Honeywell CT3600 Programmable Thermostat Owner's Guide

Honeywell CT3600 Programmable Thermostat Owner’s Guide

The Honeywell CT3600 is a seven-day programmable thermostat for low-voltage heating and cooling equipment, rated for 20 to 30 Vac and powered by three AA alkaline batteries. Each day carries four periods, Morning, Daytime, Evening and Night, and the unit ships with a preset schedule plus Smart Response, which starts the equipment early so the house reaches the setpoint on time. The owner’s guide, document 69-0939-1, is a 32-page manual covering mounting, wiring, programming and seven troubleshooting entries.


Download / Preview Manual

32 pages, English only, revision 11-97. The file carries the compatibility chart, the wiring diagrams for conventional and single-stage heat pump systems, the installer setup table and the full troubleshooting guide.


Honeywell CT3600 Product Specifications

Specification Details
Brand Honeywell
Model CT3600
Product Type Seven Day Programmable Heat and/or Cool thermostat and wallplate
Voltage Low voltage, 20 to 30 Vac
Power Three AA alkaline batteries
Program Periods Four per day: Morning, Daytime, Evening, Night
Preset Heat 70 / 62 / 70 / 62 °F
Preset Cool 78 / 85 / 78 / 82 °F
Setpoint Range Heat 40 to 90 °F; Cool 45 to 99 °F
Document 69-0939-1 (printed 69-0939—1), 32 pages, revision 11-97
Warranty One year limited, excluding battery

Frequently asked questions

Q: What batteries does the CT3600 use?

A: Three AA alkaline batteries, fitted on the wallplate with the positive terminals facing up. REPL BAT flashes for one to two months before the cells run out, and the guide recommends replacing them once a year. New batteries inserted within 20 to 30 seconds of removing the old ones keep the current time.

Q: Why is the display blank?

A: The guide names two causes: batteries that are dead or incorrectly installed, and a thermostat that is not mounted and latched on the wallplate. Check that the batteries are fresh and correctly oriented, then press the lower edge of the case until it latches.

Q: Why won’t the temperature setting change?

A: The thermostat stops at its setpoint limits. Heating runs from 40 to 90 °F and cooling from 45 to 99 °F. The display flashes during programming when a limit has been reached.

Q: What is Smart Response?

A: It calculates when to start the heating or cooling so the house reaches the programmed temperature at the programmed time, using air temperature and wall temperature, and adjusts its estimate each day from experience. The installer setup can switch it to conventional recovery, which starts the system at the programmed time instead.

Q: Will the CT3600 work with a heat pump or a multistage system?

A: A single-stage heat pump is listed as compatible, and the wiring diagrams include a four-wire heat pump connection using either O or B for changeover. Multistage heat pumps and other multistage equipment are listed as not compatible; the guide adds that six or more wires, not counting clock wires, usually mean a multistage system, in which case the product should be returned. Millivolt systems and 120/240 volt line-voltage systems are also excluded.

 