setpoints. Compressor Protection (0580) forces a wait before restart.

Dehumidification (0380) on TH8321 models can lower temperature up to 3°F below the cool setting. Heat pump control (0350-0360) sets compressor and auxiliary lockout temperatures. Ventilation (0400-0432) can be locked out by outdoor temperature. Dehumidification Away Mode (0390-0394) controls humidity when the home is unoccupied.

TH8000 Series Specifications and Accessories

Page 12 lists TH8000 Series specifications:

  • Temperature ranges: Heat 40° to 90°F (4.5° to 32°C), Cool 50° to 99°F (10° to 37°C)
  • Operating ambient: 0° to 120°F (-18° to 48.9°C)
  • Shipping: -30° to 150°F (-34° to 66°C)
  • Humidity: 5% to 90% (non-condensing)
  • Dimensions: 4-9/16 in. H x 6 in. W x 1-3/8 in. D (116 mm H x 152 mm W x 35 mm D)
Electrical ratings (page 12)
Terminal Voltage (50/60Hz) Running Current
W 20-30 Vac / 750 mV DC 0.02-1.0 A / 100 mA DC
W2 20-30 Vac 0.02-0.6 A
Y 20-30 Vac 0.02-1.0 A
Y2 20-30 Vac 0.02-0.6 A
E/Aux 20-30 Vac 0.02-1.0 A
O/B 20-30 Vac 0.02-0.6 A
L 20-30 Vac 0.02-0.6 A
U1/U1 20-30 Vac 0.02-0.6 A

Accessories include outdoor sensor C7089U1006, remote indoor sensor C7189U1005, discharge air sensor C7735A1000, ventilators ER200B2006/HR200B1005, fresh air damper EARD6, humidifiers HE265A1007/HM512W1005, and cover plate 32003796-001.

FAQ

How do I find the model number?

“(Pull thermostat from wallplate and turn over to find model number)”. Page 1 lists TH8321U1097 for this TH8321U installation.

What’s the difference between conventional and heat pump terminals?

Heat pump systems add E/Aux (auxiliary/emergency heat), L (heat pump reset/monitor), and O/B (changeover valve). Conventional systems use W/W2 for heat stages and Y/Y2 for cooling stages.

How do I wire an outdoor sensor?

Connect to S1/S2 terminals. In installer setup, set function 0340 to 1 (outdoor sensor display only), 2 (outdoor sensor for control with lockouts), or 4 (discharge air sensor for desert humidity control).

What does the L terminal do?

The L terminal provides “Heat pump reset (powered continuously when System is set to Em Heat; system monitor when set to Heat, Cool or Off).” The wiring notes make the common connection mandatory when this terminal is used.

How do I set up dehumidification?

Set function 0371 to 2 for dehumidification control. For TH8321 models, function 0380 can activate cooling to reduce humidity by up to 3°F below the cool setting. For whole-house dehumidification, wire to U1/U1 and set function 0379 to 3.

What’s the compressor protection setting?

Function 0580 defaults to 5 minutes. The manual states: “Forces the compressor to wait a few minutes before restarting, to prevent damage. During this time, the message ‘Wait’ is displayed.” Options are 0-5 minutes.